Intratone 12-0110-EN User guide

Type
User guide
Installation and user guide for an auxiliary 1, 2, 3 or 4-door card of the Intratone range
Page 1 / 2 EN-V233 - 0006 - AA
Installation and user guide for an auxiliary 1, 2, 3 or 4-door
card of the Intratone range
Presentation of the EEN-CR auxiliary door card
This card opens auxiliary relays that will control a door or a light etc.
Two potentiometers control the opening of the auxiliary door. The first potentiometer sets the
delay before opening, the second the door unlock time.
Two switches indicate the auxiliary door's address: 1 / 2 / 3 or 4. The third switch indicates the
type of door pushbutton (NO/NC).
Finally, this card is fitted with a door entry pushbutton.
Technical specifications
Power supply 12 to 24 VDC / 50 mA
Max cabling distance 300 m in 0.80mm
Delay before opening from 0 to 60 sec.
(approx)
Door unlock time from 0.2 to 60 sec.
(approx)
1
2
3
Switch 1 Switch 2
2
Door No.
OFF OFF 1
st
ON OFF 2
nd
OFF ON 3
rd
ON ON 4
th
Switch 3 Button type
OFF Normally Open
ON Normally Closed
Potentiometer
0.2 sec
5 sec
area
Installation and user guide for an auxiliary 1, 2, 3 or 4-door card of the Intratone range
Page 2 / 2 EN-V233 - 0006 - AA
Installation with an IntraCode central unit
Installation with independent GSM unit (without central
unit)
GSM edge module
+
-
D+
D
-
A
-
A+
2
3
4
1
Ancillary
card
Relay
ancillary
door
De
lay potentiometer
- +
Unlock time potentiometer
8
9
7
R
T
C
To ancillary
door
Proximity reader
(OPTIONAL)
To other
ancillary
cards
5
6
To ancillary
door
pushbutton
Intracode mini central unit
+
-
D+
D
-
C
R
T
2
3
4
1
Ancillary
card
Relay main
door
Relay
ancillary
door
Delay potentiometer
- +
Unlock time potentiometer
8
9
7
R
T
C
To ancillary
door
proximity
reader
1
2
3
4
5
6
To other
ancillary
cards
5
6
To ancillary
door
pushbutton
To main
door
Proximity
reader
  • Page 1 1