Lithonia Lighting Solo Installation guide

Type
Installation guide
29 (Use only if NOT
using Swivel 4#)
Figure 1
(Various components
not shown)
42
41
43
44
45
23
40
21
Parts provided in this accessory kit
are identified by filled circles ( 6 )
4) Coupling (2)
4! Pendant
4@ Swivel Adapter (2)
4# Swivel
4$ Washer
4% Tee Nut
4^ Wire Nuts (4) (not shown)
PARTS DESCRIPTION
1^ Extension Collar
1* Convenience Strap
2! Canopy
2# Test Switch / Pilot Light Assy
2$ Test Switch Harness
2% Lamp Harness
2& Lamp Housing Bracket
2( Hex Nipple
IMPORTANT:
This accessory is for use ONLY with Lithonia Lighting Solo™ Exit Signs. Refer to “Installation
Instructions, Solo Exit Signs” (Lithonia Lighting part # EMCSA00752) for important additional information.
INSTALLATION INSTRUCTIONS
Pendant Mount Accessory Kit
for
Solo L.E.D. Exit Signs
When using electrical equipment, basic safety precautions
should always be followed, including the following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
WARNING: FAILURE TO FOLLOW THESE INSTRUCTIONS
AND WARNINGS MAY RESULT IN DEATH, SERIOUS INJURY OR
SIGNIFICANT PROPERTY DAMAGE - For your protection, read and
follow these warnings and instructions carefully before installing or
maintaining this equipment. These instructions do not attempt to cover all
installation and maintenance situations. If you do not understand these
instructions or additional information is required, contact Lithonia Lighting
or your local Lithonia Lighting distributor.
WARNING: RISK OF ELECTRIC SHOCK – NEVER CONNECT
TO, DISCONNECT FROM OR SERVICE WHILE EQUIPMENT IS
ENERGIZED.
WARNING: DO NOT USE ABRASIVE MATERIALS OR OTHER
SOLVENTS. USE OF THESE SUBSTANCES MAY DAMAGE FIXTURE,
WHICH MAY RESULT IN PERSONAL INJURY.
WARNING: RISK OF PERSONAL INJURY – This product may
have sharp edges. Wear gloves to prevent cuts or abrasions when
removing from carton, handling, installing and maintaining this product.
Before wiring to power supply, turn off electricity at fuse or circuit breaker.
Disconnect A.C. power before servicing.
All servicing should be performed by qualified personnel.
Consult your local building code for approved wiring and installation.
Do not use outdoors.
Do not mount near gas or electric heater.
Fixture must be grounded to avoid potential electric shock.
Equipment should be mounted in locations and at heights where it will not
readily be subjected to tampering by unauthorized personnel.
The use of accessory equipment not recommended by the manufacturer
may cause an unsafe condition.
Do not use this equipment for other than intended use.
SAVE THESE INSTRUCTIONS
AND DELIVER TO OWNER
AFTER INSTALLATION
IMPORTANT SAFEGUARDS
!
!
!
!
EMERGENCY LIGHTING SYSTEMS
TEL: 800-334-8694 Fax: 770-981-8141 www.lithonia.com page 1 of 2
NOTE: Swivel is required
ONLY if installing this product
to a non-horizontal ceiling.
U.S. Patents
D602,093 & D602,994
other patents pending
DISCONTINUED
Discard Nut & Spring,
remove Canopy 2!
25
Cut Convenience Strap 1*
& Lamp Harness 2% short
18
approx. 1”
page 2 of 2
EMCSA00753, Rev B
EMERGENCY LIGHTING SYSTEMS
TEL: 800-334-8694 Fax: 770-981 -8141 www.lithonia.com
INSTALLATION INSTRUCTIONS
1. Cut Convenience Strap 1* and Lamp Harness 2% short, leaving
approximately 1” protruding from Canopy 2! (Fig. 2). Keep the
remainder of the Lamp Harness.
(Fig. 2).
2%
1*
2!
2. Remove and discard the nut and spring, and remove the Canopy
om the Panel Assembly
2! fr
3. Remove the two screws and the Lamp Housing Bracket 2& from the
top of the Panel Assembly. Strip approximately 1” of the outer jacket
of the Lamp Harness . Strip the ends of the wires to expose
approximately ½” of uninsulated wire. Extend the Lamp Harness
wires the length of the pendant plus 12 inches by connecting 22-24
gage wires (not provided), using wire nuts 4^.
4. Dress the wire nut connections and the cut end of the Convenience
Strap into the Panel Assembly and replace the Lamp Housing
Bracket 2& and its screws.
5. Assemble Swivel Adapter 4@ to each end of Swivel 4# (if used).
6. Assemble pendant components and Canopy 2! per Figures 1
and 3, dressing the extended Lamp Harness through all.
7. Strip approximately 1” of the outer jacket of the Lamp Harness
remainder 2%. Strip the wire ends and use wire nuts to connect them
to the extended Lamp Harness. IMPORTANT: The polarity of the
lamp circuit must be maintained. Connect the extended Lamp
Harness to its mating plug protruding from the Rough In Section (Fig.
3).
8. Plug Test Switch Harness 2$ onto Test Switch / Pilot Light
Assembly 2# (SD/SDFIFA versions only) (Fig. 3).
9. Guide Canopy onto Extension Collar 1^, dressing harnesses into
the Rough In Section so that no wires are damaged. Tighten Canopy
screws to pull Canopy flush to ceiling.
10. If Swivel is used, plumb fixture by adjusting the angle of the
Swivel assembly, tightening both Swivel screws securely.
Figure 3
(Various components
not shown)
Rough In Section
46
44
42
43
40
41
27
46
Panel Assembly
21
16
29
45
23
25
25
18
Figure 2
(Various components not shown)
24
NOTE: Because the Convenience Strap 1* is
not used in this accessory, it is recommended
that a second person assist by supporting the
panel assembly during installation.
DISCONTINUED