Page 1 Model: DSQR110BN/DSQR110ORB
For Customer Support please email
[email protected], or call
(888)930-8528. Please provide the bath fan model number found
on the front of this manual when contacting Customer Support.
GENERAL SAFETY INFORMATION AND WARNINGS
For your safety and to ensure proper performance of the unit, it is very important to read
these instructions carefully before installation. Failure to comply with the instructions
contained herein could result in personal injury or property damage. We recommend that
you keep this booklet for future reference. All units should be installed by a licensed
electrician.
1. Electrical service supply must be 120V 60Hz.
2. Wires from the house power supply to the unit should not be smaller than size 14 AWG.
3. Follow all local safety and electrical codes, as well as requirements for NEC (National Electrical Code) and
OSHA (Occupational Safety and Health Act).
4. This unit must be properly grounded.
5. This unit is equipped with a built-in thermal cut-off for safety and to prolong the life of the motor.
6. Always disconnect the power supply prior to servicing the fan, motor or junction box.
7. Do not bend or kink the power wires.
8. Do not install where the air temperature will exceed 40
◦
C (104
◦
F).
9. This ventilating fan is approved for use over a bathtub or shower when installed in a GFCI-protected circuit.
10. Do not use to exhaust hazardous or explosive vapors.
11. Do not install in a cooking area.
12. Use this unit in the manner intended by the manufacturer. If you have any questions, please call Customer
Support at (888) 930-8528.
13. Installation work must be carried out by qualified person(s) in accordance with all local and safety codes,
including the rules for fire-rated construction.
14. Exercise care not to damage existing wiring when cutting or drilling into walls or ceilings.
15. Fans should always be vented to the exterior/outside of the home.
16. Do not use this fan with any solid-state control device.
17. Prior to servicing or cleaning this unit, shut off power supply at the panel and lock to prevent the power
from being turned on. If the panel cannot be locked, clearly mark the panel with a warning tag not to turn
on the power.
18. Ductwork should be installed in as straight a line as possible, with minimum bends.
19. Ductwork size must be a minimum of the discharge and should not be reduced.
20. The fan is intended to be mounted at least 7 feet (2.1m) above the floor.