Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
setting .
At the same time, hold the knob down until
the burner ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operation.
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught,
an interruption in the gas delivery, boiling
over of liquids, etc.).
1.
Removable grids
2.
Semi-rapid burners
3.
Triple crown burner
4.
Auxiliary burner
5.
Right rear semi-rapid
burner control knob
6.
Left rear semi-rapid
burner control knob
7.
Triple crown burner
control knob
8.
Front auxiliary burner
control knob
9.
Front semi-rapid burner
control knob
Symbols
Shaded
circle
Tap closed
Large
flame
and star
Maximum opening/delivery
and electric ignition
Small
flame
Minimum opening or
reduced delivery
3gb66051.fm Page 1 Wednesday, March 17, 2004 12:37 PM
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
Note: In case of installation of a hood above the cooking hob, please refer to the hood
instructions for the correct distance.
Important:
Installation of this product requires masonry and/or carpentry work. Therefore, it must
be carried out by a competent technician. The appliance may be installed on various
surfaces, such as brickwork, metal, solid wood and plastic laminated wood, provided
they are made of heat resistant materials (T 90°C).
Installation of flush fitting model
Provide an opening in the worktop in accordance with the dimensions shown in the figure, leaving a
minimum clearance of 50 mm from the rear edge. The lower face of the hob must be accessible after
installation.
The appliance can be positioned against walls which are higher than the worktop, leaving the minimum
clearance (
A
) shown in the figure, in order to avoid damages caused by excessive heat. Make sure there is
a minimum vertical clearance of
750 mm
between the burner flames and an overhead shelf (fig.1).
This type of appliance requires milling a 2.5 mm deep recess on the worktop, following the measures
indicated in
figure 2
. Before fitting the hob, it is necessary to apply the sealing tape
E
supplied with it
to the full length of the milled surface
(fig. 3)
. Then place the hob on the milled surface and secure it to
the support structure using screws and brackets
C
or
D
(depending on the thickness of the worktop),
until it is flush to the worktop.
Brackets
C
should be used to secure the hob to a top which is 20 to 30 mm thick, whereas brackets
D
should be used for a worktop 30 to 50 mm thick.
Important:
tighten the brackets that secure the hob to the worktop by hand. Do not overtighten.
if the worktop is made of wood or similar materials, the milled surface must be protected with
primer (protective paint) before applying seal E.
Fig.1
Fig.2
Fig.3
3gb66051.fm Page 2 Wednesday, March 17, 2004 12:37 PM
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
Type of
burner
Injector
marking
Rated heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat
capacity
Pcs-kW
Gas pressure
min. rat. max.
NATURAL GAS
(Methane) G20
Triple crown
semi-rapid
auxiliary
133
97
72
3.50
1.75
1.05
333 l/h
167 l/h
100 l/h
1.50
0.45
0.35
17 20 25
LIQUID PETROLEUM
GAS
(Butane) G30
Triple crown
semi-rapid
auxiliary
94
65
50
3.50
1.75
1.05
254 g/h
127 g/h
76 g/h
1.60
0.45
0.35
20 28-30 35
LIQUID PETROLEUM
GAS
(Propane) G31
Triple crown
semi-rapid
auxiliary
94
65
50
3.50
1.75
1.05
250 g/h
125 g/h
75 g/h
1.60
0.45
0.35
25 37 45
Type of gas used
Appliance
model
Total rated heat
capacity
Pcs-kW
Total rated
consumption
Air required
for burning
m
3
/h
G20 20 mbar 5 gas 9.80 933 l/h 19.6
G30 28-30 mbar 5 gas 9.80 712 g/h 19.6
G31 37 mbar 5 gas 9.80 701 g/h 19.6
3gb66051.fm Page 3 Wednesday, March 17, 2004 12:37 PM
3gb66051.fm Page 4 Wednesday, March 17, 2004 12:37 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Whirlpool AKM 481 IX Program Chart

Type
Program Chart

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI