Dahua FAD201A User manual

Type
User manual

Dahua FAD201A is a 4-wire Non-addressable Smoke Detector. It is designed for fire pre-alarm in residential and industrial places such as malls, hotels, stores, warehouses, and electric machine rooms. FAD201A is characterized by high sensitivity, stability, reliability, low power consumption, attractive appearance, durability, and convenient use. When smoke is produced and reaches a certain concentration, the detector gives an alarm signal. Used with security and building systems, FAD201A effectively reduces fire casualty and property loss.

Dahua FAD201A is a 4-wire Non-addressable Smoke Detector. It is designed for fire pre-alarm in residential and industrial places such as malls, hotels, stores, warehouses, and electric machine rooms. FAD201A is characterized by high sensitivity, stability, reliability, low power consumption, attractive appearance, durability, and convenient use. When smoke is produced and reaches a certain concentration, the detector gives an alarm signal. Used with security and building systems, FAD201A effectively reduces fire casualty and property loss.

4-wire Non-addressable Smoke Detector
Users Manual
V1.0.0
ZHEJIANG DAHUA VISION TECHNOLOGY CO.,LTD.
I
Legal Statement
Trademark
,, and are the trademarks or registered
trademarks of the Dahua in various jurisdictions.
HDMI logo, HDMI and High-Definition Multimedia Interface are trademarks or registered
trademarks of HDMI Licensing LLC. This product has been authorized by HDMI Licensing
LLC to use HDMI technology.
VGA is the trademark of IBM.
Windows logo and Windows are trademarks or registered trademarks of Microsoft.
Other trademarks and company names mentioned are the properties of their respective
owners.
About this Document
This document is for reference only. Please refer to the actual product for more details.
This document serves as a reference for multiple types of products, whose specific
operations won’t be enumerated. Please operate according to actual products.
The user shall undertake any losses resulting from violation of guidance in the document.
In case that PDF document cannot be opened, please upgrade the reading tool to the
latest version or use other mainstream reading tools.
This company reserves rights to revise any information in the document anytime; and the
revised contents will be added to the new version without prior announcement. Some
functions of the products may be slightly different before and after revision.
The document may include technically inaccurate contents, inconsistencies with product
functions and operations, or misprint. Final explanations of the company shall prevail.
II
Cybersecurity Statement and Recommendations
Mandatory actions to be taken towards cybersecurity
1. Change Passwords and Use Strong Passwords:
The number one reason systems get “hacked” is due to having weak or default passwords. It is
recommended to change default passwords immediately and choose a strong password
whenever possible. A strong password should be made up of at least 8 characters and a
combination of special characters, numbers, and upper and lower case letters.
2. Update Firmware
As is standard procedure in the tech-industry, we recommend keeping NVR, DVR, and IP
camera firmware up-to-date to ensure the system is current with the latest security patches and
fixes.
“Nice to have” recommendations to improve your network security
1. Change Passwords Regularly
Regularly change the credentials to your devices to help ensure that only authorized users are
able to access the system.
2. Change Default HTTP and TCP Ports:
● Change default HTTP and TCP ports for systems. These are the two ports used to
communicate and to view video feeds remotely.
These ports can be changed to any set of numbers between 1025-65535. Avoiding the
default ports reduces the risk of outsiders being able to guess which ports you are using.
3. Enable HTTPS/SSL:
Set up an SSL Certificate to enable HTTPS. This will encrypt all communication between your
devices and recorder.
4. Enable IP Filter:
Enabling your IP filter will prevent everyone, except those with specified IP addresses, from
accessing the system.
5. Change ONVIF Password:
On older IP Camera firmware, the ONVIF password does not change when you change the
system’s credentials. You will need to either update the camera’s firmware to the latest revision
or manually change the ONVIF password.
6. Forward Only Ports You Need:
III
● Only forward the HTTP and TCP ports that you need to use. Do not forward a huge range of
numbers to the device. Do not DMZ the device's IP address.
You do not need to forward any ports for individual cameras if they are all connected to a
recorder on site; just the NVR is needed.
7. Disable Auto-Login on SmartPSS:
Those using SmartPSS to view their system and on a computer that is used by multiple people
should disable auto-login. This adds a layer of security to prevent users without the appropriate
credentials from accessing the system.
8. Use a Different Username and Password for SmartPSS:
In the event that your social media, bank, email, etc. account is compromised, you would not
want someone collecting those passwords and trying them out on your video surveillance
system. Using a different username and password for your security system will make it more
difficult for someone to guess their way into your system.
9. Limit Features of Guest Accounts:
If your system is set up for multiple users, ensure that each user only has rights to features and
functions they need to use to perform their job.
10. UPnP:
UPnP will automatically try to forward ports in your router or modem. Normally this would be a
good thing. However, if your system automatically forwards the ports and you leave the
credentials defaulted, you may end up with unwanted visitors.
If you manually forwarded the HTTP and TCP ports in your router/modem, this feature should
be turned off regardless. Disabling UPnP is recommended when the function is not used in real
applications.
11. SNMP:
Disable SNMP if you are not using it. If you are using SNMP, you should do so only temporarily,
for tracing and testing purposes only.
12. Multicast:
Multicast is used to share video streams between two recorders. Currently there are no known
issues involving Multicast, but if you are not using this feature, deactivation can enhance your
network security.
13. Check the Log:
If you suspect that someone has gained unauthorized access to your system, you can check
the system log. The system log will show you which IP addresses were used to login to your
system and what was accessed.
14. Physically Lock Down the Device:
IV
Ideally, you want to prevent any unauthorized physical access to your system. The best way to
achieve this is to install the recorder in a lockbox, locking server rack, or in a room that is
behind a lock and key.
15. Connect IP Cameras to the PoE Ports on the Back of an NVR:
Cameras connected to the PoE ports on the back of an NVR are isolated from the outside world
and cannot be accessed directly.
16. Isolate NVR and IP Camera Network
The network your NVR and IP camera resides on should not be the same network as your
public computer network. This will prevent any visitors or unwanted guests from getting access
to the same network the security system needs in order to function properly.
V
Preface
Overview
This product applies to fire pre-alarm in civil and industrial places, such as malls, hotels, stores,
warehouses and electric machine rooms. It is characterized by high sensitivity, stability, reliability, small
power consumption, attractive appearance, durability and convenient use. Used with security and
building systems, the detector gives an alarm signal when smoke is produced and reaches certain
concentration, and thus effectively reduces fire casualty and property loss.
Applicable models: DHI-FAD201A and FAD201A.
Symbol Definition
The following symbols may appear in the document. Please refer to the table below for the
respective definition.
Symbol
Note
It means highly potential danger. It will cause severe injury or
casualties if it fails to avoid.
It means moderate or low potential danger. It may cause slight or
moderate injury if it fails to avoid.
It means potential risk. It may cause device damage, data loss,
weaker performance or other unpredictable consequences if it fails
to avoid.
It means electrostatic-sensitive device.
It means high-voltage danger.
It means intensive laser radiation.
It means that it can help you to solve some problems or save your
time.
It means the additional information, which is the emphasis and
supplement of the main body.
VI
Important Safeguards and Warnings
The following description is the correct application method of the device. Please read the
manual carefully before use, in order to prevent danger and property loss. Strictly conform to
the manual during application and keep it properly after reading.
Please install this product according to the position in the user’s manual.
Please don’t place and install the device in an area exposed to direct sunlight or near heat
generating device.
Please don’t install the device in a humid, dusty or fuliginous area.
Please keep its horizontal installation, or install it at stable places, and prevent this product
from falling.
Please don’t drip or splash liquids onto the device; don’t put on the device anything filled
with liquids, in order to prevent liquids from flowing into the device.
Please install the device at well-ventilated places; don’t block its ventilation opening.
Use the device only within rated input and output range.
Please don’t install the device near magnetic fields.
Please don’t dismantle the device arbitrarily.
Please transport, use and store the device within allowed humidity and temperature range.
Please make sure to connect power cables according to requirements; otherwise, it may
result in fire or burning risks!
Wiring shall be installed and dismantled by electricians.
VII
System Operating Notice
Operating Notice about 4-wire non-addressable smoke detector
Although this product boasts stable and reliable performance, it may break down due to the
following reasons. Please read through the notice earnestly:
Fire zone isn’t protected, or smoke detector in fire zone breaks down.
This product is installed improperly or detection area is too large, so it fails to detect smoke
timely.
Abnormal power supply of the host leads to abnormal operation of the detector.
It breaks down in case of lack in regular maintenance and inspection of alarm system.
The alarm fails to detect smoke because smoke sensing component is covered by foreign
matters.
Notice to Installation Personnel
It is suggested that installation or maintenance personnel should inspect and maintain the
system regularly, at least once every month, in order to ensure that the system works
stably for a long time.
Installation or maintenance personnel shall train users, so users get to know the system
and operate the system proficiently.
System Test Notice
After installation, press test key on the product to carry out test.
VIII
Table of Contents
Legal Statement ......................................................................................................................................... I
Cybersecurity Statement and Recommendations ................................................................................ II
Preface ....................................................................................................................................................... V
Important Safeguards and Warnings .................................................................................................... VI
System Operating Notice ...................................................................................................................... VII
1 Product Overview .................................................................................................................................. 1
1.1 Product Profile ............................................................................................................................... 1
1.2 Product Appearance ..................................................................................................................... 1
1.3 Technical Index ............................................................................................................................. 2
2 Installation Instruction .......................................................................................................................... 3
2.1 Packing List ................................................................................................................................... 3
2.2 Installation Position ....................................................................................................................... 3
2.3 Product Installation ....................................................................................................................... 4
2.4 Wiring Mode .................................................................................................................................. 7
3 Device Test ............................................................................................................................................. 9
3.1 Device Test .................................................................................................................................... 9
3.2 Status Instruction .......................................................................................................................... 9
3.3 Maintenance and Cleaning ........................................................................................................... 9
4 Trouble and Repair ........................................................................................................................... 10
4.1 Troubleshooting........................................................................................................................... 10
4.2 Repair .......................................................................................................................................... 10
1
1 Product Overview
1.1 Product Profile
As a photoelectric detector, 4-wire non-addressable smoke detector detects certain quantity of smoke
when fire occurs, gives out an alarm, informs you to take actions at once, thus prevents fire from
expanding and reduces fire loss.
With MCU control, this detector makes an intelligent judgment of smoke concentration. In monitoring
status, red indicator flashes once every 9 seconds and working current is small. When on-site smoke
concentration exceeds preset alarm threshold value, the detector enters alarm status; red indicator
flashes continuously while the relay acts. With dry contact output of relay, alarm signals are sent to the
host, as relay contact acts differently. Moreover, dust accumulation auto-compensation function is able
to reduce the effect of dust on detector sensitivity.
1.2 Product Appearance
Its appearance and boundary dimension are shown in Figure 1-1.
Figure 1-1
2
1.3 Technical Index
Its technical parameters are shown in Table 1-1.
Parameter
Description
Working Principle
Photoelectric type
Relay Standby Status
Relay NO, 2A30VDC
Working Voltage
DC12V±3V
Working Current
Monitoring current ≤2mA, alarm current ≤25mA
Working Temperature
-10~+55
Working Humidity
Relative humidity≤95% (non-condensation)
Working Indication
Monitoring status: red indicator flashes once every 9 seconds;
Alarm status: red indicator flashes continuously.
Product Dimension
103mm×104m46mm
Product Weight
About 120g
Installation Mode
Ceiling installation
Table 1-1
3
2 Installation Instruction
2.1 Packing List
The following device and materials shall be included in the packing box. Please inspect them earnestly
according to Table 2-1 when opening the box and keep them properly.
Name
Quantity
4-wire Non-addressable Smoke Detector
1
User’s Manual
1
Screw Kit
1
Installation Sticker
1
Dust Cover
1
Table 2-1
2.2 Installation Position
Its installation shall conform to the following principles or local fire alarm design codes:
It shall be installed at least 300mm away from the corresponding wall, and 100mm away from wall
corner, as shown in Figure 2-1.
Figure 2-1
4
Multiple detection alarms shall be installed if the length is over 10m.
Don’t install it at the following positions:
High-humidity areas such as kitchen, water heater and bathroom;
Within 400mm away from air outlet of air conditioner, fan and central heating, as well as severe
convection area;
Dusty, dirty place or place with insects;
High-temperature and easily polluted place, such as cooker;
Place covered by things;
Within 300mm away from lamps;
The top of pinnacled room, room corner and other dead-air spaces;
When it is installed on tilted or pedestrian roof, the detection alarm shall keep certain distance from
the roof. The distance shall be 500mm when gradient is less than 30°, and shall be
500mm~1000mm when gradient is larger than 3, as shown in Figure 2-2.
Figure 2-2
2.3 Product Installation
Step 1 Get the detector from the package box.
Step 2 Rotate the baseplate counterclockwise and take it out, as shown in Figure 2-3.
5
Figure 2-3
Step 3 Take out installation stickers and affix them to proper installation positions of the
detector, as shown in Figure 2-4.
Figure 2-4
Step 4 Drill a 5mm-diameter hole in the center of two round holes of installation stickers
respectively, as shown in Figure 2-5.
Figure 2-5
Step 5 Put two plastic expansion screws from the screw kit to the round holes, as shown in
Figure 2-6. Hammer them into the holes, until their end faces are flush with the ceiling
or wall.
6
Figure 2-6
Step 6 Use a screwdriver to connect cables with corresponding metal sheets according to
marks, as shown in
Figure 2-7.
Figure 2-7
Step 7 Use two tapping screws in the kit to fix the installation baseplate, as shown in Figure
2-8.
Figure 2-8
Step 8 Align the long side of bottom cover of the detector with short side of the baseplate, put
it in, and then rotate the long side to long edge of the baseplate, as shown in Figure
2-9.
7
Figure 2-9
Step 9 Press the key on the obverse side of the detector, as shown in Figure 2-10. If LED
alarm light turns on, it means that the detection alarm works normally.
Figure 2-10
2.4 Wiring Mode
This is a normally open smoke detector, with normally open status output. When the system
connects multiple smoke detectors, they adopt parallel connection; power end and status
output end connect EOL (End of Line) to monitor. End monitoring is determined by the host.
Wiring diagram is shown in Figure 2-11.
8
Figure 2-11
9
3 Device Test
3.1 Device Test
To test the detector, when pressing the test key, red light flashes. If not, there is a failure. Please
refer to “Troubleshooting”.
Don’t test the alarm with open fire, which may damage the detection alarm or lead to fire
disaster!
It is recommended that standard smoke barrel should be used to test!
3.2 Status Instruction
Normal working status
In normal working status, indicator flashes once every 9 seconds.
Alarm status
When this device detects smoke and enters alarm status, indicator flashes continuously.
3.3 Maintenance and Cleaning
It is suggested that detection alarm should be tested once every month, and cleaned regularly to
remove dust.
A dust-absorption soft brush shall be used to clean the cover and every edge of detection alarm.
10
4 Trouble and Repair
4.1 Troubleshooting
Common troubles are shown in Table 4-1.
Trouble
Solution
The test key doesn’t respond
Take down detector, and inspect whether it is in good
contact.
Fire alarm is sent after it is power on.
There is much smoke dust or steam indoors. Please
power on again after smoke dust or steam
disappears.
Frequent false alarms
It may be caused by excessive dust in sensor maze.
Clear the maze (external black plastic part) with a
dust collector.
Table 4-1
4.2 Repair
In case that detection alarm cannot work normally within quality guarantee period, please contact the
seller; pay attention to packing protection and filling when returning the product. In case that detection
alarm is beyond quality guarantee period, please contact the manufacturer.
Don’t attempt to repair the detection alarm by yourself, which will affect the quality
guarantee!
Don’t attempt to remove the cover plate and clean the interior, which will affect the quality
guarantee!
ZHEJIANG DAHUA VISION TECHNOLOGY CO.,LTD.
AddressNo.1199, Bin'an Road, Binjiang District, Hangzhou, P.R. China
Postcode: 310053
Tel: +86-571-87688883
Fax: +86-571-87688815
Email:overseas@dahuatech.com
Website: www.dahuasecurity.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19

Dahua FAD201A User manual

Type
User manual

Dahua FAD201A is a 4-wire Non-addressable Smoke Detector. It is designed for fire pre-alarm in residential and industrial places such as malls, hotels, stores, warehouses, and electric machine rooms. FAD201A is characterized by high sensitivity, stability, reliability, low power consumption, attractive appearance, durability, and convenient use. When smoke is produced and reaches a certain concentration, the detector gives an alarm signal. Used with security and building systems, FAD201A effectively reduces fire casualty and property loss.

Ask a question and I''ll find the answer in the document