Juniper IDP 1100F Installer's Manual

Category
Networking
Type
Installer's Manual
Juniper Networks, Inc.
1194 North Mathilda Avenue
Sunnyvale, CA 94089
USA
408-745-2000
www.juniper.net
Part Number: 093-1721-000, Rev B
Intrusion Detection and Prevention
Installer’s Guide
IDP 50, 200, 600, 1100
Release 3.2, Rev. B
Copyright Notice
Copyright © 2005 Juniper Networks, Inc. All rights reserved.
Juniper Networks and the Juniper Networks logo are registered trademarks of Juniper Networks, Inc. in the United States and other countries. All other
trademarks, service marks, registered trademarks, or registered service marks in this document are the property of Juniper Networks or their respective
owners. All specifications are subject to change without notice. Juniper Networks assumes no responsibility for any inaccuracies in this document or for
any obligation to update information in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication
without notice.
FCC Statement
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. The equipment generates, uses, and can radiate radio-frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
The following information is for FCC compliance of Class B devices: The equipment described in this manual generates and may radiate radio-frequency
energy. If it is not installed in accordance with NetScreen’s installation instructions, it may cause interference with radio and television reception. This
equipment has been tested and found to comply with the limits for a Class B digital device in accordance with the specifications in part 15 of the FCC
rules. These specifications are designed to provide reasonable protection against such interference in a residential installation. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Consult the dealer or an experienced radio/TV technician for help.
Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
Caution: Changes or modifications to this product could void the user's warranty and authority to operate this device.
Disclaimer
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED
WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED
WARRANTY, CONTACT YOUR JUNIPER NETWORKS REPRESENTATIVE FOR A COPY.
Writer: Mark Schlagenhauf
Editor:
Table of Contents iii
Table of Contents
About This Guide xi
Audience.........................................................................................................xi
Conventions....................................................................................................xi
Documentation..............................................................................................xii
Release Notes..........................................................................................xii
Online Help.............................................................................................xii
Web Access............................................................................................xiii
Comments About the Documentation...........................................................xiii
Contacting Customer Support .......................................................................xiii
Chapter 1 Hardware Overview 1
IDP Sensors......................................................................................................1
IDP 50 Sensor............................................................................................1
IDP 200 Sensor..........................................................................................1
IDP 600C Sensor .......................................................................................2
IDP 600F Sensor........................................................................................2
IDP 1100C Sensor .....................................................................................3
IDP 1100F Sensor......................................................................................3
Sensor Components.........................................................................................3
Traffic Ports (Forwarding Interfaces) .........................................................4
NIC Bypass Mode (Internal Bypass).....................................................4
NIC Bypass and Cable Choices............................................................4
Peer Port Modulation (PPM)................................................................5
Management Interfaces.............................................................................5
Hard Drives and CD-ROM Drives...............................................................6
Power Supplies..........................................................................................6
LED Definitions................................................................................................6
System Status LEDs...................................................................................6
Management and High Availability Port LEDs............................................8
Traffic Port LEDs .......................................................................................9
Copper Traffic Port LEDs.....................................................................9
Fiber Traffic Port LEDs (IDP 600F and 1100F only)...........................10
Hard Drive, CD-ROM Drive, and Power Supply LEDs (Back Panel) ..........10
Chapter 2 Planning an Installation 11
IDP Configuration Basics................................................................................11
IDP System Components.........................................................................11
Steps for installing and configuring an IDP system..................................11
IDP Sensor Placement....................................................................................12
IDP Sensor Deployment Mode .......................................................................12
IDP Individual Deployment Modes ..........................................................12
Sniffer Mode (Passive Mode).............................................................13
Transparent Mode (Inline Active Mode).............................................14
iv Table of Contents
IDP 50, 200, 600, 1100 Installer’s Guide
Chapter 3 Installing the Sensor 15
General Installation Guidelines.......................................................................15
Rack Mounting the IDP Sensor.......................................................................16
Connecting Power..........................................................................................18
Connecting Management Ports ......................................................................19
Use the Serial Console Port to Change the MGT Port IP Address..............19
Ethernet Management Port......................................................................20
Chapter 4 Configuring the IDP Sensor 23
Before You Begin ...........................................................................................23
Connecting to the IDP Sensor ........................................................................25
Connecting Directly.................................................................................25
Connecting Remotely ..............................................................................25
Configuring the IDP Sensor with ACM............................................................26
Connecting the IDP Sensor to Your Network..................................................26
Connecting the Management Port ...........................................................26
Connecting Forwarding Interfaces...........................................................26
Connecting the High Availability Port ......................................................26
Chapter 5 Installing the IDP Management Server Software 27
Pre-Installation Requirements........................................................................27
Hardware Requirements..........................................................................27
Red Hat Linux Server........................................................................27
Sun Solaris Server .............................................................................27
Software Requirements...........................................................................28
Operating System .............................................................................28
Partition Information..................................................................28
Other Software Requirements...........................................................28
Red Hat RPMs ............................................................................28
Sun Solaris Packages ..................................................................29
Installing the Management Server..................................................................29
Chapter 6 Installing and Running the User Interface 31
Installing the UI..............................................................................................31
Installing on a Windows Host..................................................................31
Installing on a Red Hat Linux Host...........................................................31
Running the UI...............................................................................................32
Windows.................................................................................................32
Linux.......................................................................................................32
Chapter 7 Updating Software on the Sensor 33
Updating IDP Sensor Software.......................................................................33
Re-Imaging the IDP Sensor ............................................................................34
Chapter 8 Servicing the Device 35
Removing and Installing a Power Supply (IDP 200, 600, and 1100 Only)......35
To Remove a Power Supply or Blank.......................................................35
To Install a Power Supply ........................................................................37
Removing and Installing a SCSI Hard Drive (IDP 600 and 1100 Only) ...........38
To Remove a SCSI Hard Drive.................................................................38
To Install a SCSI Hard Drive.....................................................................41
Table of Contents
Table of Contents
v
Connecting and Disconnecting Fiber Cables (IDP 600F and 1100F Only) ......42
Chapter 9 Advanced Configuration 45
Advanced Deployment Modes .......................................................................45
Router Mode .....................................................................................47
IDP High Availability (HA) Deployment Modes...............................................48
Appendix A Specifications 49
IDP 50 Technical Specifications .....................................................................49
IDP 200 Technical Specifications ...................................................................50
IDP 600 Technical Specifications ...................................................................51
IDP 1100 Technical Specifications .................................................................51
Safety Compliance.........................................................................................52
EMI Compliance.............................................................................................52
Immunity.......................................................................................................53
Index.......................................................................................................................... 55
vi Table of Contents
IDP 50, 200, 600, 1100 Installer’s Guide
List of Figures vii
List of Figures
Figure 1: IDP 50 Front Panel ..........................................................................1
Figure 2: IDP 200 Front Panel ........................................................................2
Figure 3: IDP 600C Front Panel......................................................................2
Figure 4: IDP 600F Front Panel ......................................................................2
Figure 5: IDP 1100C Front Panel....................................................................3
Figure 6: IDP 1100F Front Panel ....................................................................3
Figure 7: Copper and Fiber Ports....................................................................4
Figure 8: IDP 50 System Status LEDs..............................................................7
Figure 9: IDP 200, 600, 1100 System Status LEDs..........................................7
Figure 10:MGT and HA ports with LEDs...........................................................8
Figure 11:Copper and Fiber Ports with LEDs...................................................9
Figure 12:Rail with Hinged Rear Bracket .......................................................17
Figure 13:2U Device Mid-Mount Bracket........................................................18
Figure 14:1U Device (IDP 50) Mid-Mount Bracket..........................................18
Figure 15:Power Supply Handles in Open and Closed Positions ....................36
Figure 16:Power Supply Partially Removed...................................................37
Figure 17:Hard Drive Latch in Closed Position...............................................39
Figure 18:Hard Drive Latch in Open Position, Handle Released.....................39
Figure 19:Hard Drive Handle Down...............................................................40
Figure 20:Drive Partially Removed................................................................40
Figure 21:Drive Partially Inserted ..................................................................41
Figure 22:Hard Drive Latch in Closed Position...............................................42
viii List of Figures
IDP 50, 200, 600, 1100 Installer’s Guide
List of Tables ix
List of Tables
Table 1: Notice Icons....................................................................................xi
Table 2: Font Conventions Used in Code Examples......................................xi
Table 3: IDP Sensor Drives............................................................................6
Table 4: IDP Sensor Power Supplies..............................................................6
Table 5: IDP Sensor System Status LED Definitions.......................................7
Table 6: IDP Sensor Management and High Availability Port LED Definitions8
Table 7: Copper Traffic Port LED Definitions.................................................9
Table 8: Fiber Traffic Port LED Definitions ..................................................10
Table 9: Hard Drive, CD-ROM Drive, and Power Supply LED Definitions ....10
Table 10: Information Needed for ACM Configuration...................................23
Table 11: Physical Specifications...................................................................49
Table 12: AC Power Specifications ................................................................49
Table 13: Power Cord Specifications .............................................................49
Table 14: Environmental Specifications.........................................................50
Table 15: Physical Specifications...................................................................50
Table 16: AC Power Specifications ................................................................50
Table 17: Power Cord Specifications .............................................................50
Table 18: Environmental Specifications.........................................................50
Table 19: Physical Specifications...................................................................51
Table 20: AC Power Specifications ................................................................51
Table 21: Power Cord Specifications .............................................................51
Table 22: Environmental Specifications.........................................................51
Table 23: Physical Specifications...................................................................51
Table 24: AC Power Specifications ................................................................52
Table 25: Power Cord Specifications .............................................................52
Table 26: Environmental Specifications.........................................................52
x List of Tables
IDP 50, 200, 600, 1100 Installer’s Guide
Audience xi
About This Guide
This Installer’s Guide describes the physical features of Juniper Networks Intrusion
Detection and Prevention (IDP) Solution: the IDP 50, IDP 200, IDP 600C, IDP 600F,
IDP 1100C, and 1100F Sensors. It also explains how to install and configure the IDP
system.
Audience
This guide is intended for experienced system and network specialists.
Conventions
Table 1 defines notice icons used in this guide, and Table 2 defines text conventions
used throughout the book.
The term “Sensor” is used to denote an IDP 50, 200, 600, or 1100 appliance.
Table 2: Font Conventions Used in Code Examples
Table 1: Notice Icons
Icon Meaning Description
NOTE: Informational note Indicates important features or instructions.
Caution Indicates that you may risk losing data or
damaging your hardware.
Warning Alerts you to the risk of personal injury.
Font Meaning
Regular
System output
Italic
Variables or placeholders in system output
Bold
User input
Bold italic Variables or placeholders in user input
IDP 50, 200, 600, 1100 Installer’s Guide
xii Documentation
Documentation
The Installer’s Guide is shipped in the box with all new IDP Sensors. This guide
provides the basic procedures for getting your IDP system up and running.
With each major software release, Juniper Networks provides the IDP
Documentation CD. The documentation CD contains the document set in PDF
format. The documentation is also available on the Web at
http://www.juniper.net/techpubs/software/management/idp/.
The IDP document set comprises the following books:
Intrusion Detection and Prevention Concepts & Examples Guide – Explains basic
concepts of the IDP system and provides examples of how to use the system.
IDP 50, 200, 600, 1100 Installer’s Guide (this manual) – Describes the hardware
components of the IDP 50, 200, 600, and 1100 Sensors. Provides instructions
for rack-mounting, cabling, basic configuration, management server
installation, and user interface installation.
NetScreen Safety Guide - Contains safety warnings and instructions for installing
and using network devices.
Hardware Guide (650) – Contains important safety and compliance information
about the NetScreen-IDP 10 (650) Sensor.
Hardware Guide (1650) – Contains important safety and compliance information
about the NetScreen-IDP 100 and 500 (1650) Sensors.
Hardware Guide (1750) – Contains important safety and compliance information
about the NetScreen-IDP 10, 100, 500, and 1000 (1750) Sensors.
QuickStart Guide, IDP 3.2 - QuickStart instructions for the NetScreen-IDP 10,
100, 500, and 1000.
QuickStart Guide, IDP 3.2, High Availability - QuickStart instructions for the
NetScreen-IDP 10, 100, 500, and 1000 set up in High Availability (HA) mode.
Release Notes
Release notes are available on the Web at
http://www.juniper.net/techpubs/software/management/idp/.
In the Release Notes, you will find the latest information about features, changes,
known problems and resolved problems. If the information in the Release Notes
differs from the information found in the documentation set, follow the Release
Notes.
Online Help
The IDP Appliance Configuration Manager (ACM) contains online help. The online
help provides explanations for sensor configuration options.
Comments About the Documentation xiii
About This Guide
The IDP User Interface (UI) contains online help. The online help provides
instructions for using the UI as well as step-by-step directions for performing
common tasks.
Web Access
To view the documentation on the Web, go to:
http://www.juniper.net/techpubs/software/management/idp/
Comments About the Documentation
We encourage you to provide feedback, comments, and suggestions so that we can
improve the documentation to better meet your needs. Please e-mail your
comments to:
techpubs-comments@juniper.net
Along with your comments, be sure to indicate:
Document name
Document part number (located under the Juniper Networks address on the
title page)
Page number
Hardware platform and/or software release version
Contacting Customer Support
For technical support, contact Juniper Networks at support@juniper.net, or at
1-888-314-JTAC (within the United States) or +1-408-745-9500 (from outside the
United States).
IDP 50, 200, 600, 1100 Installer’s Guide
xiv Contacting Customer Support
IDP Sensors 1
Chapter 1
Hardware Overview
This chapter provides detailed descriptions of the Juniper Networks IDP Sensors
and their components.
IDP Sensors
Sensor Components on page 3
LED Definitions on page 6
IDP Sensors
IDP 50 Sensor
The IDP 50 Sensor is optimal for small networks or low-speed network segments. It
features:
2 copper Ethernet ports (10/100/1000 Mbps)
1 Dedicated Management port
1 Serial Console port
Figure 1: IDP 50 Front Panel
IDP 200 Sensor
The IDP 200 Sensor is optimal for medium central sites or large branch offices. It
features:
8 copper Ethernet ports (10/100/1000 Mbps)
1 Dedicated Management port
1 Dedicated High Availability port
1 Serial Console port
IDP 50, 200, 600, 1100 Installer’s Guide
2 IDP Sensors
Figure 2: IDP 200 Front Panel
IDP 600C Sensor
The IDP 600C Sensor is optimal for medium-to-large central sites or high-traffic
areas. It features:
10 copper Ethernet ports (10/100/1000 Mbps)
1 Dedicated Management port
1 Dedicated High Availability port
1 Serial Console port
Figure 3: IDP 600C Front Panel
IDP 600F Sensor
The IDP 600F Sensor is optimal for medium-to-large central sites or high-traffic
areas. It features:
8 fiber Ethernet ports (sx Gigabit)
2 copper Ethernet ports (10/100/1000 Mbps)
1 Dedicated Management port
1 Dedicated High Availability port
1 Serial Console port
Figure 4: IDP 600F Front Panel
Sensor Components 3
Chapter 1: Hardware Overview
IDP 1100C Sensor
The IDP 1100C Sensor is optimal for large central sites or high-traffic areas. It
features:
10 copper Ethernet ports (10/100/1000 Mbps)
1 Dedicated Management port
1 Dedicated High Availability port
1 Serial Console port
Figure 5: IDP 1100C Front Panel
IDP 1100F Sensor
The IDP 1100F Sensor is optimal for large central sites or high-traffic areas. It
features:
8 fiber Ethernet ports (sx Gigabit)
2 copper Ethernet ports (10/100/1000 Mbps)
1 Dedicated Management port
1 Dedicated High Availability port
1 Serial Console port
Figure 6: IDP 1100F Front Panel
Sensor Components
This section describes the components and indicator LEDs of the IDP 50, 200, 600,
and 1100 Sensors.
IDP 50, 200, 600, 1100 Installer’s Guide
4 Sensor Components
Traffic Ports (Forwarding Interfaces)
The IDP 50, 200, 600, and 1100 have traffic ports (forwarding interfaces) located on
the right side of each device. Some devices have copper ports only, while others
have a mixture of copper and fiber.
Figure 7: Copper and Fiber Ports
NIC Bypass Mode (Internal Bypass)
Copper ports on the IDP 50, 200, 600, and 1100 all have built-in port bypass. Port
bypass only works if the sensor is configured for transparent mode. If a Sensor fails
while in transparent mode, the pair of ports will automatically fail into a
connected” state, and traffic will flow through them to and from the rest of the
network, without being analyzed.
NIC Bypass works using a watchdog timer. Each pair of ports has a timer. The
Sensor sends each timer a reset signal every second. If a timer does not receive a
reset signal for three seconds, bypass activates. After bypass activates, the timer
continues listening for a reset signal. When the timer receives a reset signal, bypass
deactivates automatically and the Sensor goes back to normal operation.
