Siemens 6ES7142-6BG00-0BB0 Equipment Manual

Category
Networking
Type
Equipment Manual

This manual is also suitable for

SIMATIC
ET 200eco PN
I/O device digital outputs
DQ 8x24VDC/0.5A M12
-L 8xM12
(6ES7142-6BG00-0BB0)
Equipment Manual
07/2020
A5E46570894
-AA
Preface
ET 200eco PN M12-L
Documentation Guide
1
Product overview
2
Wiring
3
Parameters/address space
4
Interrupts/diagnostics
alarms
5
Technical specifications
6
Dimension drawing
A
A5E46570894-AA
07/2020 Subject to change
Copyright © Siemens AG 2020.
All rights reserved
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
Equipment Manual, 07/2020, A5E46570894-AA
3
Preface
Purpose of the documentation
This equipment manual supplements the ET 200eco PN M12-L Distributed I/O System
(https://support.industry.siemens.com/cs/ww/en/view/109778292
) system manual. Functions
that relate in general to the distributed I/O devices ET 200eco PN M12-L are described in this
system manual.
The information provided in this equipment manual and in the system manual and the
function manuals supports you in commissioning the ET 200eco PN M12-L distributed I/O
devices.
Conventions
Also observe notes marked as follows:
Note
A note contains important information:
On the product described in the documentation
On handling the product
On the part of the documentation to which particular attention is paid
Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement and continuously maintain a holistic, state-of-the-art industrial
security concept. Siemensproducts and solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems,
machines and networks. Such systems, machines and components should only be connected
to an enterprise network or the internet if and to the extent such a connection is necessary
and only when appropriate security measures (e.g. firewalls and/or network segmentation)
are in place.
For additional information on industrial security measures that may be implemented, please
visit (https://www.siemens.com/industrialsecurity
).
Siemens' products and solutions undergo continuous development to make them more
secure. Siemens strongly recommends that product updates are applied as soon as they are
available and that the latest product versions are used. Use of product versions that are no
longer supported, and failure to apply the latest updates may increase customers' exposure to
cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed visit (https://www.siemens.com/industrialsecurity
).
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
4 Equipment Manual, 07/2020, A5E46570894-AA
Table of contents
Preface ................................................................................................................................................... 3
1 ET 200eco PN M12-L Documentation Guide .......................................................................................... 5
2 Product overview ................................................................................................................................... 9
2.1 Properties ............................................................................................................................ 9
2.2 Operator controls and display elements ............................................................................. 11
3 Wiring .................................................................................................................................................. 12
3.1 Terminal and block diagram ............................................................................................... 12
3.2 Pin assignment .................................................................................................................. 14
4 Parameters/address space ................................................................................................................... 18
4.1 Parameters ........................................................................................................................ 18
4.2 Explanation of the parameters ........................................................................................... 19
4.3 Address space .................................................................................................................... 20
5 Interrupts/diagnostics alarms .............................................................................................................. 24
5.1 Status and error displays .................................................................................................... 24
5.2 Interrupts .......................................................................................................................... 27
5.3 Alarms ............................................................................................................................... 28
5.3.1 Diagnostics alarms ............................................................................................................. 28
5.3.2 Maintenance events .......................................................................................................... 29
6 Technical specifications ....................................................................................................................... 30
A Dimension drawing ............................................................................................................................. 35
A.1 Dimension drawing............................................................................................................ 35
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
Equipment Manual, 07/2020, A5E46570894-AA
5
ET 200eco PN M12-L Documentation Guide
1
The documentation for the SIMATIC ET 200eco PN M12-L distributed I/O system is arranged
into three areas. This arrangement enables you to access the specific content you require.
Basic information
The system manual describes in detail the configuration, installation, wiring and
commissioning of the SIMATIC ET 200eco PN M12-L distributed I/O system. The STEP 7 online
help supports you in the configuration and programming.
Device information
Product manuals contain a compact description of the module-specific information, such as
properties, interfaces, wiring diagrams, display and operator control elements and technical
specifications.
General information
The function manuals contain detailed descriptions on general topics relating to the SIMATIC
ET 200eco PN M12-L distributed I/O system, e.g. diagnostics, communication and PROFINET.
You can download the documentation free of charge from the Internet
(https://support.industry.siemens.com/cs/de/en/view/109742718
).
ET 200eco PN M12-L Documentation Guide
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
6 Equipment Manual, 07/2020, A5E46570894-AA
"mySupport"
With "mySupport", your personal workspace, you make the best out of your Industry Online
Support.
In "mySupport", you can save filters, favorites and tags, request CAx data and compile your
personal library in the Documentation area. In addition, your data is already filled out in
support requests and you can get an overview of your current requests at any time.
You must register once to use the full functionality of "mySupport".
You can find "mySupport" on the Internet (https://support.industry.siemens.com/My/ww/en
).
Application examples
The application examples support you with various tools and examples for solving your
automation tasks. Solutions are shown in interplay with multiple components in the system -
separated from the focus on individual products.
You will find the application examples on the Internet
(https://support.industry.siemens.com/sc/ww/en/sc/2054
).
TIA Selection Tool
With the TIA Selection Tool, you can select, configure and order devices for Totally Integrated
Automation (TIA).
This tool is the successor of the SIMATIC Selection Tool and combines the known
configurators for automation technology into one tool.
With the TIA Selection Tool, you can generate a complete order list from your product
selection or product configuration.
You can find the TIA Selection Tool on the Internet
(https://w3.siemens.com/mcms/topics/en/simatic/tia-selection-tool
).
ET 200eco PN M12-L Documentation Guide
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
Equipment Manual, 07/2020, A5E46570894-AA
7
SIMATIC Automation Tool
You can use the SIMATIC Automation Tool to perform commissioning and maintenance
activities simultaneously on various SIMATIC S7 stations as a bulk operation independent of
TIA Portal.
The SIMATIC Automation Tool provides a multitude of functions:
Scanning of a PROFINET/Ethernet system network and identification of all connected CPUs
Address assignment (IP, subnet, gateway) and station name (PROFINET device) to a CPU
Transfer of the date and the PG/PC time converted to UTC time to the module
Program download to CPU
RUN/STOP mode switchover
CPU localization by means of LED flashing
Reading out of CPU error information
Reading the CPU diagnostics buffer
Reset to factory settings
Firmware update of the CPU and connected modules
You can find the SIMATIC Automation Tool on the Internet
(https://support.industry.siemens.com/cs/ww/en/view/98161300
).
PRONETA
SIEMENS PRONETA (PROFINET network analysis) allows you to analyze the plant network
during commissioning. PRONETA features two core functions:
The topology overview automatically scans the PROFINET and all connected components.
The IO check is a fast test of the wiring and the module configuration of a system.
You can find SIEMENS PRONETA on the Internet
(https://support.industry.siemens.com/cs/ww/en/view/67460624
).
ET 200eco PN M12-L Documentation Guide
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
8 Equipment Manual, 07/2020, A5E46570894-AA
SINETPLAN
SINETPLAN, the Siemens Network Planner, supports you in planning automation systems and
networks based on PROFINET. The tool facilitates professional and predictive dimensioning of
your PROFINET installation as early as in the planning stage. In addition, SINETPLAN supports
you during network optimization and helps you to exploit network resources optimally and to
plan reserves. This helps to prevent problems in commissioning or failures during productive
operation even in advance of a planned operation. This increases the availability of the
production plant and helps improve operational safety.
The advantages at a glance
Network optimization thanks to port-specific calculation of the network load
Increased production availability thanks to online scan and verification of existing systems
Transparency before commissioning through importing and simulation of existing STEP 7
projects
Efficiency through securing existing investments in the long term and the optimal use of
resources
You can find SINETPLAN on the Internet (https://www.siemens.com/sinetplan
).
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
Equipment Manual, 07/2020, A5E46570894-AA
9
Product overview
2
2.1 Properties
Article number
6ES7142-6BG00-0BB0
View of the I/O device
Figure 2-1 View of the I/O device DQ 8x24VDC/0.5A M12-L 8xM12
Product overview
2.1 Properties
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
10 Equipment Manual, 07/2020, A5E46570894-AA
Properties
The I/O device has the following technical properties:
8 digital outputs
M12 sockets for connection of actuators
Rated supply voltage 24 V DC
Rated load voltage 24 V DC
Integrated switch with 2 ports
Single and dual assignment of the sockets
Configurable diagnostics can be set for each channel
Output current per output 0.5 A
Total current max. 4 A (per I/O device)
Suitable for solenoid valves, DC contactors, and indicator lights
Dimensions 45 x 200 mm
The I/O device supports the following functions:
Firmware update
Identification and maintenance data I&M0 to I&M3
Isochronous mode
Value status (Quality Information)
Module-internal Shared Output (MSO)
Shared Device
Accessories
The following components are included in the I/O device package:
Identification labels
Other components
The following component can be ordered as spare part:
Identification labels
The following components can be ordered as accessories:
Mounting rail
Connectors and cables
M12 sealing cap
See also
You can find additional information on the accessories in the ET 200eco PN M12-L distributed
I/O system system manual.
Product overview
2.2 Operator controls and display elements
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
Equipment Manual, 07/2020, A5E46570894-AA
11
2.2 Operator controls and display elements
The figure below shows the operator controls and display elements of the
DQ 8x24VDC/0.5A M12-L 8xM12 I/O device.
PN/MF (LAN): Sockets for connecting PROFINET
RN/NS: RUN/network status LED
ER/MS: ERROR/module status LED
MT/IO: MAINT/IO status LED
PWR: Power LED for load voltage 2L+
P1 LK/P2 LK: LINK port status LEDs
LED displays 0 to 7 for channel status/channel error
X10 to X17: Sockets for the output signal
X80: Connector for infeed of supply and load voltage
X81: Socket for loop-through of the supply and load voltage
Figure 2-2 Operator controls and display elements
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
12 Equipment Manual, 07/2020, A5E46570894-AA
Wiring
3
3.1 Terminal and block diagram
The figure below shows an example of the pin assignment of signal outputs with single and
dual assignment of the sockets.
Wiring
3.1 Terminal and block diagram
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
Equipment Manual, 07/2020, A5E46570894-AA
13
Bus interface with integrated 2-port switch
1L+
Supply voltage 1L+ (non-switched)
Monitoring
1M
Ground 1M (non-switched)
DQ circuit
2L+
Load voltage 2L+ (switched)
Internal supply voltage
2M
Ground 2M (switched)
Output (dual assignment of the socket)
DQn
Output signal
Output (single assignment of socket)
RN/NS
RUN/network status LED (green)
Output (single assignment of socket)
ER/MS
ERROR/module status LED (red)
X10 to X17
Channels 0 to 7
MT/IO
MAINT/IO status LED (yellow)
X80
Infeed of supply and load voltage
P1 LK
LINK port 1 LED (green)
X81
Loop-through of supply and load voltage
P2 LK
LINK port 2 LED (green)
X1 P1R PROFINET interface X1 port 1 DQ Channel status/channel error LED
(green/red)
X1 P2R
PROFINET interface X1 port 2
PWR
LED load voltage 2L+ (green)
Figure 3-1 Terminal and block diagram
Wiring
3.2 Pin assignment
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
14 Equipment Manual, 07/2020, A5E46570894-AA
3.2 Pin assignment
Terminal assignment PROFINET connector
The following table shows the pin assignment of the PROFINET connector.
Table 3- 1 Pin assignment of the PROFINET connector, port 1 and 2
Pin
Assignment of the core
color of the PROFINET
cable
Assignment Front view of the connectors
Assignment X1 P1R
1
Yellow
TXP
2
White
RXP
3
Orange
TXN
4
Blue
RXN
Thread
Functional earth FE
Assignment X1 P2R
1
Yellow
RXP
2
White
TXP
3
Orange
RXN
4
Blue
TXN
Thread
Functional earth FE
Wiring
3.2 Pin assignment
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
Equipment Manual, 07/2020, A5E46570894-AA
15
Pin assignment of sockets for digital outputs
The table below shows the pin assignment of the 8 sockets for the connection of the digital
outputs.
Table 3- 2 Pin assignment for digital outputs
Pin
Assignment
Front view of the sockets
X10 to X17 - sockets for digital outputs X10, X12,
X14, X16
X11, X13,
X15, X17
1
-
2
Connector X10: Output signal DQ
1
*
Connector X11: Not assigned
Connector X12: Output signal DQ
3*
Connector X13: Not assigned
Connector X14: Output signal DQ
5*
Connector X15: Not assigned
Connector X16: Output signal DQ
7*
Connector X17: Not assigned
3
Ground 2M
4
Connector X10: Output signal DQ
0
Connector X11: Output signal DQ1*
Connector X12: Output signal DQ
2
Connector X13: Output signal DQ
3*
Connector X14: Output signal DQ
4
Connector X15: Output signal DQ
5*
Connector X16: Output signal DQ
6
Connector X17: Output signal DQ7*
5
Functional earth FE
* Note the assignment of the output signals to the respective sockets in the foll
owing section "Dual
assignment of the sockets".
