Line run length Feet X 0.07 # per foot
PLUS Rise from bottom of
keg to outlet of faucet
Feet X 0.5 # per foot
+
MINUS Fall from bottom of
keg to outlet of faucet
Feet X 0.5 # per foot
-
PLUS minimum 24” choker + 6.0
If using Kyees tower ADD + 4.8
If using Kyees Chill Pak ADD + 4.0
If using bent tube assembly
in tower
ADD +
3.0
Total initial resistance
=
If total initial resistance is 20 # or greater *, you have the Applied Keg Pressure and length of choker
tube. If initial resistance is less than 20 #, add additional choker as below.
Minimum Pressure * 20 #
Minus Total initial resistance as calculated above
-
Equals initial additional resistance to add
=
Times 4 x 4
Equals initial number of inches choker tube to add
=
Round up the number of initial inches choker tube to
add to the next 1” segment
Plus minimum choker length + 24"
Total amount of choker hose to use in the run with
20 # Applied Keg Pressure
=
* If your altitude is above 2,000 feet, add 1 # per 2000 feet or portion
thereof to the minimum pressure stated above.
Beer system pressure and choker
calculator
For Blended Gas
0.00
0.00
0.00
0.00
0.00
0.00
-- Choose One --
-- Choose One --
6.00
20.00
6.00
14.00
56.00
56
80
0.00
RESET
PRINT
-- Choose One --
Yes