Bradley S19-210BF Installation guide

Category
Sanitary ware
Type
Installation guide
Installation
P.O. Box 309, Menomonee Falls, WI USA 53052-0309
PHONE 800.BRADLEY (800.272.3539) FAX 262.251.5817
bradleycorp.com
215-619BF Rev. S; ECM 10-05-031
© 2010 Bradley Corporation
Page 1 of 5 8/27/10
S19-210BF
Barrier Free Stainless Steel
Eyewash
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Assembly of Components . . . . . . . . . . . . . . . . . . . . . . . 4
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2
S19-210BF Installation
8/27/10 Bradley Corporation 215-619BF Rev. S; ECM 10-05-031
WARNING
Read this installation manual completely to ensure proper installation, then file it
with the owner or maintenance department. Compliance and conformity to drain
requirements and other local codes and ordinances is the responsibility of the installer.
Separate parts from packaging and make sure all parts are accounted for before
discarding any packaging material. If any parts are missing, do not begin installation
until you obtain the missing parts.
Flush the water supply lines before beginning installation and after installation is
complete. Test the unit for leaks and adequate water flow. Main water supply to the
eyewash should be “ON” at all times. Provisions shall be made to prevent unauthorized
shutoff.
The ANSI Z358.1 standard requires an uninterruptible supply of flushing fluid at a
minimum 30 PSI (0.21 MPa) flowing pressure. Flushing fluid should be tepid per ANSI
Z358.1.
The inspection and testing results of this equipment should be recorded weekly
to verify proper operation. This equipment should be inspected annually to ensure
compliance with ANSI Z358.1.
Workers who may come in contact with potentially hazardous materials should be
trained regarding the placement and proper operation of emergency equipment per
ANSI Z358.1.
For questions regarding the operation or installation of this product, visit www.
bradleycorp.com or call 1-800-BRADLEY.
Product warranties and service parts information may also be found under ”Products”
on our web site at www.bradleycorp.com.
Installation
THIS
SIDE
UP
Packing List
P.O. Box 309, Menomonee F
alls,
WI 53051
R
TEST THIS
UNIT EACH
WEEK
Test-operate valv
e(s) each week and sign
below.
Report an
y malfunctions immediatel
y.
Ventil(e) wöc
hentlich im
Testbetrieb prüfen,
bestätigt
durch Untersc
hrift. Jeglic
he Störung sofor
t melden.
Date
Datum
Date
Signed
Unterschrift
Signe
Date
Date
Date Signed
Signed
Signed
DIESES GERÄT 1ST
WÖC
HENTLICH ZU
PRÜFEN.
ESSAI HEBDOMA
DAIRE
Test le fonctionnement des v
alves chaque semaine et
signe en bas. S'il y à quelqu
e chose qui ne v
a pas fait
un rappor
t immédiatement.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
3
Installation S19-210BF
Bradley Corporation 215-619BF Rev. S; ECM 10-05-031 8/27/10
Installation
Supplies Required:
• (3)3/8"flooranchorsandbolts
• Pipesealant
• Pipingto1/2"NPTwatersupplyinlet
• Pipingto1-1/4"NPTdrainoutlet
• Sign-mountinghardware
NOTE: Local codes may require the installation of
a backflow prevention valve to complete proper
installation. Compliance with local codes is the
responsibility of the installer. Valve must be tested
annually to verify that it is functioning properly.
Backflow prevention valves are not included with
the fixture and may be supplied by the contractor
or purchased from Bradley Corporation.
Step 1: Secure base to floor
1. Installthreesuitableanchors(suppliedby
installer)for3/8"boltsinthefloor.
2. Boltthebasetotheflooranchorsusing3/8"
bolts(suppliedbyinstaller).
Step 2: Assemble eyewash
1. Assembleeyewashcomponentsasshown
onpage4.
• Applypipesealant(suppliedbyinstaller)to
allmale-threadedpipejoints.
• Usetherubbergrippadprovidedora
strapwrencharoundpipeswhentightening
topreventmarring.Placethegrippadon
thepipe,thenputthewrenchoverthegrip
padandturnthepipewiththewrench.
• Usecautionwhenconnectingitems3,4.2
and5.Handtightplus1/8turnissufficient.
Step 3: Connect water supply
1. Connectthewatersupplypiping(supplied
byinstaller)tothe1/2"NPTinletonthe
eyewash.
2. Connectthedrainpiping(suppliedby
installer)tothe1-1/4"NPTdrainoutletonthe
eyewash.
3. Mountthesafetysigntothewallusingsign-
mountinghardware(suppliedbyinstaller).
4. Openthewatersupplylinesandtestfor
leaksandadequatewaterflow.
NOTE: All dimensions assume standard thread engagement.
Variations in manufacturing allow for +/- 1/8”
(3mm) per threaded joint. To find the tolerance of
a dimension, add the number of thread joints in
between a dimension and multiply it by 1/8” (3mm).
27"
(686mm)
Ø 10-3/4"
(273mm)
18-3/4"
(476mm)
15-3/4"
(400mm)
6"
(152mm)
31"
(787mm)
5-5/8" (143mm)
Ø9"(229mm)Flange
with(3)Ø3/8"(10mm)
HolesonØ8"(203mm)
Bolt Circle
4
S19-210BF Installation
8/27/10 Bradley Corporation 215-619BF Rev. S; ECM 10-05-031
Assembly of Components
4.261
4.1
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
2
3
5
6
7
1
8
9
P.O. Box 309, Menomonee Falls, WI 53051
R
TEST THIS UNIT EACH WEEK
Test-operate valve(s) each week and sign below.
Report any malfunctions immediately.
Ventil(e) chentlich im Testbetrieb prüfen, bestätigt
durch Unterschrift. Jegliche Störung sofort melden.
Date
Datum
Date
Signed
Unterschrift
Signe
Date
Date
Date Signed
Signed
Signed
DIESES GERÄT 1ST CHENTLICH ZU PRÜFEN.
ESSAI HEBDOMADAIRE
Test le fonctionnement des valves chaque semaine et
signe en bas. S'il y à quelque chose qui ne va pas fait
un rapport immédiatement.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
4.22
4.23
4.24
4.25
4.25
4.26
4.27
4.28
4.21
4.21
4
NOTE: Items 4.1–4.12 come preassembled as Item 4.
1-1/4" NPT
Drain Outlet
1/2" NPT
Supply Inlet
Use caution when
connecting Items
3, 4.2 & 5. Hand
tight plus 1/8 turn
is sufficient.
5
Installation S19-210BF
Bradley Corporation 215-619BF Rev. S; ECM 10-05-031 8/27/10
Parts List
1 131-059 1 Base
2 169-727 1 PipeTee1-1/4"NPT
3 113-1101 1 Pipe1-1/4"NPTx19-3/4"
4 S90-373 1 EyewashAssembly
4.1 124-028 1 Gasket
4.2 S39-562 1 EyewashPipeSub-Assembly
4.21 169-025 2 90°StreetElbow1/2"NPT
4.22 111-084 1 EmergencyEyewashInlet
4.23 113-1104 1 Pipe1-1/4"x16-1/2"
4.24 169-1020 1 EmergencyEyewashHub
4.25 113-006LQ 2 Pipe1-1/2"x3-1/2"
4.26 S27-282 1 1/2"BallValvewithNut
4.261 110-215 1 JamNutonly
4.27 269-1829 1 Pipe1/2"NPTx13-1/4"
4.28 169-726 1 Union,1/2" Female
4.3 187-053 1 StainlessSteelBowl
4.4 173-009 1 CupStrainer
4.5 S21-073 1 SupplyPipeAssembly
4.6 113-1159 1 Drain Spacer
4.7 S05-100 1 EyewashYokeAssembly
4.8 107-371 2 TetheredDustCover
4.9 269-651 1 SwivelStem
4.10 124-055 2 QuadRing
4.11 139-087 1 SprayRingAssembly
4.12 110-199 1 AcornNut
5 169-725 1 Reduc’gBushing1-1/4"x1/2"NPT
6 128-135 1 Handle, Plastic
7 142-002DA 1 Lockwasher
8 114-051 1 SafetySign
9 204-421 1 EmergencyInspectionTag
10 269-915 1 GripPad(notshown)
Item Part No. Qty Description
Item Part No. Qty Description
PrepackS45-1786includesitems4.9,4.10,4.11,4.12
PrepackS39-397includesitems4.5,4.6,4.7,4.8,4.9,4.10,4.11,4.12
PrepackS45-122includesitems4.26,4.261,6,7
PrepackS45-123includesitems4.261,6,7
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Bradley S19-210BF Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI