  • Hello! I am an AI chatbot trained to assist you with the ALLEGION RC-04 ISONAS Reader Controll User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Black
Orange
Yellow
Red
White
Blue
Green
Brown
Cat5e/6 to Switch
4750 Walnut Street Suite 110
Boulder, CO 80301
www.isonas.com
Date:
1-23-18
Drawn By:
David Tamarchenko
Version:
1.00.00
Dwg No: Sheet
1
of
1
RC-04.PwrSup.EDK.Strike.BaterryBackUpCalc
BackEMF Diode Assembly
(install close to strike)
12VDC Electric
Strike
Isolate and insulate
wires not used
WHT
YLW
BLK
ORG
NO
NC
COM
GND
V+
WHT
YLW
BLK
ORG
NO
NC
COM
GND
V+
WHT
YLW
BLK
ORG
NO
NC
COM
GND
V+
*Power
Supply with
Battery
Charging
Circuit
-BAT
+BAT
+12VDC
-12VDC
-BAT
+BAT
+12VDC
-12VDC
*Power
Supply with
Battery
Charging
Circuit
-BAT
+BAT
+12VDC
-12VDC
12VDC Battery12VDC Battery 12VDC Battery12VDC Battery
Example back up battery calculation using peak values
to determine minimum run time on battery back up:
RC-04 .170 A
EDK .010 A
E. Strike .320 A
Total Current .500 A
2 x 7.5AH Batteries in Parallel = 15 Amp Hours
15 AH/.500 A = 30 Hours of operation on Back Up
*Please note that a minimum of .75 Amp rated power
supply would be needed for this application.
/