IFM NF5030 Operating instructions

Type
Operating instructions
Operating instructions
(Ex protection related part)
Inductive NAMUR sensor
NE / NF /
NG / NI /
NN / NT /
NS
11455630 / 0008 / 2022
GB
NE / NF / NG / NI / NN / NT / NS Inductive NAMUR sensor
2
1 Safety instructions
Remarks for safe use in hazardous areas.
The device must only be installed, connected and set up by qualified staff. The qualified staff must
have knowledge of types of protection, regulations and provisions for apparatus in hazardous
areas.
The classification and marking of the device must be suitable for the application.
Adhere to the respective national regulations and provisions as well as the relevant installation
regulations.
Observe applicable documents.
2 Intended use
Use in hazardous areas according to the classification:
NT / NE / NF:
ATEX classification Marking Permissible ambient temperature
II 1G Ex ia IIC T6 Ga Ta -20...70°C
II 1D Ex ia IIIC T₂₀₀ 90°C Da Ta -20...70°C
ATEX classification Marking Permissible ambient temperature
II 1G Ex ia IIC T5 Ga Ta -20...80°C
II 1D Ex ia IIIC T₂₀₀ 100°C Da Ta -20...80°C
NG / NI / NN / NS:
ATEX classification Identification Permissible ambient temperature
II 1G Ex ia IIB T6 Ga Ta -20...70°C
II 2G Ex ia IIC T6 Gb Ta -20...70°C
II 1D Ex ia IIIC T₂₀₀ 90°C Da Ta -20...70°C
ATEX classification Marking Permissible ambient temperature
II 1G Ex ia IIB T5 Ga Ta -20...80°C
II 2G Ex ia IIC T5 Gb Ta -20...80°C
II 1D Ex ia IIIC T₂₀₀ 100°C Da Ta -20...80°C
Type examination certificate:
EU: PTB 01 ATEX 2191, BVS 04 ATEX E153 X
IEC: IECEx BVS 06.0003X
The requirements of the following standards are met:
EN IEC 60079-0:2018, EN 60079-11:2012
IEC 60079-0:2017, IEC 60079-11:2011
Connection only to intrinsically safe circuits which are approved with the type examination certificate
and do not exceed the following maximum values:
Inductive NAMUR sensor NE / NF / NG / NI / NN / NT / NS
3
Ui = 15 V, Ii = 50 mA, Pi = 120 mW
Maximum effective internal inductance (Li) and capacitance (Ci):
Article number Internal inductance (Li) in µH Internal capacitance (Ci) in nF
NE5001 70 80
NE5012 87 83
NF5001, NF5002 340 140
NF5003, NF5004 130 140
NF5008, NF5010 134 141
NF5012 344 141
NF5023 147 143
NF5030 134 141
NG5001, NG5002 45 145
NG5003, NG5004 50 155
NG5010 58 157
NG5011 53 147
NG5016 62 157
NG5019 49 146
NG5021 54 156
NI5001, NI5002 140 145
NI5003, NI5004 110 145
NI5011 118 147
NI5012 148 147
NN5001, NN5002 135 110
NN5020 143 112
NS5002 110 80
NT5001 70 80
NT5005 74 81
3 Installation
uProtect device and cable against destruction.
uAvoid electrostatic charging on plastic housings and cables.
uTo avoid electrostatic charging, ensure the equalisation of potential of metal parts (connector
housing, fixing elements, protective housing, etc.).
uDo not install the device in the partition between different zones.
uWhen used in zone 0, protect the sockets against intensive electrostatic charging.
3.1 Special conditions for safe operation
uAlways refer to the operating instructions for the identification, as it may not be fully applied to the
device due to lack of space.
NE / NF / NG / NI / NN / NT / NS Inductive NAMUR sensor
4
4 Maintenance, repair and disposal
The device must not be modified nor can it be repaired. In case of a fault please contact the
manufacturer.
If needed, data sheets and type examination certificates or other certificates can be requested from