Xeon Tower/5U Rackmount Server
®
AP1700
Users Manual
with 533MHz FSB support
ii ASUS AP1700
Disclaimer/Copyrights
No part of this manual, including the products and software described in it, may be
reproduced, transmitted, transcribed, stored in a retrieval system, or translated into
any language in any form or by any means, except documentation kept by the purchaser
for backup purposes, without the express written permission of ASUSTeK COMPUTER
INC. (“ASUS”).
ASUS PROVIDES THIS MANUAL “AS IS” WITHOUT WARRANTY OF ANY KIND,
EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. IN NO EVENT SHALL ASUS, ITS DIRECTORS,
OFFICERS, EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT, SPECIAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR
LOSS OF PROFITS, LOSS OF BUSINESS, LOSS OF USE OR DATA,
INTERRUPTION OF BUSINESS AND THE LIKE), EVEN IF ASUS HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY
DEFECT OR ERROR IN THIS MANUAL OR PRODUCT.
Product warranty or service will not be extended if: (1) the product is repaired, modified
or altered, unless such repair, modification of alteration is authorized in writing by
ASUS; or (2) the serial number of the product is defaced or missing.
Products and corporate names appearing in this manual may or may not be registered
trademarks or copyrights of their respective companies, and are used only for
identification or explanation and to the owners’ benefit, without intent to infringe.
The product name and revision number are both printed on the product itself. Manual
revisions are released for each product design represented by the digit before and
after the period of the manual revision number. Manual updates are represented by
the third digit in the manual revision number.
For previous or updated manuals, BIOS, drivers, or product release information, contact
ASUS at http://www.asus.com.tw or through any of the means indicated on the following
page.
SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE
FURNISHED FOR INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE
AT ANY TIME WITHOUT NOTICE, AND SHOULD NOT BE CONSTRUED AS A
COMMITMENT BY ASUS. ASUS ASSUMES NO RESPONSIBILITY OR LIABILITY
FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS MANUAL,
INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT.
Copyright © 2003 ASUSTeK COMPUTER INC. All Rights Reserved.
Product Name: AP1700
Manual Revision: Revised Edition V2 E1182
Release Date: March 2003
Users Manual iii
ASUS Contact Information
ASUSTeK COMPUTER INC. (Asia-Pacific)
Address: 150 Li-Te Road, Peitou, Taipei, Taiwan 112
General Tel: +886-2-2894-3447
General Fax: +886-2-2894-3449
General Email: [email protected]
Technical Support
MB/Others (Tel): +886-2-2890-7121 (English)
Notebook (Tel): +886-2-2890-7122 (English)
Desktop/Server (Tel): +886-2-2890-7123 (English)
Support Fax: +886-2-2890-7698
Web Site: www.asus.com.tw
ASUS COMPUTER INTERNATIONAL (America)
Address: 44370 Nobel Drive, Fremont, CA 94538, USA
General Fax: +1-510-608-4555
General Email: [email protected]
Technical Support
Support Fax: +1-510-608-4555
General Support: +1-502-933-8713
Web Site: www.asus.com
Support Email: [email protected]
ASUS COMPUTER GmbH (Germany & Austria)
Address: Harkortstr. 25, 40880 Ratingen, BRD, Germany
General Fax: +49-2102-442066
General Email: [email protected] (for marketing requests only)
Technical Support
Support Hotline: MB/Others: +49-2102-9599-0
Notebook (Tel): +49-2102-9599-10
Support Fax: +49-2102-9599-11
Support (Email): www.asuscom.de/de/support (for online support)
Web Site: www.asuscom.de
iv ASUS AP1700
FCC/CDC Statements
Federal Communications Commission
This device complies with FCC Rules Part 15. Operation is subject to the
following two conditions:
This device may not cause harmful interference, and
This device must accept any interference received including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
manufacturers instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment to an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
WARNING! The use of shielded cables for connection of the monitor
to the graphics card is required to assure compliance with FCC
regulations. Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void the user’s
authority to operate this equipment.
Canadian Department of Communications
This digital apparatus does not exceed the Class B limits for radio noise
emissions from digital apparatus set out in the Radio Interference Regulations
of the Canadian Department of Communications.
This class B digital apparatus complies with Canadian ICES-003.
Users Manual v
Contents
Disclaimer/Copyrights ....................................................................... ii
ASUS Contact Information ............................................................... iii
FCC/CDC Statements........................................................................ iv
Safety Precautions........................................................................... vii
Electrical Safety ............................................................................... vii
Operation Safety .............................................................................. vii
Introduction
About this guide............................................................ I-1
Audience ........................................................................................... I-2
Contents............................................................................................ I-2
Conventions ..................................................................................... I-3
References........................................................................................ I-3
System Package Contents .............................................................. I-4
Chapter 1: System Overview
System Overview ......................................................... 1-1
1.1 System Features.................................................................... 1-2
1.2 Front Panel Features............................................................. 1-3
1.3 Rear Panel Features .............................................................. 1-4
1.4 Internal Features.................................................................... 1-5
1.5 LED Table ............................................................................... 1-6
Chapter 2: Hardware Reference
Hardware Reference .................................................... 2-1
2.1 Removing and installing chassis cover .............................. 2-2
2.2 Motherboard Placement........................................................ 2-4
2.3 Central Processing Unit........................................................ 2-5
2.4 System Memory ..................................................................... 2-9
2.5 Fixed Device Bays ............................................................... 2-12
2.6 Hard Disk Drives.................................................................. 2-18
vi ASUS AP1700
2.7 Screwless Expansion Card Slot......................................... 2-20
2.8 Long Card Support Guide................................................... 2-21
2.9 RAID Card............................................................................. 2-22
2.10 Hard Drive Blower ............................................................... 2-23
2.11 Chassis Fan ......................................................................... 2-24
2.12 Connecting Cables .............................................................. 2-25
2.13 SCSI Backplane ................................................................... 2-26
Appendix A: Optional chassis roller-wheel
Chassis Roller-wheel Installation ..................................................A-2
Appendix B: Power Modules
Redundant Power Modules ............................................................A-4
Appendix C: Troubleshooting
Troubleshooting ..............................................................................A-9
Users Manual vii
Safety Precautions
Electrical Safety
Operation Safety
This product is equipped with a three-wire power cable and plug
for the user’s safety. Use the power cable with a properly grounded
electrical outlet to avoid electrical shock.
CAUTION
Any mechanical operation on this server must be conducted by
certified or experienced engineers.
Before operating the server, carefully read all the manuals
included with the server package.
Before using the server, make sure all cables are correctly
connected and the power cables are not damaged. If any damage
is detected, contact your dealer as soon as possible.
To avoid short circuits, keep paper clips, screws, and staples
away from connectors, slots, sockets and circuitry.
Avoid dust, humidity, and temperature extremes. Place the server
on a stable surface.
IMPORTANT
IMPORTANT
Before installing or removing signal cables, ensure that the power
cables for the system unit and all attached devices are unplugged.
To prevent electrical shock hazard, disconnect the power cable from
the electrical outlet before relocating the system.
When adding or removing any additional devices to or from the
system, ensure that the power cables for the devices are unplugged
before the signal cables are connected. If possible, disconnect all
power cables from the existing system before you add a device.
If the power supply is broken, do not try to fix it by yourself. Contact
an authorized dealer.
viii ASUS AP1700
Users Manual I-1
Introduction
About this guide
“About This Guide” introduces the contents
of this document. This part includes the
target audience, chapter description, and
conventions used. It also lists other sources
of information that are not contained in this
manual.
I-2 ASUS AP1700
Audience
Contents
This guide contains the following parts:
1. Introduction: About this guide
This part introduces the contents of this document. It includes the target
audience, chapter description, and conventions used. It also lists other
sources of information that are not contained in this manual.
2. Chapter 1: System overview
This chapter describes the general features of the AP1700 system
server. It includes sections on front panel and rear panel specifications.
3. Chapter 2: Hardware setup
This chapter lists the hardware setup procedures that you have to
perform when installing system components.
4. Appendix A: Optional Chassis Roller-wheels
This appendix contains the installation procedure for the optional
chassis roller-wheel units for the AP1700 server system.
5. Appendix B: Redundant Power Modules
This appendix contains detailed hardware operation and specifications
of the AP1700 redundant power modules.
6. Appendix C: Troubleshooting
This appendix lists the common problems that you may encounter while
using the AP1700 server. It lists the possible causes of the
problems and offers solutions. You may refer to this part and try to
solve simple problems before calling customer support.
This user guide is intended for system integrators, and experienced users
with at least basic knowledge of configuring an entry-level server.
Users Manual I-3
Conventions
Symbols
To make sure that you perform certain tasks properly, take note of the
following symbols used throughout this manual.
WARNING: Information to prevent injury to yourself when
trying to complete a task.
CAUTION: Information to prevent damage to the components
when trying to complete a task.
IMPORTANT: Information that you MUST follow to complete
a task.
NOTE: Tips and information to aid in completing a task.
References
Refer to the following sources for additional information and for product
and software updates.
1. ASUS PR-DLS533 Motherboard Users Manual
This manual contains detailed information about the PR-DLS533
motherboard.
2. ASUS Websites
The ASUS websites worldwide provide updated information on ASUS
hardware and softare products. The ASUS websites are listed in the
ASUS Contact Information on page v.
3. Optional Documentation
Your product package may include optional documentation such
as a CD-ROM manual, warranty flyers, and others that may have
been added by your dealer. NOTE: These documents are not part
of the standard server package.
I-4 ASUS AP1700
System Package Contents
The following checklist enumerates the components included in the
standard system package.
1) ASUS AS-35 Tower/5U Rackmount chassis
2) ASUS PR-DLS533 motherboard
3) 500W+500W redundant power supply
4) Backplane board (BP6LS-AS35)
5) CD-ROM drive (1 piece)
6) Floppy disk drive (1 piece)
7) Special heatsink with fan assembly (2 sets)
8) Hot swap SCSI hard disk drive tray (6 units)
9) AC power cord (2 pieces)
10) Support CD that includes drivers, utilities, ASUS System
Monitoring Agent (ASMA) with the ASUS Server Web-based
Management (ASWM)
11) Trend Micro Server Protect anti-virus software full user version CD
enterprise edition
12) Motherboard user guide
13) System user guide
14) LSI SCSI controller user guide
15) ASMS (ASMA + ASWM) user guide
16) chassis roller wheels (4 sets)
17) Keys x 2
18) Screws and labels
Optional:
1) ASUS AS-35 5U rackmount rail kit
2) LSI MegaRAID 320-0 Zero channel RAID card
If any of the above items is missing, contact your dealer.
Users Manual 1-1
Chapter 1
System Overview
This chapter describes the general features of
the AP1700 system server. It includes sections
on front panel, rear panel and internal
specifications.
1-2 ASUS AP1700
1.1 System Features
The ASUS AP1700 server is a stylish server system featuring the
ASUS PR-DLS533 motherboard. The server supports the Intel
®
Xeon
processor in a 604-pin socket, and includes the latest I/O, LAN, and
video technologies through the chipsets embedded on the
motherboard.
The following are highlights of the servers many features:
Chassis: Pedestal or rackmount 5U with removable front door
bezel and chassis foot stand or roller-wheels.
Motherboard: ASUS PR-DLS533
Chipset: RCC Grand Champion LE Server 3.1 (GCLE), RCC
Champion South Bridge 5.0 (CSB5), RCC Champion I/O Bridge
2.0 (CIOB-X2)
Memory: Supports six 184-pin DDR DIMM sockets, PC2100/
PC1600 registered ECC DDR DIMMs, 128MB to 12GB system
memory.
Processor: Support for two Intel
®
Xeon
TM
processor up to 2.8
GHz+ frequency.
Network Controller: Intel
®
82544GC Gigabit Ethernet controller,
Intel
®
82540EM Gigabit Ethernet controller
Drive Controller: LSI 53C1030/64-bit/100MHz Dual Ultra-320
channels. Two UltraDMA 100 IDE channels.
Graphics: ATI RAGE-XL PCI with 8MB PC-100 SDRAM video
memory
Onboard IO: 1 X PS/2 mouse port, 1 X PS/2 keyboard slot, 1 X
serial ports, 1 X 15-pin VGA port, 1 X floppy drive slot, 2 X IDE
ports, 4 X USB ports, 2 X RJ-45 LAN port, 2 X 68-pin SCSI
connectors
Special IO: IPMB connector, SM-Bus
Expansion: 5 X 64-bit 3V PCI-X slots, 1 X 32-bit/33Mhz 5V PCI
slot
Device Bays: 6 X hot-swap trays for SCA SCSI hard drives, 3 X
5.25 inch bay, 1 X floppy disk drive bay.
Power Supply: 500W redundant power supply.
Hardware Monitors: Voltage, temperature, Automatic System
Restart (ASR), fan speed.
Users Manual 1-3
1.2 Front Panel Features
The front panel allows easy access to the hard disk drives. The power
and reset buttons, LED indicators, optical drive, floppy drive and two
USB connectors are also located on the front panel. For future
installation of 5.25 devices, there are two drive bays available. The
front panel of the server is protected by a door and lock for added
security.
6 SCA SCSI Hard
Drive Swap Trays
CD-ROM Drive
Drive Activity LED
3.5” Floppy Drive
Reset Button
Power Button
2 USB PortsFront Door Lock
2 empty 5.25” bays
Power LED
HDD Access LED
Message LED
Drive Status LED
For more detailed information of each LED display, refer to
“1.5 LED Table” on page 1-6.
1-4 ASUS AP1700
1.3 Rear Panel Features
The server rear panel includes the connectors, the system devices,
a chassis lock and six full-length expansion cards slot. The following
shows the features on the rear side of the server.
High Density 68-pin
SCSI Connector
AC Power IN Connector
AC Power Status LED
12 cm chassis fan
6 Full-Length PCI Slots
Chassis Lock
PS/2 mouse port
PS/2 keyboard port
2 x USB ports
Serial port
Parallel port
VGA port
Dual Gigabit
LAN ports
You may secure the chassis lock with an additional padlock
or other security device for added server system security.
Users Manual 1-5
1.4 Internal Features
The standard components inside the server include the motherboard,
power supply, floppy and CD-ROM drives, and cables. The picture
below shows the standard components of the server.
1. Redundant power
supply cage
2. 6 x DDR DIMM sockets
3. 2 x IDE cable
4. 5
1/4” CD-ROM drive
5. HDD hot swap modules
1
4
2
7
5
10
9
3
8
6. 5 x 64 bit 3V PCI-X slots
7. CPU sockets
8. Internal 68-pin SCSI cable
9. PCI Long Card support guide
10. 12 cm hot swap
module blower
11. PR-DLS533 motherboard
11
6
1-6 ASUS AP1700
1.5 LED Table
The following table describes the LED display found on the front panel
and rear panel of the AP1700 server system.
Only RAID cards with SAF-TE feature is enabled with HDD
rebuilding function.
LED
Display Description
Green
HDD insert and
Power status is good
Drive Status
LED
Red
HDD Fail
Red blinking
HDD rebuilding (RAID
card SAF-TE* function)
Blinking
HDD Read/Write data
Drive Activity
LED
ON
System power ON
Power LED
Blinking
Suspend Mode
OFF
No activity
HDD Access
LED
Blinking
Read/Write data in HDD
OFF
Normal/No incoming event
Message
LED
Blinking
ASMS indicate HW
monitor event
*SCSI Access Fault - Tolerant Enclosure
Icon
1
2
3
4
1
1
2
3
4
Users Manual 2-1
Chapter 2
Hardware Setup
This chapter lists the hardware setup
procedures that you have to perform when
installing system components.
2-2 ASUS AP1700
2.1 Removing and installing chassis cover
The chassis is designed for easy assembly and disassembly, making the
installation of internal components very convenient.
2.1.1 Removing the chassis cover
1. Loosen the two thumb screws that secure the side cover.
2. Slide the chassis cover for about half an inch toward the rear until it is
disengaged from the chassis.
1
2
Half-inch gap
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58

Asus AP1700 User manual

Category
Servers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI