Read the Instructions First
You should read all safety and operating instructions and labels before operating the TransVu. This Quick Start
Guide is not for use in isolation and should always be used in conjunction with the main user manuals.
If you encounter any problems, contact your supplier. If you have difficulties with this guide contact Dedicated
Micros at the UK office. Addresses and phone numbers are given in the user guides and also in the Contacts
area of our website at:
http://www.dedicatedmicros.com
Servicing
Do not attempt to service this unit yourself because opening or removing covers may expose you to dangerous
voltage or other hazards. Refer all servicing to qualified service personnel.
Lifting and Handling
Always follow health and safety guidelines when lifting the unit from the box or installing the TransVu unit.
Unpacking
Remove all the items from the box and check you have each component listed below.
Your TransVu package contains the following items:
• TransVu unit
• Mounting Plate
• Rubber Shock Mounts
• Installation CD ROM
• Quick Start guide (this document)
If any of these items are missing, please contact Customer Services at your distributor or Dedicated Micros.
Location
• Drilling extra holes in the casing of the unit will immediately invalidate your warranty.
• The unit should be mounted away from any possible places where water may puddle during vehicle
operation as the TransVu casing is not watertight.
• The unit must be mounted horizontally within the vehicle.
• The Multi-pole connector should face the rear of the vehicle
• The unit should be mounted on a secure base free from resonance and secondary vibrations using
the mounting plate provided.
• A suggested fitment area of 350mm x 380mm x 140mm (13¾” x 15” x 5½” ) is recommended.
• Extra space is required around to the plug area to ensure easy removal.
• Refer to TransVu Installation guide for more information.
Connections
Please ensure the following are available and have been tested prior to the installation:
• 12 ~ 24VDC Vehicle Power Source
• Crossed network cable required for web page setup
• Active video signals.
• Correctly terminated cable loom, please see TransVu cabling manual for further info.
• Desk or Laptop PC with CD ROM drive with Internet Explorer 5.5 upwards for unit config
• Note that pin 39 of the Multipole connector provides a switched output of the input voltage NOT
a 12V regulated supply
Making Contact
The first step in configuring your TransVu is to make contact with it using the network. We recommend that you
allocate a fixed IP address to your TransVu, using the method detailed below.
1. Connect the Multi-pole connector with the correctly terminated cable loom to the TransVu
2. Switch the vehicle ignition to ON, the TransVu will now boot up. (If ignition sense is used)
3. Ask your network admin to complete the following with suitable values:
4. Connect the supplied RS232 cable from COM 5 on the TransVu to your PC serial port.
5. On your PC, from the Start menu, select Programs> Accessories> Communications>
HyperTerminal and create a new connection using the COM port and the following settings:
Bits per second – 38400, Data bits - 8, Parity – None, Stop bits – 1, Flow control - None
6. In HyperTerminal, log on to the TransVu by typing +++ and pressing enter.
7.At the Transvu> command prompt, type the following commands, replacing <aaa.bbb.ccc.ddd>
with the values from step 3.
<ESC> means press the Escape key (top left on the keyboard).
<Ent> means press the Enter key.
<ESC>m\ether_ip\aaa.bbb.ccc.ddd <Ent>
<ESC>m\subnet\aaa.bbb.ccc.ddd <Ent>
<ESC>m\gateway\aaa.bbb.ccc.ddd <Ent>
<ESC>m\save <Ent>
reset <Ent> (to restart the TransVu)
8. Connect the TransVu and the configuration PC/Laptop via a seperate Ethernet hub or directly using a Transfer
harness.
9.Open a Web browser and type the IP address of TransVu in the Address Bar.
For example, "http://169.254.123.1/".
If everything is working you should now see the TransVu Viewer Home-Page. If not, check status LEDs on the
front of TransVu, at least one LED should be lit, if not for refer to the cabling manual and check cable.
For further configuration information, refer to the Operation Manual.
Quick Start Guide Media
IP address
- - - . - - - . - - - . - - -
for example169.254.123.1
Subnet mask
- - - . - - - . - - - . - - -
for example 255.255.0.0
Gateway
- - - . - - - . - - - . - - -
for example169.254.123.10
WARNING: Only operate your TransVu from the type of power source indicated on the label.
Failure to do so may cause injury