WIRING DIAGRAM
FOR 120V & 240V ENVIRON II WITH
THE SMARTSTAT™ / EASYSTAT™ USING A JUNCTION BOX
ELECTRICAL ROUGH-IN
MOUNTING HARDWARE
4” x 4” DEEP TWO GANG
SQUARE BOX SUPPLIED
BY CONTRACTOR
SINGLE GANG MUD RING
(PLASTER RING) SUPPLIED
BY CONTRACTOR
HOT
THERMOSTAT
SENSOR WIRE
(LOW VOLTAGE)
FROM POWER SOURCE 120V & 240V
PB112C-GA
FRONT BASE
12
1. ENSURE THE SYSTEM IS GROUNDED
2. MAT HAS NO POLARITY
3. WIRE FROM THERMOSTAT TO JUNCTION BOX SHOULD
BE SIZED ACCORDING TO LOCAL ELECTRICAL CODE
REQUIREMENTS.
HOT (240V) or
NEUTRAL (120V)
6/17/99
- 1/2" CONDUIT
FOR WIRING
1/2" CONDUIT
FOR FLOOR
SENSOR
CONDUIT TO
POWER SOURCE
WARMING SYSTEM
4" x 4" DEEP TWO GANG
SQUARE BOX WITH SINGLE
GANG MUD RING FOR
CONNECTION TO THERMOSTAT
Free Design Service • 24/7 Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.com
20011 9/2012
HOUSE GROUND
RED
BLACK
RED
BLACK
Load
S
L2 (N)
L1 (L)
SENSOR
PROBE
ITEM #: TH115-AF-GA ITEM #: TH114-AF-GA
SMARTSTAT™ / EASYSTAT™
JUNCTION BOX
WITH COVER
WHITE OR
YELLOW (120V)
OR RED (240V)
BLACK
GROUND
(GREEN)
JUNCTION BOX
WITH COVER
12 AWG ROMEX
OR SUITABLE
JUNCTION BOX
TERMINAL
STRIP