Function Block Inputs (continued)
Item Type Range Description
Snsr Pwr Bus —— Voltage supplied to the swash plate angle sensor.
The function block uses the Snsr Pwr and SIG1 signals and the EE_Cal_Min and EE_Cal_Max values to
make a ratiometric calculation of the swash plate angle sensor's position and its faults.
The function block receives this value through either a Volt signal or a Voltage signal:
•
On an MC controller, the value inputs through the Volt signal.
•
On an SC controller, the value inputs through the Voltage signal.
Volt
U16 4,750–5,250 Voltage supplied to the swash plate angle sensor.
1,000 = 1,000 mV.
Voltage
U16 4,750–5,250 Voltage supplied to the swash plate angle sensor.
1,000 = 1,000 mV.
SIG1 Bus —— Signal from the swash plate angle sensor that indicates, through voltage, the position of the pump
swash plate.
The function block uses the Snsr Pwr and SIG1 signals and the EE_Cal_Min and EE_Cal_Max values to
make a ratiometric calculation of the swash plate angle sensor's position and its faults.
The function block receives this value through either a Volt signal or a Voltage signal:
•
On an MC controller, the value inputs through the Volt signal.
•
On an SC controller, the value inputs through the Voltage signal.
Volt U16 0–5,250 Signal from the swash plate angle sensor that indicates the position of the pump swash plate.
1,000 = 1,000 mV.
Voltage U16 0–5,250 Signal from the swash plate angle sensor that indicates the position of the pump swash plate.
1,000 = 1,000 mV.
SIG2 Bus —— A second signal from the swash plate angle sensor that indicates, through voltage, the position of the
pump swash plate.
The function block monitors the SIG2 signal to ensures the integrity of the SIG1 signal.
The function block declares a fault whenever the difference between the SIG1 and SIG2 signals
becomes:
•
Greater than 600 mV.
•
Less than 400 mV.
The function block receives this value through either a Volt signal or a Voltage signal:
•
On an MC controller, the Volt signal inputs this value.
•
On an SC controller, the Voltage signal inputs this value.
Volt U16 0–5,250 Second signal from the swash plate angle sensor that indicates the position of the pump swash plate.
1,000 = 1,000 mV.
Voltage U16 0–5,250 Second signal from the swash plate angle sensor that indicates the position of the pump swash plate.
1,000 = 1,000 mV.
Outputs
Function Block Outputs
Item Type Range Description
Status U16 —— Reports the status of the function block.
See Status and Fault Logic on page 7 for more information.
Fault U16 —— Reports the faults of the function block.
See Status and Fault Logic on page 7 for more information.
Pct U16 0–10,000 Swash plate angle as a percentage.
•
0 = Minimum swash plate angle.
•
10,000 = Maximum swash plate angle.
10,000 = 100.00%
Displ U16 0–200 Pump displacement based on the measured angle of the swash plate.
100 = 100 cc
User Manual PLUS+1 Compliant S45 Angle Sensor Function Block
S45_Angle_Snsr Function Block
L1409288 • Rev AA • June 2014 5