IS-52283-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
9) Find the appropriate threaded holes on mounng strap[F]. Assemble
mounng screws[M] into threaded holes.
10) Aach mounng strap to outlet box[C] using the strap mounng screws[H].
Mounng strap can be adjusted to suit posion of xture.
11) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole and two raised
dimples, wrap ground wire from outlet box around green ground screw,
and thread into hole.
b) On xtures where a cupped washer is provided,aach ground wire from
outlet box under cupped washer and green ground screw, then thread
into mounng strap.
If xture is provided with ground wire, connect xture ground wire to outlet
box ground wire with wire connector aer following the above steps. Never
connect ground wire to black or white power supply wires.
12) Make wire connecons. Reference chart below for correct connecons and
wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth
(see illus.)
Neutral Wire
13) Push xture to ceiling, carefully passing mounng screws through holes in
canopy[G]. NOTE: Be certain wires do not get pinched between canopy and
ceiling.
14) Use knobs[J] and lockwashers[I] to secure canopy. Tighten to secure.
15) Screw lower decorave tube[R] onto threads protruding from boom of
main body[N].
16) Lower glass[S] down over socket. Secure glass to socket by screwing socket
ring[T] onto threads on outside of socket. Repeat for remaining four (4) glass
pieces.
17) Insert recommended bulbs. (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before
starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance with the Naonal Electrical
Code (NEC) and all local code specicaons. If you are not familiar with code
requirements, installaon by a cered electrician is recommended.
CLEANING:
• Always be certain that electric current is turned o before cleaning.
• Only a so damp cloth should be used. Harsh cleaning products may damage
the nish.
Installaon Instrucons
[A] Stems
[B] Short Threaded
Tubes
[C] Outlet Box
[D] Lockwasher
[E] Hexnut
[F] Mounting Strap
[G] Canopy
[H] Strap Mounting
Screws
[I] Lockwashers
[J] Knobs
[K] Second Loop
[L] Chain Link
[M] Mounting Screws
[N] Main Body
[O] First Loop
[P] 9-inch Tube
[Q] 4.5-inch Tube
[R] Lower Decorative
Tube
[S] Glass
[T] Socket Ring
RIGID STEM MOUNT
1) Pass xture wires from main body[N] through 9-inch tube[P] and screw tube
onto threads protruding at top of main body.
2) Pass xture wires from 9-inch tube through 4.5-inch tube[Q] and screw tube
into top of 9-inch tube.
3) Pass xture wires through desired number of stems[A] and screw stems
together using supplied short threaded tubes[B].
NOTE: A minimum of one (1) 12-inch stem must be used when mounng
xture. Pass xture wire through remaining stems and screw stems together.
NOTE: Thread locking compound must be applied to all stem threads as
noted with symbol (4) to prevent accidental rotaon of xture during
cleaning, relamping, etc.
4) Screw rst stem into coupling aached to 4.5-inch tube[Q].
5) Pass xture wires from last stem through one short threaded tube[B].
6) Screw short threaded tube into top of last stem.
7) Pass xture wires through hole in canopy[G]. Lower canopy down towards
stem. Pass hole in canopy over end of short threaded tube on top of stem.
8) Pass xture wires through lockwasher[D] and then through hexnut[E]. Place
lockwasher onto end of short threaded tube protruding from inside canopy
and thread hexnut onto tube.
NOTE: Fixture wires should not be cut shorter than 20 inches from above the
canopy.
Installaon Instrucons (connued)
LOOP / CHAIN LINK MOUNT
1) Follow steps 1 - 4 from “Rigid Stem Mount” Instrucons.
2) Pass xture wires from last stem through short threaded tube[B] and through
rst loop[O]. Screw short threaded tube into top of last stem and into rst loop.
3) Pass xture wires through second loop[K], short threaded tube, and hole in
canopy[G]. Screw short threaded tube into end of second loop.
4) (If second loop is already aached to canopy, proceed to next step). Insert
short threaded tube at end of second loop through hole in canopy. Thread lock
washer[D] onto short threaded tube protruding from inside canopy. Pass xture
wires through hexnut[E] and thread hexnut onto end of short threaded tube.
NOTE: Fixture wires should not be cut shorter than 20 inches from above the
canopy.
5) Aach open chain link[L] to loop at end of stem(s) and to loop on canopy. Once
aached, close the open chain link by placing a piece of cloth over the open link
and using a pair of pliers to gently squeeze the link closed.
6) Follow steps 9 - 17 from “Rigid Stem Mount” Instrucons.
Q
P
R
N
S
T
K
O
L
B
A
►
►
►
B
A
J
I
B
G
C
F
M
H
D
E