Dual assignment of the sockets
There are two output signals at the sockets X10, X12, X14 and X16 of the I/O device. Pin 2 of
the respective socket is assigned an additional output signal.
Note
Dual or sin
gle assignment of sockets
You can select the dual and single assignment of sockets as desir
ed.
Note that the output signals DQ
1, DQ3, DQ5 and DQ7
are each parallel to the sockets X10/X11,
X12/X13, X14/X15, X16/X17.
Wiring
3.2 Pin assignment
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
16 Equipment Manual, 07/2020, A5E46570894-AA
The following graphic shows the assignment of the output signals to the respective sockets
with dual or single assignment.
Figure 3-2 Assignment of output signals with dual or single assignment of sockets
Pin assignment of the connector for infeed of the supply voltage (M12 L-coded)
The table below shows the pin assignment of the M12 L-coded connector for infeed of the
supply voltage.
Table 3- 3 Pin assignment of the supply voltage connector
Pin
Assignment of the
core color of the
power cable
Assignment
Front view of the
connector
X80 - connector (POWER input)
1
Brown
Supply voltage 1L+ (non-switched)
2
White
Ground 2M (switched)
3
Blue
Ground 1M (non-switched)
4
Black
Load voltage 2L+ (switched)
Wiring
3.2 Pin assignment
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
Equipment Manual, 07/2020, A5E46570894-AA
17
Pin assignment of the socket for loop-through of the supply voltage (M12 L-coded)
The table below shows the pin assignment of the M12 L-coded socket for loop-through of the
supply voltage.
Table 3- 4 Pin assignment of the supply voltage socket
Pin
Assignment of the
core color of the
power cable
Assignment
Front view of the
socket
X81 - socket (POWER output)
1
Brown
Supply voltage 1L+ (non-switched)
2
White
Ground 2M (switched)
3
Blue
Ground 1M (non-switched)
4
Black
Load voltage 2L+ (switched)
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
18 Equipment Manual, 07/2020, A5E46570894-AA
Parameters/address space
4
4.1 Parameters
The table below shows the parameters for the I/O device DQ 8x24VDC/0.5A M12-L 8xM12.
Table 4- 1 Configurable parameters and their defaults (GSD file)
Parameters Value range Default
Scope with configu-
ration software, e.g.
STEP 7 (TIA Portal)
Diagnostics: Undervoltage 1L+
Disable
Enable
Disable
Channel
Diagnostics: Missing 2L+
Disable
Enable
Disable
Channel
Diagnostics: Short-circuit
Disable
Enable
Disable
Channel
Diagnostics: Wire break
Disable
Enable
Disable
Channel
Reaction to CPU STOP
Shutdown
Keep last value
Output substitute value 1
Shutdown
Channel
Parameters/address space
4.2 Explanation of the parameters
I/O device digital outputs DQ 8x24VDC/0.5A M12-L 8xM12 (6ES7142-6BG00-0BB0)
Equipment Manual, 07/2020, A5E46570894-AA
19
4.2 Explanation of the parameters
Diagnostics: Undervoltage 1L+
Enabling of diagnostics for insufficient supply voltage 1L+.
Diagnostics: Undervoltage 1L+ triggers the "Undervoltage" maintenance event. You can find
more information in section Maintenance events (Page 29).
Diagnostics: Missing 2L+
Enabling of the diagnostics for missing or insufficient load voltage 2L+.
Diagnostics: Short-circuit
Enabling of the diagnostics for short-circuit of the output to ground.
Diagnostics: Wire break
Enabling of diagnostics when the line between the actuator and the I/O device is interrupted.
Reaction to CPU STOP
With this parameter, you set the reaction of the digital outputs of the I/O device after a CPU
STOP:
Shutdown: The digital output is de-energized.
Keep last value: The last value of the digital output remains activated.
Output substitute value 1: The I/O device outputs the substitute value "1".
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Siemens 6ES7142-6BG00-0BB0 Equipment Manual

Category
Networking
Type
Equipment Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI