WarmlyYours TempZone™ Custom & Standard Mat Product information

  • I have reviewed the provided wiring diagram for WarmlyYours Custom and Standard Mats TH115-AF-GA, TH114-AF-GA with SmartStat™ or EasyStat™ thermostats. The document details the electrical connections and grounding required for proper installation. I'm ready to address any questions you might have about connecting the mat, the thermostat, or the floor sensor.
  • Does the mat have polarity?
    Can I shorten or cut the mat?
    What should I ensure during installation?
WIRING DIAGRAM
FOR WARMLYYOURS CUSTOM & STANDARD MATS
WITH THE SMARTSTAT™ / EASYSTAT™
ITEM #: TH115-AF-GA ITEM #: TH114-AF-GA
ELECTRICAL ROUGH-IN
MOUNTING HARDWARE
4” x 4” DEEP TWO GANG
SQUARE BOX SUPPLIED
BY CONTRACTOR
SINGLE GANG MUD RING (PLASTER
RING) SUPPLIED BY CONTRACTOR
SMARTSTAT™
EASYSTAT™
HOT
THERMOSTAT SENSOR WIRE
(LOW VOLTAGE)
FROM POWER SOURCE 120V & 240V
PB112C-GA
FRONT BASE
4000461
12
1. ENSURE THE SYSTEM IS GROUNDED
2. MAT HAS NO POLARITY
3. DO NOT SHORTEN OR CUT MAT
HOT (240V) or
NEUTRAL (120V)
6/17/99
- 1/2" CONDUIT IF ONLY
ONE ROLL IS USED
- 3/4" CONDUIT IF 2 OR 3
ROLLS ARE USED
1/2" CONDUIT
FOR FLOOR
SENSOR
CONDUIT TO
POWER SOURCE
WARMING SYSTEM
4" x 4" DEEP TWO GANG
SQUARE BOX WITH SINGLE
GANG MUD RING FOR
CONNECTION TO THERMOSTAT
Free Design Service • 24/7 Installation Support • No Nonsense™ Warranty •(800) 875-5285 • www.WarmlyYours.com
30046-G 6/12
HOUSE GROUND
VOLTAGE INDICATORS
RED (240V) OR
WHITE (120V)
RED
BLACK
Red
Black
BRAIDED
GROUND
SHEATH
THERMOSTAT
Load
S
L2 (N)
L1 (L)
SENSOR PROBE
BLACK
BRAIDED GROUND SHEATH
COLD LEAD
RED 240V
OR
WHITE 120V
BLACK
RETURN
WIRE
/