FEATURES
• Humidity-sensingfanshutsoffaerbathroomissteam-free
• Motion-activatednightlightfunctionsindarkenvironments
andshutsofftwominutesaermotionceases
• Fanisultra-quiet
• Brightfluorescentlightforgeneralbathroomillumination
TYPICALINSTALLATION
FAN HOUSING
ROOF
DUCT
OR
EXTERIOR WALL
SPECIFICATIONS
• Grilldimensions”x”x”cmxcmxcm
• Housingdimensions/”x⁄”x”
cmxcmxcm
• Ductdiameter”cm
• Soundoutputsones
• AirowCFM
• ExhaustfanspeedRPM
• Weightlbskg
• ElectricalratingV/Hz/A/Wfanonly
V/Hz/A/Wfanandlights
• Assembledweightlbskg
RequirestwoWWequivalentGUbase
CFLbulbsandoneWCintermediatebase
incandescentbulbnotincluded
Make sure the vent/duct is venting outward
and not up into the ceiling.
ISO|
fanbodywithreflector
suspensionbracketI
longwoodscrew
actualsize
shortmachinescrew
actualsize
longmachinescrew
actualsize
switch
suspensionbracketII suspensionbracketIII
metalrimandglass
bell
ceilingplate
INTHEBOX
NOT INCLUDED: Tools required for assembly and lightbulbs.
ISO|
SAFETYINFORMATION
READ AND SAVE THESE INSTRUCTIONS
Please read and understand the entire manual before attempting
to assemble, operate, or install the product.
• Alwaysdisconnectthepowersupplypriortoservicingthefan
motororjunctionbox
• Installationworkmustbecarriedoutbyaqualifiedpersonsin
accordancetoalllocalandsafetycodesincludingtherulesfor
fire-ratedconstruction
• Followalllocalbuildingsafetyandelectricalcodesaswell
asNECNationalElectricalCodeandOSHAOccupational
SafetyandHealthAct
• ElectricServicesupplymustbevoltshertz
• Thisunitmustbeproperlygrounded
• Donotbendorkinkthepowerwires
• Exercisecaretonotdamageexistingwiringwhencutting
ordrillingintowallsorceilings
• Sufficientairsupplyisrequiredforpropercombustion
andexhaustionofgasesthroughthechimneyflue
orfuelburningequipmenttopreventback-draing
*SeethestandardsofNFPANationalFireProtection
AssociationandASHRAEAmericanSocietyfor
HeatingRefrigerationandAirConditioningEngineers
andthelocalbuildingcodeauthorities
• WARNING–Toreducetheriskoffireorelectricshock–do
notusethisfanwithanysolidstatecontroldevicesuchasa
remotecontroldimmerswitchorcertaintimersMechanical
timersarenotsolidstatedevices
• Donotinstallinacookingarea
• CAUTION–Forgeneralventilatinguseonly–donotuseto
exhausthazardousorexplosivevapors
• Fansshouldalwaysbeventedtotheexteriorincompliance
withlocalcodes
• DonotinstallinaceilingwithinsulationgreaterthanR
• Ductworkshouldbeinstalledinastraightline
withminimalbends
• Ductworksizemustbethesamesizeasthedischarge
andshouldnotbereducedReducingtheductsizemay
increasefannoise
• Priortoservicingorcleaningthisunitshutoffpowersupply
atthepanelandlocktopreventthepowerfrombeingturned
onIfthepanelcannotbelockedclearlymarkthepanelwitha
warningtagtopreventthepowerfrombeingturnedon
• Usethisunitinthemannerintendedbythemanufacturer
• WARNING–TOREDUCETHERISKOFFIREELECTRIC
SHOCKORINJURYTOPERSONSOBSERVETHE
FOLLOWING
aUsethisunitonlyinthemannerintendedbythemanufacturer
Ifyouhavequestionscontactthemanufacturer
bBeforeservicingorcleaningunitswitchpoweroffatservice
panelandlocktheservicedisconnectingmeanstoprevent
powerfrombeingswitchedonaccidentallyWhentheservice
disconnectingmeanscannotbelockedsecurelyfastena
prominentwarningdevicesuchasatagtotheservicepanel
• Ifyouhaveanyquestionspleasecallcustomerserviceat
QUIRKY
ISO|
PREPARATION
Before beginning assembly of product, make sure all parts are
present. Compare parts with package contents list and hardware
contents lists. If any part is missing or damaged, do not attempt
to assemble the product.
Estimated assembly time: one hour.
Tools required for assembly (not included): drywall saw, ”
Phillips head drill bit, electric drill, stud finder,  drive Phillips
head screwdriver, standard face plate for light switch.
WARNING: Turn off electricity at breaker box before
beginning installation.
• Carefullyremoveunitfromcarton
• Checkareaaboveinstallationlocationtobesurethatwiring
canruntotheplannedlocationductworkcanberunand
theareaissufficientforproperventilationIfductcannot
berunawayfromceilingorthereisnoductconsultwitha
professionalbeforeinstalling
• Inspectductworkandwiringbeforeproceedingwithinstallation
• Beforeinstallationmakesurethereisanaccessibleareafor
futuremaintenanceaccess
• Youmayneedthehelpofasecondpersontoinstallthisfan
onepersonontheatticsideandtheoneonthebathroomside
Note: Installation may vary depending on how the previous bath
fan was installed. Supplies necessary for the installation of your
bath fan are not all included; however, most should be available
at your local home improvement or hardware store.
The hole for installation is not sized to the fan unit – use the
following dimensions so that the Iso ceiling panel will rest flush
against the ceiling.
DIMENSIONREQUIREMENTS
Ceiling Opening
(L)
Ceiling Opening
(W)
Ceiling Opening
(H)
incm incm incm
FANWIRINGDIAGRAM
WIRINGINSTRUCTIONS
LIGHT HOUSING
FAN HOUSING CONTROLLER
PCBA
UPTOWATTS
UPTOWATTS
AUTOMATICTERMINALSWITCH
MOTOR
GREENWIRETOGROUND
CAPACITOR
FORLONG
LIFEOFFAN
WHITEWIRETONEUTRAL
BLACKWIRETOLIVE
WARNING: Wiring must comply with applicable electrical codes.
Turn OFF power before removing or installing wire nuts.
WARNING: Copper to copper only. Do not use aluminium wire.
CAUTION: Accessory part (wires nuts) should meet installation
instructions below.
NOTE: The wire nut is reusable on solid wire of the same wire
gage or smaller, do not reuse the wire nut on stranded wires.
• Stripwires/˝–/˝cmcm
• Takebothwires
fromwallandfromnewswitch
andtwisttogethersecurely
Insertsecuredwiresintowirenut
• Verifywiresarefullyinserted
intothewirenut
Further wiring instructions are included
in the Installation Instructions section
NOTE – Important wire information: Maximum temperature
rating FCvolts maximum for building wire and
 volts maximum for building wire and  volts maximum
in signs and lighting fixtures.
The acceptable wire range includes: Solid:  AWG
WIRE NUT
PRODUCT
WIRES
HOUSE
WIRES
BLACK WIRE
TO LIVE
WHITE WIRE
TO NEUTRAL
GREEN WIRE
TO GROUND
ISO|
Using a drywall saw, cut a ”x”cmxcm
opening in the ceiling for the panel.
a) Make sure the hole you cut is between two () studs –
this can be done using a stud finder.
INSTALLATIONINSTRUCTIONS
BEFOREINSTALLATION
Turn off power source. Review all safety precautions.
PLEASE NOTE:
• IfinstallingIsoinalocationthatcanbeaccessedfromabove
theinstallationlocationviaatticorcrawlspacefollowthe
“NewConstruction”instructions
• IfinstallingIsoinalocationthatCANNOTbeaccessed
fromabovetheinstallationlocation–followthe“Existing
Construction”instructions
It is required to have an exhaust duct that leads outside and not
into the ceiling or attic as this could cause water damage.
The ventilation fan is UL approved for use over a bathtub or
shower when installed in a GFCI protected circuit. Do not use
fans over a bathtub or shower that are not approved for that
application and marked accordingly.
PLEASE NOTE: the fan is to be installed at least  feet
 meters) above floor level.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
• Installationworkandelectricalwiringmustbedonebyqualified
personsinaccordancewithallapplicablecodesandstandards
includingfire-ratedconstruction
• Sufficientairisneededforpropercombustionandexhausting
ofgasesthroughthefluechimneyoffuelburningequipment
topreventbackdraingFollowtheheatingequipment
manufacturer’sguidelineandsafetystandardssuchasthose
publishedbytheNationalFireProtectionAssociationNFPA
andtheAmericanSocietyforHeatingRefrigerationandAir
ConditioningEngineersASHRAEandthelocalcodeauthorities
• Whencuttingordrillingintowallorceilingdonotdamage
electricalwiringandotherhiddenutilities
• Ductedfansmustalwaysbeventedtotheoutdoors
• Ifthisunitistobeinstalledoveratuborshoweritmustbemarked
asappropriatefortheapplicationandbeconnectedtoaGFCI
GroundFaultCircuitInterrupter–protectedbranchcircuit
OR
Insert the suspension brackets into the fan body – there are
suspension brackets provided:
• SuspensionbracketIattachestotherailontheside
oftheunit
• SuspensionbracketIIwillslideintosuspensionbracketI
Makesuretheyslidefreelywithnoobstruction
• SuspensionbracketIIIattachestotheothersideoftheunit
wheretheexhaustportis
NOTE: If the ceiling joists are less than ” (cmapart,
the suspension brackets need to be shortened with a dremel
or angle grinder before inserting into unit.
NEWCONSTRUCTION
ISO|
Insert the fan body into the ceiling cut out making sure to align
the duct connector with the fan body.
IMPORTANT: The bottom edge of the fan body MUST BE /”
 cm) ABOVE THE CEILING (it should not hang down or be
level with the ceiling).
NOTE: Duct/outlet adapter can be removed for easier
installation through the ceiling opening.
To mount the fan body to ceiling joists – screw in the long
wood screws (six in total) into the suspension brackets
connected to the joist.
Hardware used: Long wood screw x
CAUTION: Dimension “B” should allow for thickness of ceiling
board used in your application. Do not flush mount to joist.
FAN BODY
FAN
JOIST
JOIST
0.7CEILING
BOARD
DIMENSION B
CEILING
BOARD
CEILING BOARD
JOIST
BRACKET
Using wire nuts (provided), connect house wires to ventilating
fan wires: black to black; white to white; green to green;
(refer to wiring diagram on page ).
CAUTION: If your house wires do not match these colors,
you must determine what each house wire represents
before connecting and you may need to consult an electrical
contractor to determine this safely.
Attach the ceiling panel (contains the infrared motion sensor,
light sensor, and humidity sensor):
• Pinchfirstmountingspringonpanelandinsertintonarrow
rectangularslotsinsidethefanhousingnexttothefanmotor
Connect the ”cm duct to vent duct (in ceiling)
and secure it with duct tape or clamps (not included).
Finish ceiling work.
Connect the main PCB via the plastic connector on the end
of rainbow flat cable to the PCB board on the ceiling panel.
WIRE NUT
PRODUCT
WIRES
HOUSE
WIRES
ISO|
Pinch second mounting spring and give the ceiling panel
aslight push to click into place. Ceiling panel should be
mounted flush against the ceiling.
 Push bell into center of ceiling panel to install. Give it a slight
tug to make sure it does not pop off. It should be able to
rotatefreely.
 Carefully install two WWequivalent) GUCFL
bulbs (not included) into the sockets and one (WC
incandescent bulb (not included) into the black center socket.
Remove existing fan and fan housing.
EXISTINGCONSTRUCTION
Make sure the existing hole is at least ”x”
cmxcmbut smaller than ”x”cmxcm
Cut into the ceiling (about ”cm] wide to fit drill bit – refer
to diagram) to extend suspension brackets and mount to stud
(use a stud finder if necessary).
NOTE: Save drywall piece to patch holes cut for suspension
brackets aer completing step in New Construction.
Refer to Steps  in “New Construction” to
completeinstallation.
 Attach metal trim glass dish to bell with the four () short
machine screws (provided).
Hardware used: Short machine screws x 
 Turn on electricity at breaker box aer completing installation.
HOLE FOR FAN
JOIST
JOIST


”
”
ISO|
WALLSWITCHSPECIFICATIONS
The wall switch has two sliding switches: one for the fan and
one for the night light. There is also a button for the main lights.
The fan and night light sliding switches have three positions:
off/auto/on. In “auto” mode, the fan turns on when the humidity
sensor senses sufficient humidity, and the nightlight turns on
when the motion detector detects motion in a dark environment.
The humidity and motion detectors are built into the ceiling
component. In “on” mode, the fan and nightlight remain on even
if the room is not humid and no motion is detected. The main light
button clicks on and off; it has no “auto” mode.
Switch (Fan) ON/OFF/AUTO
Switch (Night Light) ON/OFF/AUTO
Button (Main light) ON/OFF
TOINSTALLTHEWALLSWITCH
Turn off the power to the switch at the main circuit breaker
orfuse panel.
Unscrew and remove the switch plate; then use a voltage
tester to make sure that the circuit is dead.
Unscrew the switch from the electrical box and pull it out
with the wires still attached.
• Twoorthreewireswillbeattachedtotheswitch
–anincominghotwirewhichisblack
–aneutralwirewhichiswhite
– andpotentiallyagroundingwirewhichisgreen
orbarecopper
• Theremaybeotherwiresintheswitchboxbutyouareonly
dealingwiththeonesconnecteddirectlytotheswitch
• Youmayfindawhitewirethathasblacktapeonitconnectedto
theswitchThistapeindicatesthatthewhitewireisbeingused
asablackorcoloredwireintheswitchlegsoitisnotneutral
Compare your new switch with the one you’re replacing
to find the corresponding locations for the wires.
To connect wires to the new switch:
• Locatetheblackhotwireinyourswitchboxandattachtothe
blackwireinthenewswitchusingawirenutprovided
• Locatethewhiteneutralwireinyourswitchboxandattach
tothewhitewireinthenewswitchusingaquickconnector
• Locatethegroundgreenorcopperwireinyourswitchbox
andattachtothegroundwireinthenewswitchusingawirenut
orquickconnector
6 Gently push the new, wired switch back into the switch box and
screw the switch plate in place using the provided machine screws.
Hardware used: CC Long machine screw x 
7 Attach faceplate (not included) over switch plate.
8 Turn on the power.
NOTE: The wall switch communicates wirelessly with the
fan/ light unit. Therefore, no wires are run from the switch
to the fan/light unit in the ceiling.
ISO|
WARNINGDISCONNECTPOWERSUPPLY
BEFORESERVICING
SEESAFETYINFORMATIONBEFOREPROCEEDING
ROUTINEMAINTENANCESHOULDBEDONEAT
LEASTONCEAYEAR
CAUTION
• Neverusesolventsthinnerorharshchemicalsfor
cleaningthefan
• Donotallowwatertoenterthemotor
• DonotimmerseplasticpartsinwateroverFC
Unscrew the four () screws and carefully remove the glass
and metal assembly.
Remove the  light bulbs and change as necessary.
Remove the bell by pulling down with both hands.
CAREANDMAINTENANCE TODISASSEMBLE
ISO|
Pull down on ceiling panel with both hands until it separates
from ceiling but is still suspended by the springs.
5 Disconnect the rainbow colored cable from the ceiling
panel by pulling on the connector.
Remove the ceiling panel by squeezing the springs
and pulling down.
Remove dust and dirt from the fan housing
with a vacuum cleaner.
Dampen cloth with dish detergent, wipe the fan housing and
dry with a cloth. DO NOT USE abrasive cloth, steel wool pads,
or scouring pads.
