Rev. 00 COMPRESSION FITTING INSTALLATION INSTRUCTIONS
Compression Fitting
Installation
Read Instructions Carefully Prior to Install.
1. Shut off water supply.
2. Check tubing for dents, bends, putty or
burrs and make sure it is cut square.
Fix/cut accordingly.
3. Place new compression nut on the pipe (threads
facing valve), then the ferrule sleeve.
4. Slide valve on to the pipe until it bottoms out such
that the tube is seated all the way into the fitting. DO
NOT USE SEALANT/PUTTY/PIPE
DOPE/TAPE. Usage of these materials will result
in a leak or valve failure.
5. Slide the sleeve back until it is touching the valve,
then bring the nut over top of it. Again, ensure the
supply pipe remains seated and square to the fitting.
6. Hand tighten the nut onto the supply port making
sure it is threading on smoothly.
7. Stabilize the valve and tighten nut 1/2 of a turn. DO NOT OVERTIGHTEN.
Overtightening can lead to failure and leaking long after installation.
8. Attach tubing/hose to other end of the valve, turn on water supply and check for leaks. If
a leak occurs, turn the water off and tighten appropriate nut in quarter turn increments
until leak has subsided. Do not exceed 3/4 more turns or damage is possible. If leak
still remains, it is necessary to take back off compression nut and ferrule sleeve and
inspect the pipe for signs that could cause an improper seal (burrs, nicks, bends, etc.).
(See installation pictures on next page for assistance)
2
Rev. 00 COMPRESSION FITTING INSTALLATION INSTRUCTIONS
1
2
3
4
5
  • Page 1 1
  • Page 2 2

Jaclo 5812-PCH Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI