FIG-2-A FIG-2-B
FIG-4
FIG-3 FIG-5
1
OFF
ON 2
1
OFF
ON 2
ver:1.2
FIG-6
Wrench,Gasket
FIG-1
Freely choose tool
to fix the backstand.
Concrete Wood board
Please make sure the
thickness of the wood
board no less than 5mm
Gasket
EX161
1
2
23
29MM
56MM
31MM
1
12
green/yellow
brown
blue
N L
N
L
0.5-2.5mm² with
release facility
2
1
UP
Please install the side
marked with “up” label
in the top for backstand.
Note: In order to reach the required IP,
the input cable for the luminaries must
be H05RN-F 3×1.0mm², and threading
through before stripping.
Note: Please keep
the cable outlet in
the same vertical
direction with the
inlet to luminaries
2
1
Pri:220-240V
for cable/pipe mm: ∅5-10
H05RN-F 3×1.0mm²
If the external flexible cable or cord of this luminaire is damaged, it shall
be exclusively replaced by the manufacturer or his service agent or a
similar qualified person in order to avoid a hazard.
The light source of this luminaire is not replaceable;
when the light source reaches its end of life the whole luminaire shall
be replaced.
This luminaire must be installed by a qualified Registered Electrician to
prevent damage to the luminaire and maintain electrical safety.
Base plate,cable entry gland and screw heads must be covered in silicone
sealant. Failure to do so may cause luminaire failure from water ingress.
All exterior luminaires (with the exception of copper) require periodic
cleaning to protect the surface and/or coating from corrosion and ensure
tidy appearance for the lifespan of the product. Wash with care using a
soft brush and warm soapy water using a neutral detergent. Coastal
areas require extra attention, especially fittings which are under
eaves/soffits and do not have any exposure to rain. Do not use a water
blaster or high pressure hose, do not submerge fittings for extended
periods of time. 316 stainless steel fittings will still develop surface
rust or “tea staining” if left uncared for.