c) To exit the memory record function, push the
" REC " button at least 2 seconds continuously. The
display will revert back to the current reading.
4-2 Type K/J thermometer
1)Power on by pressing the " Power On/Off Button " ( 3-3,
Fig. 1 ) , the meter's default function is " Sound
level meter with auto range "
Press the " Mode Button " ( 3-6, Fig. 1 ) once will
enter to " Thermometer ( type K, type J )
* Press the " Mode Button " ( 3-6, Fig. 1 ) once again
will revert to " Sound level meter "
2)Under the Thermometer mode, if press the / Button "℃℉
( 3-7, Fig. 1 ) can select the Temp. unit to or , in℃℉
the same time LCD will show the or symbol.℃℉
3)The Thermometer is default to " Type K " function,
if intend to change the " Type K " to " Type J ",
please refer the
5-1 Thermometer, type K. type J selection, page 16.
4)Connect the plug of the Temp. probe ( optional type K
probe, TP-01, TP-02A, TP-03, TP-04 ) into the
" Temperature input socket " ( 3-10, Fig. 1 )
* When insert the probe plug into the temp. input
socket should take care to observe the correct
polarity.
5)Data Hold
Same as page 11
6)Data Record ( Max., Min. reading )
Same as page 11
12