Notice technique complète sur www.atim.com
FRQIG_ARM-IOD-LP
Page4/4
– Put the STRAP 1 (ON) and the STRAP 2 (ON)
– Put back the battery
– The LED is flashing rapidly
– Disconnect the battery
For initializing the modem (frequency and modem address selection):
– Disconnect the battery
– Run down the remaining voltage in shorting circuit the + and the - of the battery connector
– Remove the STRAP 2 (OFF)
– Put the STRAP 1 (ON)
– Put back the battery
– The LED is flashing: 1s ON / 1s OFF, during 35s
– If the radio modem receive a modbus frame on a frequency from its frequency table (usable radio frequency : channel 1; 3; 5;
7; 9; D; F; see table frequency, Ch2,3)), it records the selected frequency and the sent address. There is no answer to request, so
the LED is flashing, 200ms ON and 2s OFF.
– After 35s, the modem takes the default configuration and the LED is lighting: 200ms ON / 5s OFF
Default configuration:
– Radio frequency: channel 1
– Modbus address: last octet of the serial number
ARM-IO configuration by webpage:
–Select in the radio tab: « radio baud rate »: 9600bps
– Select in the setup tab: « Wake up sleeping slave »
ARM-IO configuration by AT command:
– Register S04 Hexadecimal Value: 20
– Register S09 Hexadecimal Value: 12
– Register S36 Hexadecimal Value: AF
– Register S37 Hexadecimal Value: 00
5. CONFIGURATION EN MODE MIROIR
The modem configuration can be made in manufactory.
For erasing the modem configuration:
– Disconnect the battery
– Run down the remaining voltage in shorting circuit the + and the - of the battery connector
– Put the STRAP 1 (ON) and the STRAP 2 (ON)
– Put back the battery
– The LED is flashing rapidly
– Disconnect the battery
For initializing the modem (modem address and frequency selection):
– Disconnect the battery
– Run down the remaining voltage in shorting circuit the + and the - of the battery connector
– Put the STRAP 1 (ON) and the STRAP 2 (ON)
– Connect the logical input INP1 to the ground according to the cycle time desired:
- INP1 disconnected : cycle time 1mn
- INP1 connected to the ground: cycle time 15mn
– Put back the battery
– La LED is flashing rapidly: 200ms ON 200ms OFF
– The modem is initialized in master mirror mode with the default address corresponding to the last octet of the MAC address.
– Disconnect the battery
– Run down the remaining voltage in shorting circuit the + and the - of the battery connector
– Configure the slave ARM-D Modem or slave ARM-X mirror mode. Local address=ARM-IO-LP. Destination address= ARM-IOD-LP
– Take off the STRAP 2 (OFF)
– Put back the battery
– The ARM-IO-LP will automatically search the slave modem. The LED lights as soon as the emission of a radio frame and the
answer to its request on a channel.