Replace the ceiling panel by following steps  under
installation inNew Construction”.
TOCLEAN
TOCHANGEALIGHTBULB
Turn the fan light off.
Unscrew the four () screws and carefully remove
the glass and metal assembly.
Remove the necessary light bulb and discard.
Screw in appropriate light bulb (see Installation
step for proper light bulb specifications).
Reattach glass and metal assembly with the four ( screws.
ISO|
TROUBLESHOOTINGTIPS
PROBLEM POSSIBLECAUSES WHATTODO
THEREISAVISIBLE
GAPBETWEENTHE
CEILINGPANELAND
CEILING
The hole is smaller than
”x”cmxcm
Remove panel (refer to Care & Maintenance) and check to see
if fan was installed properly
Bottom edge of fan is
less than ⁄” cm) from
ceiling surface
Remove panel (refer to Care & Maintenance) and check to see
if fan was installed properly
THEFANSEEMS
LOUDERTHANIT
SHOULDBE
CFM too high CFMfanisdesignedforroomsuptosqsqm
Damper (exhaust port)
not working properly or
isdamaged.
Check exhaust flap to ensure it is opening and closing properly.
If the exhaust fan has become damaged, please call Customer
Service
Bend in duct too close
tofandischarge.
Be sure you do not have any sharp bends in duct closer
than”cm) to the fan discharge
Fan body not securely
attached.
Be sure the fan is securely attached to your ceiling joists
Fan duct is being obstructed
at some point (including end
of duct)
Check the air duct to ensure the duct is not restricting air flow
Fan may be clogged with
dust or debris
Refer to Care & Maintenance section for cleaning instructions
THEFANISNOT
CLEARINGTHE
HUMIDITYOUT
OFTHEROOM
Insufficient intake airflow
within room.
The fan is not able to draw air out of the room without enough
airow to draw from have a door or window slightly ajar or open
to allow airflow
Insufficient CFM Be sure the CFM rating on the fan matches the requirements
for your room size. NOTE: If the fan clears steam from the room
within 15 minutes aer the shower has been turned off, the fan is
operating properly
Dust/dirt is clogging
fan intake
Refer to Care and Maintenance instructions
Duct may not be connected
tofan properly
Check air duct and fan connection to ensure that there
is a proper seal
ISO|
PROBLEM POSSIBLECAUSES WHATTODO
THEFANISNOT
TURNINGONIN
AUTO”MODE
Humidity sensor PCB is not
connected
Please revisit the instruction manual and verify the wiring
of the wall switch and fan are properly connected
Sensor PCB was connected
while power was on
With sensor PCB still connected, restart power source
to the unit
NIGHTLIGHTNOT
TURNINGON Sensor is obstructed Using a damp cloth or rag, clean off the fan’s faceplate,
including the small half sphere sensor
Bulb is burnt out Check and replace night light bulb
Night light sensor is not
registering movement
Using a damp cloth or rag, clean off fan’s faceplate, including the
small half sphere sensor. Make sure the hanging part of the unit
is not obstructing the PIR sensor from detecting movement
THEREGULARLIGHT
ISNOTTURNINGON Bulb is burnt out Check and replace light bulb using the instructions on page 
Wiring could have
become loose
Check switch box wiring to ensure wiring is correct
THEFANISNOT
TURNINGOFF Humidity in the room is
still in target range for
fantostay activated
Turn off manually or wait for fan to re-calibrate
WATERDAMAGE/
LEAKINGONCEILING The vent/duct has
not been installed
correctly
Make sure the vent/duct is venting outward and not up
into the ceiling
ISO|
LIMITEDTHREEYEARWARRANTY
QUIRKYINC“QUIRKY”ORIGINALPURCHASE
PRODUCTWARRANTY
Quirky warrants to the original purchaser (“Purchaser”) of
thisQuirky product, for the period of three () years following
the date on which Purchaser purchases the product, that the
product shall be free of defects in design, assembly, material,
orworkmanship.
Quirky will refund or replace, at its option, any defective product
free of charge.
In order to qualify for this warranty, the Purchaser must provide
the defective product and a copy of the original receipt of
purchase to Quirky for inspection. The receipt of purchase must
indicate the product purchased, price paid, date of purchase, and
name of merchant.
To request service under this warranty, contact Quirky
at QUIRKY or questions@quirky.com and a Quirky
representative will provide instruction on how to proceed.
This warranty shall be null and void if Quirky determines that
the product has been improperly installed, altered or tampered
with in any way. This warranty does not protect against normal
use, wear and tear, or damage due to abuse.
THIS WARRANTY CONTAINS THE SOLE WARRANTY OF
QUIRKY. THERE ARE NO OTHER WARRANTIES, EXPRESSED
OR IMPLIED, INCLUDING THE IMPLIED WARRANTY OR
CONDITION OF QUALITY, MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE, AND SUCH IMPLIED
WARRANTIES, IF ANY, ARE LIMITED IN DURATION TO THE
TERM OF THIS WARRANTY. IN NO EVENT SHALL QUIRKY BE
LIABLE FOR INCIDENTAL, SPECIAL, DIRECT, INDIRECT OR
CONSEQUENTIAL DAMAGES SUCH AS, BUT NOT LIMITED TO,
LOST BUSINESS OR PROFITS ARISING OUT OF THE SALE OR
USE OF ANY QUIRKY PRODUCT, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES.
Some jurisdictions do not allow exclusions or limitations on
implied warranties or incidental, consequential or other damages,
so the above exclusions and limitations may not apply to you.
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: () this device may not
cause harmful interference, and () this device must accept any
interference received, including interference that may cause
undesired operation.
Caution: Changes or modifications not expressly approved
by the party responsible for compliance could void the user’s
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part
 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician
for help.
This device complies with industry Canada licence exempt RSS
standard(s). Operation is subject to the following two conditions:
() this device may not cause interference, and () this device
must accept any interference, including interference that may
cause undesired operation of the device.
COMPLIANCE
ISO|
ULWARNINGSTATEMENT
Section  – General
READ AND SAVE THESE INSTRUCTIONS
 Preventariskoffireelectricshockorinjurytopersons
bycleaningandusermaintenancesuchaslubrication
 Unplugordisconnecttheappliancefromthepowersupply
beforeservicing
WARNING To Reduce The Risk Of Fire Or Electric
Shock, Do Not Use This Fan With Any Solid State Speed
ControlDevice.
 WARNINGTOREDUCETHERISKOFFIREELECTRIC
SHOCKORINJURYTOPERSONSOBSERVETHE
FOLLOWING
aUsethisunitonlyinthemannerintendedbythe
manufacturerIfyouhavequestionscontactthe
manufacturer
bBeforeservicingorcleaningunitswitchpoweroffat
servicepanelandlocktheservicedisconnectingmeansto
preventpowerfrombeingswitchedonaccidentallyWhen
theservicedisconnectingmeanscannotbelockedsecurely
fastenaprominentwarningdevicesuchasatagtothe
servicepanel
 CAUTIONForGeneralVentilatingUseOnlyDoNotUse
ToExhaustHazardousOrExplosiveMaterialsAndVapors
Additionalsafetyinformationisincludedintheinstruction
manualonpage
ULWARNINGSTATEMENT
Section A – Installation Instructions
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire rated construction.
b) Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent back draing. Follow the heating
equipment manufacturer’s guideline and safety standards
such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) – protected
branch circuit.
Additional installation instructions are included in the instruction
manual on pages .
ULWARNINGSTATEMENT
Section B – User Servicing Instructions
All user servicing instructions are included in the instruction
manual on pages 
ISO|
CUSTOMERSUPPORT
For service and support, email us at questions@quirky.com
orcallQUIRKY
RINSISOX|rev
For service questions, contact Quirky at 1-866-578-4759.
For sales inquiries, contact Sylvane at 1-800-934-9194.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Quirky iso User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI