FC LIGHTING FCB459 Installation guide

Type
Installation guide
t 800.900.1730 f 630.889.8106
3609 Swenson Ave. St. Charles, IL 60174
Rev. 715
FCB459 (Concrete Pour) - INSTALLATION INSTRUCTIONS
CAUTION: BEFORE CONNECTING THE FIXTURE TO A POWER SUPPLY, MAKE SURE THE POWER IS SWITCHED OFF.
DETAILED ILLUSTRATION
THIS DOCUMENT IS PROPRIETARY TO FC LIGHTING, INC. ANY UNAUTHORIZED TRANSFER, USE OR REPRODUCTION IS STRICTLY PROHIBITED. IMPROPER INSTALLATION OR MAINTENANCE OF FIXTURES WILL VOID WARRANTY. ©2018 FC LIGHTING, INC.
GENERAL:
1. Before starting the installation, make sure all electricity has been turned
off and electrical breaker has been locked out and tagged out.
2. To ensure the success of the installation, be sure to read these
instructions and review the diagrams thoroughly before beginning.
3. All electrical connections must be in accordance with local codes,
ordinances, or the National Electrical Code.
NOTE: The important safeguards and instructions appearing in this manual
are not meant to cover all possible conditions and situations that may occur.
1) FOOTING DESIGN:
All footings should be poured to direct water away from the base
of the xture. Drainage should be provided to prevent water from
collecting under and around the xture. Anchors must be located per
the dimensions shown (see next page). Anchor Bolts are galvanized
steel. The unthreaded portion should be in the concrete and the threaded
portion should be 7/8” above the concrete.
2) INSTALL MOUNTING RING:
Remove the top assembly from the bottom mounting plate by loosening
the (2) screws on top of the housing. DO NOT remove screws completely.
Once the footing is set and level, connect 1/2” (O.D.) conduit to the
bottom of mounting plate and pull wiring into the base housing. Using (4)
nuts and washers, anchor the mounting plate to the nished concrete.
TIGHTEN EVENLY AND DO NOT OVERTIGHTEN.
3) WIRING:
Make wiring connections. All wiring connections must be made in
accordance with local electrical codes, ordinances, and the National
Electric Code (NEC).
4) Place bollard top assembly over base mounting plate. Tighten the (2) top
screws evenly until xture is held rmly in place. Tighten screws evenly
to create a proper seal.
5) Place a bead of silicone caulk around the bottom edge of the bollard
where the xture meets the concrete.
IMpORTANT: All FC
|
SSL products can be cleaned with non-abrasive and chemical
free agents. Use a soft cloth with mild detergent on exterior only.
















 





































See template on next page for Anchor Bolt locations.
9.4 in
9.6 in
9.4 in
Concrete Minimum Depth
(Bolts are 12” Long)
(Bolt tops should be
7/8” above cement)
Bolts are 7/8”
above cement.
Allow conduit 1”
above cement,
trim as needed to
connect to base.
12” (102 mm)
Concrete Minimum Depth
(Bolts are 12” Long)
(Bolt tops should be
7/8” above cement)
Bolts are 7/8”
above cement.
Allow conduit 1”
above cement,
trim as needed to
connect to base.
12” (102 mm)
Top
Assembly
Bottom
Mounting
Plate
t 800.900.1730 f 630.889.8106
3609 Swenson Ave. St. Charles, IL 60174
Rev. 715
FCB459 - J-BOLT SPACING DIMENSIONS TEMPLATE
REFER TO MEASUREMENTS FOR ACTUAL SIZE. DRAWING SHOWS ACTUAL BOTTOM OF FIXTURE.






















































THIS DOCUMENT IS PROPRIETARY TO FC LIGHTING, INC. ANY UNAUTHORIZED TRANSFER, USE OR REPRODUCTION IS STRICTLY PROHIBITED. IMPROPER INSTALLATION OR MAINTENANCE OF FIXTURES WILL VOID WARRANTY. ©2018 FC LIGHTING, INC.
  • Page 1 1
  • Page 2 2

FC LIGHTING FCB459 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI