For warranty informaon please visit: hp://www.kichler.com/warranty
Para informacion de la garana por favor visite: hp://www.kichler.com/warranty
IS-16232-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
Kichler 16232 & 16233 Installaon Guide
LED Wall Pack
IMPORTANT: Read before removing xture from carton. Retain
for future reference.
SAFETY: This xture must be wired in accordance with the
NATIONAL ELECTRICAL CODE (NEC) and applicable local codes
and ordinances. A person familiar with the construcon and
operaon of the product and the hazards involved must install
this product. A qualied licensed electrician should complete all
work. Proper grounding is required for safety.
WARNING: Make certain power is OFF before installing or
maintaining xture.
RISK OF INJURY: Fixture may become damaged and/or unstable
if not installed properly.
Cauons:
Installaon Instrucons:
Fixture Diagram
NOTE: Turn o electrical supply at the breaker. Follow all
local electrical codes for wiring and grounding requirements.
NOTE: This xture is intended to be surface mounted on to a
wall in the lens down posion.
Tools Required: Phillips Screw Driver, Security Torx T-20 Bit
& Driver, Electric Drill, Drill Bit Set, Wire Strippers & Cuers
1) Unpack xture and ensure that there are no damaged
parts.
2) Open xture by removing the T-20 Security Torx screws on
the side of the xture.
3) Disconnect orange connector and remove LED and frame
assembly to allow for easier installaon.
4) Inspect the 3 mounng hole locaons (Item A on g. 2)
and ensure that there are no components over them.
5) In order to mount the xture the backplate has to be
pierced at the mounng locaons. Use an appropriate
sized drill bit for the mounng screws up to 5/16”.
6) Align the backplate and mount securely with mounng
hardware appropriate for surface.
7) If electrical connecons are going to be made from a
conduit pipe, remove one of the conduit plugs from the
base and thread NPS conduit pipe into locaon.
8) If electrical connecons are going to be made through a
juncon box, drill the appropriate holes (Item C in Fig.2)
for the sized juncon box.
9) Connect leads from back of xture to the power supply
leads: Green to green (ground), black to black (hot), white
to white(neutral).
10) Reaach frame and glass assembly to base by slipping it
over the barrel pins.
11) Reconnect orange connector and reaach the frame
assembly using the Torx Screw.
MOUNTING:
The back plate has a cast-in drill and knock-out template
to match any standard recessed juncon box, three 5/16”
knock-outs for mounng holes A and three 1/2” NPS
tapped holes D for surface conduit or photocontrol unit.
A – 5/16” Diameter Knockouts
B – 9/16” Diameter Knockouts
C – Knockouts for #10 screw
D – 1/2” NPS Tapped Holes
Use weatherproof silicone sealant to seal all holes and
gaps between xture and mounng surface.
This device complies with part 15 of the FCC Rules. Operaon is
subject to the following two condions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including
interference that may cause undesired operaon.
Note: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protecon
against harmful interference in a residenal installaon. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instrucons,
may cause harmful interference to radio communicaons.
However, there is no guarantee that interference will not occur
in a parcular installaon. If this equipment does cause harmful
interference to radio or television recepon, which can be
determined by turning the equipment o and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separaon between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
FCC Informaon:
RISK OF FIRE, EXPLOSION AND ELECTRIC SHOCK
• This product should be installed, inspected, and maintained by a qualied
electrician only, in accordance with the NEC (Naonal Electric Code) and all
local codes.
• Turn o electrical power before inspecon, installaon or removal.
• Use only UL (or other NRTL) approved wire for input/output connecons.
Minimum size 18 AWG or 14 AWG for connuous runs.
• Make sure LEDs and drivers are cool to touch when performing maintenance.
Make sure the supply voltage is the same as the rated voltage of the luminaire.
• Do not install in a hazardous atmosphere, except where the ambient
temperature does not exceed the rated operang temperature of the xture.
• Keep ghtly closed when in operaon
Electrical Requirements
The LED driver must be supplied with 120 to
277V, 50/60 Hz and connected to an individual,
properly grounded branch circuit protected by a
20 Ampere circuit breaker. Use min. 90°C supply.
Grounding Instrucons
The grounding and bonding of the overall
system shall be done in accordance with
NEC Arcle 600 and local codes
INSTALLATION AND SERVICE INSTRUCTIONS
SML-106/706/707/708 LED Wallpack
TEMPLATE
GR
GR
GND
A
A
A
C
B
31/4" OCT.BOX
4" OCT. BOX
D
D
D
TROUBLE ING CHECKLIST: If the light does not work.
Figure 2
Figure 1
Black
Line
White
Neutral
Green
Ground
FIXTURE