PROGRAMMING OZONE CONTROL VALVE CONTINUED
PROGRAMMING OZONE CONTROL VALVE
SETTING THE TIME
NOTES
1) Press NEXT and DOWN simultaneously
and release. Press NEXT and DOWN
simultaneously for 5 seconds and
release. If the screen in Step 2 does not
appear, the lock on the valve is activated.
To unlock, press DOWN, NEXT, UP
and CLOCK in sequence, then press NEXT
and DOWN simultaneously for 5 seconds
and release. Press NEXT and DOWN
simultaneously for 5 seconds and release.
2)
Press CLOCK once. Press UP or DOWN
until your hour is correct and the correct
AM/PM is shown. Press NEXT to select
the minutes (select UP or DOWN until the
minutes are correct). Select CLOCK to get
back to the main screen.
1) Set the time of day for backwashing to
happen while you are sleeping.
2) The Relay Actuation Time is when the
Ozonator is turned on, set the time for
15 minutes for the system to activate.
The entire process will take 37 minutes,
the unit needs to turn on and turn o,
leaving adequate time to vent.
6)
SET
FILTERING
REGEN
Use UP or DOWN to select FILTERING
REGEN. Press NEXT to go to Step 3. Press
REGEN to exit Conguration Settings.
3)
SET TIME
BACKWASH
MIN
1 10
SET TIME
MIN
15:00
SET TIME
MIN
37:00
Use UP or DOWN to adjust backwash
time (we suggest 10 minutes). Press NEXT
to go to Step 4. Press REGEN to return to
previous step.
4)
SET
SET
BRINE
BRINE
MIN
2 30
2 dn
Step 4 alternates between the two
displays shown. Use UP or DOWN to adjust
brine time (we suggest 30 minutes). Press
NEXT to go to Step 5. Press REGEN to
return to previous step.
5)
SET
BACKWASH
MIN
3 off
Use UP or DOWN to set RINSE to OFF. Press
NEXT to go to Step 7. Press REGEN to return
to previous step.
7)
SET
RINSE
4 off
Use UP or DOWN to set FILL to OFF. Press
NEXT to go to Step 8. Press REGEN to return
to previous step.
8)
SET
GAL
FILL
5 off
Use UP or DOWN to set REGEN to OFF.
Press NEXT to go to Step 9. Press REGEN to
return to previous step.
9)
SET
REGEN
off
Step 9 alternates between the two
displays shown. Use UP or DOWN to set
RELAY 1 to ON. Press NEXT to go to Step
10. Press REGEN to return to previous step.
10)
SET
SET
rL
y
1
0ff
minute after the air/ozone draw starts.
Use UP or DOWN to set RELAY 1 to 15.
Press NEXT to go to Step 11. Press REGEN
to return to previous step.
11)
Use UP or DOWN to set 2nd backwash to
OFF. Press NEXT to go to Step 6. Press
REGEN to return to previous step.
Step 10 sets Relay Actuation Time, when
the EOG unit turns on. Relay activates after
the beginning of regeneration cycle and
then deactivates after a set period of time.
The start of the regeneration is dened
as the rst backwash cycle or DN brine cycle,
whichever comes rst. Set for 15 minutes
or 1 minute after the time set in Step 3. This
means the relay will turn on the EOG unit 1
REMAINING
Step 11 indicates the length of time the
EOG unit is activated. Use UP or DOWN to
adjust the amount of time to 37:00
minutes. Press NEXT to go to Step 12.
Press REGEN to return to previous step.
12)
SET
SET
rL
y
2
0ff
Step 12 alternates between the two
displays shown. Use UP or DOWN to set
RELAY 2 to OFF. Press NEXT to EXIT
Conguration Settings. Press REGEN to
return to previous step.