IFM EVC04A, EVC08A, EVC14A Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the IFM EVC04A Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Operating instructions
(Ex protection related part)
M12 connector
EVCxxA
11476461 / 0009 / 2022
GB
EVCxxA M12 connector
2
1 Safety instructions
Remarks for safe use in hazardous areas.
The product must only be installed, connected and set up by qualified staff. The qualified staff must
have knowledge of types of protection, regulations and provisions for apparatus in hazardous
areas.
The classification and marking of the product must be suitable for the application.
Adhere to the respective national regulations and provisions as well as the relevant installation
regulations.
Observe applicable documents.
2 Intended use
Use in hazardous areas according to the classification:
ATEX classification Marking Permissible ambient temperature
II 3G Ex ec IIC Gc -20…60 °C
II 2D Ex tb IIIC Db IP65/IP67 -20...60 °C
Ambient temperature range for connection cables and jumpers with angled M12 plug and angled M12
sockets.
Type examination certificate:
EU: BVS 08 ATEX E109 U
IEC: IECEx BVS 08.0041 U
The requirements of the following standards are met:
EN IEC 60079-0:2018, EN IEC 60079-7:2015/A1:2018, EN 60079-31:2014
IEC 60079-0:2017, IEC 60079-7:2015/A1:2017, IEC 60079-31:2013
3 Installation
uProtect the product from destruction.
uAvoid electrostatic charging on the product.
uLay the cable firmly and protect it against damage.
uAvoid direct exposure to high levels of UV light (sunlight). Mount the product in a protected place.
uOnly open or close M12 fittings in a sufficiently clean environment.
uAlways close the connectors with a counterpart. They may be left open in the field only briefly for
servicing purposes.
3.1 Special conditions for safe operation
uAlways refer to the operating instructions for the marking, as it may not be fully applied to the
product due to lack of space.
uDo not separate the connector when energized.
uSecure the connector by tightening the coupling nut sufficiently. Tightening torque 1.2...1.5 Nm.
1. Hand-fasten the coupling nut (0.4...0.5 Nm).
M12 connector EVCxxA
3
2. Then turn by 3 notches using a spanner across the flats 14.
The product has been tested in accordance with EN 60079-0 for group II and for a low mechanical risk
with an impact energy of 4 joules.
The product conforms to the requirements for an M12 connector as set forth in EN 61076-2-101. The
counterpart must also conform to this standard.
4 Maintenance, repair and disposal
No modifications or repairs may be made to the product.
uIn case of a fault please contact the manufacturer.
uIf required, request data sheets or type examination certificates / certificates from the manufacturer
(Ò cover sheet / back).
/