Bypass mode only activates if the Sensor fails (power loss, system crash). If the
Sensor (or Sensor software) is shut down gracefully, Internal Bypass is
deactivated and traffic does not flow through the device. Use of service idp
stop, shutdown -r now, or shutdown -h stop in the CLI all produce a graceful
shutdown and deactivates Internal Bypass.
The fiber Gigabit ports are standard interfaces and do not incorporate the
integrated bypass feature. Automatic bypass is available for fiber ports via
third-party devices.
NIC Bypass and Cable Choices
When NIC Bypass activates, it physically connects the pair of forwarding interfaces
to each other, with a crossover. From the network’s point of view, the two cables
connected to the Sensor have become one, long crossover cable.
If you are connecting devices that support auto-MDIX, then you can use whatever
cables you want, because auto-MDIX will negotiate the correct connection.
However, if neither of the devices support auto-MDIX, then you need to take special
care to choose the right cables.
Sensor Components 5
Chapter 1: Hardware Overview
Imagine the two devices, one connected to one Sensor port and the other
connected to the other Sensor port, are instead connected directly together. Would
you use a straight-through cable or a cross-over cable?
If the two devices would be connected with a straight-through cable, then use one
straight-through cable and one cross-over cable to connect the Sensor to these
devices. When NIC Bypass kicks in, this will have the result of creating one, long
straight-through cable connecting the devices.
If the two devices would be connected with a cross-over cable, then use two
straight-through cables to connect the Sensor to these two devices. When NIC
Bypass kicks in, this will have the result of creating one, long cross-over cable
connecting the devices.
Peer Port Modulation (PPM)
When Peer Port Modulation is enabled, if any of the interfaces in a virtual router
become unavailable, the Sensor deactivates all the interfaces in that virtual router.
All devices connected to the virtual router will detect a port failure and must be
configured to take appropriate action.
You cannot enable NIC Bypass and Peer Port Modulation on the same Sensor.
PPM works somewhat differently on the IDP 50, 200, 600, and 1100 than it did on
the IDP 10, 100, 500, and 1000.
On the older IDP Sensors (10, 100, 500, 1000):
PPM does not work on fiber interfaces
PPM works by changing the interface speed/duplex settings to 10
mbps/half-duplex, not by turning off the interfaces. Because of this, interface
speeds have to be hardcoded (could not be auto) on both the Sensor and on the
attached switches.
On the newer IDP Sensors (50, 200, 600, 1100):
PPM works on both copper and fiber interfaces
PPM works by turning off appropriate interfaces. Because of this, interface
speeds can be set to auto on the Sensor and on attached switches.
Management Interfaces
These interfaces are provided on all IDP Sensors.
Serial Console (CONSOLE)
The Console port provides access, via a DB-9 serial port, to the Sensor’s command
line interface (CLI).
IDP 50, 200, 600, 1100 Installer’s Guide
6 LED Definitions
Management Port (MGT)
The Management port provides access, via 10/100/1000 Mbps Ethernet, to the
Sensor. The Appliance Configuration Manager (ACM) is accessed via the
Management Port (https://<Sensor_IP_Address>.
Hard Drives and CD-ROM Drives
Table 3: IDP Sensor Drives
Power Supplies
Table 4: IDP Sensor Power Supplies
LED Definitions
This section describes the LEDs for the following IDP Sensor components:
System status
Management and High Availability port
Traffic port
Disk drive, CD-ROM drive, and power supply (back panel)
System Status LEDs
The IDP 50 Sensor has three system status lights on the front panel: PWR, HD, and
OVERHEAT.
IDP Sensor Hard Drives and CD-ROM Drives
50 1 CD-ROM drive
1 internal hard drive
200 1 CD-ROM drive
1 internal hard drive
600 and 1100 1 CD-ROM drive
2 externally accessible hot-swappable SCSI RAID
1 mirrored hard drives
IDP Sensor Power Supplies
50 1 fixed power supply
200 1 removable power supply
Empty bay for second, optional power supply
600 and 1100 2 removable hot-swappable power supplies
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70

Juniper IDP 1100F Installer's Manual

Category
Networking
Type
Installer's Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI