ZKTeco ZL500 is a versatile electronic door lock designed for enhanced security and convenience. With its 5 latches and compatibility with American Standard Mortise, it offers reliable locking mechanisms for various door types. It operates on four Alkaline AA batteries, ensuring uninterrupted performance. ZL500 features keyless entry via authorized MiFare cards, providing a secure and touchless solution. It also includes traditional key access for manual unlocking in case of emergencies.

ZKTeco ZL500 is a versatile electronic door lock designed for enhanced security and convenience. With its 5 latches and compatibility with American Standard Mortise, it offers reliable locking mechanisms for various door types. It operates on four Alkaline AA batteries, ensuring uninterrupted performance. ZL500 features keyless entry via authorized MiFare cards, providing a secure and touchless solution. It also includes traditional key access for manual unlocking in case of emergencies.

Installation Guide
Model: ZL500
Lock Body: American Standard Mortise with 5 Latches
Version: 1.0
English
Cautions
A new lock is defined as always in open mode until it is locked once by a MiFare card.
Please register an authorised card, a time sync card, and a room card initially for the new lock.
The lock is equipped with keys for manual unlocking. Remove the keys from the package and keep them
in a safe place.
To power on the lock, four alkaline AA batteries (not included) are required. Non-alkaline and
rechargeable batteries ARE NOT RECOMMENDED.
Do not remove the batteries when the lock is in working state.
When the battery power is low, the lock will beep to remind the user to replace the batteries. Make sure
not to mix up the polarities while replacing the batteries.
Avoid contact with corrosive substances. Do not hang any object on the handle.
The built-in software manages the operation of access cards. Please refer the software user manual.
For further queries, please contact the seller.
1.
2.
3.
4.
5.
6.
7.
8.
9.
1
Packing List
Outdoor Unit
Hex Wrench
Screw A
Strike
Plate
Mortise CylinderGuidance
Plate
Box
Indoor Unit
Spindle B Screw B
Studs
Screw C
Vacuum Sucker
Key
Spindle A
Screw D
Installation Diagram
2
Battery Cover
Strike Plate
Outdoor Unit
Spindle B
Screw B
Mortise
Studs
Spindle A
Hex
Wrench
Cylinder
Screw A
Guidance
Plate
Screw D
Box
Screw Cover
Screw C
Battery
Indoor Unit
Door Properties
Door Thickness Spindle A Spindle B Screw C
35 to 45 mm 40 mm 75 mm 25 mm
1. Door Thickness
Note: If the door is thicker than 45 mm, this lock will not be suitable. Please contact the sales person for queries.
2. Door Opening Direction
User Location
Mortise
Strike Plate
Mortise
Mortise
Strike Plate
Mortise Strike Plate
Strike Plate
Left Inward Right Inward
Left Outward Right Outward
Note: Please install the Mortise and Strike Plate according to the above illustration.
3
4
Installation Procedure
Drill holes on the door
Door thickness
35 to 45 mm
Backset
62.5mm
Center line of the handle
Desired handle height
Place the installation template at the desired handle height.
1)
Mark the holes to be drilled and drill the marked places.
2)
1
Remove the Guide Plate
Unscrew the Screw D and remove the Guide Plate.
5
2
Installation of Mortise
Secure the Mortise with Screw A and Screw D. Make sure the latch angle faces the door post.
6
Screw A Screw D
3
Installation of Lock Cylinder
7
Hex WrenchCylinder
Screw B
Use the Hex Wrench to tighten the Screw B to secure the Cylinder.
4
Installation of Spindles and Studs
2) Insert the Spindle A and Spindle B into the drilled holes.
Note: Make sure that the two triangles are horizontally aligned to each other.
8
5
Studs
Spindle B
Spindle A
1) Insert the Spindle A into the clutch, and make sure the triangles point each other. Secure the studs on the
Outdoor Unit.
Installation of Outdoor Unit and Indoor Unit
Screw C
9
6
2) Attach the Outdoor Unit and Indoor Unit on the door, and then secure them with Screw C.
1) Connect the cables of the Indoor Unit, Outdoor Unit, and Mortise.
Battery and Cover Placement
Insert four Alkaline AA batteries and cover them with the battery cover. Then, cover the Screw C with a Screw
Cover.
10
7
3 mm
22 mm
125 mm
89 mm
25 mm
Installation of Strike Plate and Box
1)
2)
Make sure the Strike Box is aligned with the latch bolt. Then, use the installation template to drill the holes.
Align the Strike Plate and Box with the drilled holes and secure them with Screw A.
11
Screw A
8
12
Test the lock with key
Step 1: Remove the cover on the key hole with the Vacuum Sucker.
Step 2: Insert the key into the key hole and rotate it by 90°, then rotate down the handle to open the door.
9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

ZKTeco ZL500 Installation guide

Category
Split-system air conditioners
Type
Installation guide

ZKTeco ZL500 is a versatile electronic door lock designed for enhanced security and convenience. With its 5 latches and compatibility with American Standard Mortise, it offers reliable locking mechanisms for various door types. It operates on four Alkaline AA batteries, ensuring uninterrupted performance. ZL500 features keyless entry via authorized MiFare cards, providing a secure and touchless solution. It also includes traditional key access for manual unlocking in case of emergencies.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI