Kohler K-T10276-4-BN Installation guide

Category
Storage chests & cabinets & trunks
Type
Installation guide

This manual is also suitable for

Installation Guide
Single-Control Bath and Shower Trim
M product numbers are for Mexico (i.e. K-12345M)
Los números de productos seguidos de
M corresponden a México (Ej.
K-12345M)
Français, page“ Français-1”
Español, página“ Español-1”
K-T10274, K-T10275 K-T10276, K-T10277
K-T10280, K-T10281
1018257-2-B
IMPORTANT INSTRUCTIONS
READ AND SAVE FOR THE
CONSUMER
WARNING: Risk of scalding or other severe injury.
Before completing installation, the installer must set the
maximum water temperature setting of this valve to minimize the
risks associated with scalding hazards according to ASTM F 444.
Do not install a shut-off device on either outlet of this valve. The
installation of any such device may create a cross-flow condition
at the valve and affect the water temperature.
Factors that change the temperature of the water supplied to the
valve, such as seasonal water temperature changes, and water
heater replacement or servicing, will change the maximum water
temperature supplied by the valve and may create a scalding
hazard.
The pressure-balanced valve will not compensate for changes in
the water supply temperature; adjust the maximum water
temperature setting of this pressure-balanced valve when such
changes occur.
Pressure-balanced valves may not provide protection against
scalding if there is a failure of other temperature-limiting devices
elsewhere in the plumbing system.
The installer is responsible for installing the valve and adjusting the
maximum water temperature of this valve according to instructions.
This valve meets or exceeds ANSI A112.18.1 and ASSE 1016.
If you do not understand any of the installation or temperature
adjustment instructions in this document, in the United States please
contact our Customer Service Department at 1-800-4-KOHLER.
Outside the U.S., please contact your distributor.
IMPORTANT NOTICE TO INSTALLERS! Please fill in the blanks in
the information box in the Homeowners Guide and on the valve label.
Retain the Homeowners Guide for future reference.
1018257-2-B 2 Kohler Co.
Tools and Materials
Thank You For Choosing Kohler Company
We appreciate your commitment to Kohler quality. Please take a few
minutes to review this manual before you start installation. If you
encounter any installation or performance problems, please don’t
hesitate to contact us. Our phone numbers and website are listed on
the back cover. Thanks again for choosing Kohler Company.
Before You Begin
Observe all local plumbing and building codes.
The finished wall or bath/shower unit must be installed prior to
installing this trim.
We recommend that you determine if the maximum water
temperature is acceptable before installing this trim. If
temperature adjustment is needed, refer to the Water
Temperature Adjustment section.
The valve shuts off by water pressure. Do not force the handle in
any direction. To turn the valve off, gently turn it to the Off
position.
Shut off the main water supply.
If the wall thickness is greater than 3/4 (1.9 cm), use the Deep
Rough-in Kit (1025388) to add 3/4 (1.9 cm) of depth to the
handle assembly.
Kohler Co. reserves the right to make revisions in the design of
products without notice, as specified in the Price Book.
Assorted
Screwdrivers
Strap
Wrench
Plumbers
Putty
Thread
Sealant
Hex Wrench
Kohler Co. 3 1018257-2-B
1. Install the Spout
CAUTION: Risk of internal seal damage. Loosen the spout
setscrew with a 5/32 hex wrench prior to installing the spout.
CAUTION: Risk of internal seal damage. Do not use
petroleum-based lubricants. If the spout will not slide over the
tubing, use soapy water or silicone-based lubricant.
Threaded Spouts
Remove the temporary nipple from the bath elbow.
Apply thread sealant and install a 1/2 NPT nipple to extend
4-1/2 (11.4 cm) beyond the finished wall.
Apply a bead of plumbers putty or other sealant around the
spout base according to the manufacturer’s instructions. Leave a
small gap free of putty or other sealant at the bottom of the
spout.
Apply thread sealant to the nipple threads and install the spout
to the nipple.
Carefully tighten with a clean strap wrench.
Remove all excess putty.
Slip-Fit Spouts:
Remove the temporary nipple from the bath elbow.
Apply thread sealant and install a 1/2 copper tube to extend
from 2-1/8 (5.4 cm) to 3-1/2 (8.9 cm) beyond the finished wall.
Smooth the edges of the copper tubing.
Loosen the setscrew with a 5/32 hex wrench.
4-1/2"
(11.4 cm)
Threaded Spouts
Apply plumbers putty.
Nipple
2-1/8" (5.4 cm) to
3-1/2" (8.9 cm)
Slip-Fit
Spouts
Apply plumbers putty
5/32" Hex Wrench
Copper Tube
Setscrew
1018257-2-B 4 Kohler Co.
Install the Spout (cont.)
Apply a bead of plumbers putty or other sealant around the
spout base according to the manufacturer’s instructions. Leave a
small gap free of putty or other sealant at the bottom of the
spout.
Install the spout and carefully retighten the setscrew. Do not
overtighten.
Remove excess putty.
Kohler Co. 5 1018257-2-B
2. Install the Showerhead
CAUTION: Risk of product damage. To avoid clogging the
showerhead spray outlets, use thread sealant tape on the shower
arm threads. Do not use thread sealant (pipe dope).
Remove the temporary nipple from the shower elbow.
Apply a bead of plumbers putty or other sealant to the back of
the escutcheon according to the manufacturer’s instructions.
Slide the escutcheon over the shower arm.
Apply thread sealant tape and install the shower arm to the
shower elbow.
Carefully tighten with a clean strap wrench.
Press the escutcheon against the finished wall.
Remove all excess putty.
Flush out the system.
Apply thread sealant tape to the shower arm.
Install the screen washer.
Install the showerhead using a clean strap wrench.
Shower Elbow
Escutcheon
Shower Arm
Screen
Washer
Showerhead
1018257-2-B 6 Kohler Co.
3. Adjust the Water Temperature
CAUTION: Risk of personal injury. The water temperature
should never be set above 120° F (49° C).
NOTE: Do not remove the O-ring and collar at this time. Removing
the O-ring and collar will change the factory setting for the
maximum water temperature.
For minor water temperature changes:
Adjust the setscrew.
To check for significant water temperature changes, turn the valve
clockwise to the full open position and let the hot water run for
several minutes.
Position a thermometer in the water stream. The water
temperature should never be set above 120° F (49° C).
For major water temperature changes:
Remove the O-ring and collar from the stem. Slowly rotate the
valve stem until the water temperature is as desired.
Reinstall the collar on the valve stem so the setscrew is against
the side of the tab.
Reinstall the O-ring and rotate the valve stem counterclockwise to
shut the water off. Recheck the water temperature.
NOTE: After installation, complete the required information on the
valve label.
O-Ring
Setscrew
Tab
Tab
Collar
Collar
Setscrew
Valve
Label
Standard
Valve
High Flow
Valve
Valve
Stem
Kohler Co. 7 1018257-2-B
4. Install the Escutcheon and Handle
CAUTION: Risk of product damage to the K-306-KS valve
assembly. When using this valve in a fiberglass or acrylic
installation, use the Thin Wall Installation Kit (88526).
NOTE: If the wall thickness is greater than 3/4 (1.9 cm), use the
Deep Rough-in Kit (1025388) to add 3/4 (1.9 cm) of depth to the
handle assembly.
Attach the trim adapter to the valve using the two supplied
screws.
Choose the proper stem adapter. If the wall thickness is less than
3/8 (1 cm), use the short stem adapter and screw. If the wall
thickness is 3/8 (1 cm) to 3/4 (1.9 cm), use the long stem
adapter and screw.
Turn the valve stem counterclockwise to the off position.
Align the stem adapter with a flat side horizontal. If the stem
adapter is not properly aligned, the handle assembly will not
align properly. Reposition the stem adapter until the proper
position is achieved.
Attach the stem adapter with the appropriate screw.
Place the escutcheon on the bonnet.
Thread the bonnet on the trim adapter.
Discard
plaster guard
with dome.
Trim
Adapter
Stem
Adapter
Handle
Escutcheon
Screw
Bonnet
Screw
Valve
Stem Adapter should
be parallel to floor.
1018257-2-B 8 Kohler Co.
5. Clean the Screen Washer
Use a clean strap wrench to remove the showerhead from the
shower arm.
Use a thin-bladed screwdriver to carefully pry up the edge of the
screen washer.
Remove and clean the screen washer.
NOTE: Do not attempt to remove the flow control.
Reinstall the screen washer with the tapered end out.
Reinstall the showerhead using a clean strap wrench.
Shower
Inlet
Screen Washer
Kohler Co. 9 1018257-2-B
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Kohler K-T10276-4-BN Installation guide

Category
Storage chests & cabinets & trunks
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI