Kichler Lighting 15510CBR User manual

  • Hello! I am an AI chatbot trained to assist you with the Kichler Lighting 15510CBR User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
OUTDOOR USE ONLY
DOM ETRE INSTALLE A L’EXTERIEUR
• Thispowersupplyisforusewithlandscapelightingsystemsonly.
• Donotsubmergetransformer.
• Thisdeviceisacceptedasacomponentofalandscapelightingsystem
wherethesuitabilityofthecombinationshallbedeterminedbyCSAor
localauthoritieshavingjurisdiction.TocomplywithCSArequirement,this
xtureshouldbeinstalledbyaqualiedelectrician.AuCanada.Pourêtre
enaccordavecIES1015CSA.Celuminairedoitêtreinstalléparun
électricienqualié.
• WARNING:Riskofelectricshock,useonlywithlowvoltagelandscape
xturesandaccessories.DOnotusewithswimmingpoolorspalighting
xtures.
• Donotconnecttwoormorepowersuppliesinparallel.
• Foroutdooruseonly.
• NationalElectricalCoderequiresthatwiringwhereconcealedorextended
throughabuildingwallmustbeenclosedinconduit.
• Transformershouldbemountedclosetopowersupply.Extensioncords
shouldnotbeusedwiththisunit.
• WARNING:(forPowerSupplyCordconnectedPOWERUNIT)
RISK OF ELECTRIC SHOCK.Installpowerunit5feet(1.5m)ormore
fromthepool,spa,orfountainwherethepowerunitisinstalled(a)
indoorwithin10feet(3.0m)ofapool,spa,orfountain,or(b)outdoor,
connectpowertounittoareceptacleprotectedbyaGFCI.
• Thisoutdoorpowerunitshallbeconnectedtoa115/120voltcoveredGFCI
receptaclemarked“WetLocation”whileinuse.
• Mounttherain-tighttransformeratleastonefootabovegroundlevelwith
thewireterminalsfacingdown.NOTE:Donotenergizetransformeruntil
installationofsystemiscomplete.
• The12GA,10GAand8GAcableisintendedforshallowburial.Bury
cableaminimumof6inches(152mm)belowthesurface.
NOTE:Ifmorecableisneeded,contactyourlocalKichler
®
Landscape
distributor.12GAcablecanbepurchasedinlengthsof75/22M(15500-BK),
100’/30M(15501BK),250’/76M(15502BK),500’/152(15505BK),and
1000’/304M(15506BK).10GAcableinlengthsof250’/76m(15504BK);
8GAcableinlengthsof250”/76M(15503-BK).
• FindingTransformerLoad:Lowvoltagesystemsrequiretheuseofa
transformertoreducestandard120-VOLTpowerfromyourhometo
12-VOLTS.Todeterminethetransformersizeyouwillneed,addupthe
wattagesofalllampsyouplantouse.Selectatransformerthatmatches
ascloselyaspossibletothetotallampwattage.Forexample,ifyou
have11xturesallratedat24.4watts,youwillneeda300watt
(VA)transformer(11x24.4=268.4watts).Generally,thetotallampload
shouldnotbelessthanone-thirdthetransformerswattagerating,nor
exceeditsmaximumwattagecapacity.Ifyourtotalwattageistoohigh,
eitherdividetheloadbetweentwotransformers,oruseamorepowerful
transformer.
ThisinstructionsheetcoverstheinstallationofthefollowingKichler®Transformers:15510AZT,15513AZT,15514AZT,15M200AZT,
15T200AZT,15TP200AZT.Readtheseinstructionscarefullybeforeinstallingthisunit.
INSTALLATION INSTRUCTIONS
1) Determinedesiredlocationformountingtransformer.NOTE:When
decidinglocationformountingconsiderationshouldbetakenforthe
requirementslistedabove.
2) Markpositionoftopportionofthekeyholeslotlocationattopoftransformer
andtheslotlocatedatbottom.
3) Ifmountingtoasolidsurfacesuchaswood,siding,etc;
A)Drill1/8”diameterpilotholesatpositionsmarkedinStep2.
B)Drivescrewsapproximatelyhalfwayintoholes.
Ifmountingtodrywall:
A)Drill1/4”diameterholesatpositionsmarkedinStep2.
B)Pushplasticanchorsintoholesandtapuntilush.
C)Drivescrewsapproximatelyhalf-wayintoplasticanchors.
4) Sliplargeportionofkeyholeoverheadoftopscrewandallowtransformer
toslidedown,makingsurebottomslotisbehindheadofbottomscrew.
5) Tightenscrewsuntiltransformerissecure.
6) Split12/2.10/2,or8/2cableapproximately3”,andstrip1/2”insulation
offeachwire.12/2.10/2,and8/2cableistheheavyblackcablewhich
allKichler
®
12-voltlowvoltagelightingxtureswillbeconnected.(Reference
abovefordescriptionandpartnumbers).
7) Pushonebarewireineachoftheholesonthebottomsideoftheterminal
blockandtightenscrewsonthefaceoftheterminalblockuntilwiresare
secure.
8) Plugpowersupplycordintostandard115/120voltreceptacle.
NOTE:Thepowersupplycordmustbepluggedintoaweathertight
receptacleequippedwithaGroundFaultInterrupter(GFCI).
INSTALL AND MAINTAIN TO MEET APPLICABLE CODES
COM.
12V
Setting 3 Position Switch
Foroptimumlightoutputthevoltageatsocketshouldbe
between10and12volts.
LOW: Useiftotalwattageislessthanhalfofthetransformer
capacity(i.e.125wattsona300watttransformer),
cabledistancesarelessthan50feetorifthestarting
voltagecomingfromthehouseishigh.
OFF: Turnsoffthetransformerexcept
forthetimer.Thetimerwillstill
functionbutwillnotactivatesystem
duringpresettimes.
HI: Useifthetransformerisfully
loaded(maximumwattage
capacity),cabledistancesare
longorifthestartingvoltageis
lowcomingfromthehouse.
The“HI”or“LOW”position
switchwillactivateboth
thetimerandphotocell
(whenapplicable).
Push Either
LOW OR HI
THREE POSITION SWITCH
TERMINAL BLOCK
FIG.1
NOTE: TIMER INSTRUCTIONS LOCATED ON INSIDE OF
TRANSFORMER COvER.
DateIssued:8/14/09 IS15510-CB
WARRANTY
We Warrant our transformers for ten years on aZt units and lifetime on stainless steel units against defects in material and Workmanship if it is prop-
erly installed and failed under normal operating conditions, provided it is returned to the point of purchase, Where it Will be repaired or, as it may be
determined, to replace the transformer.
/