L Y - 1 0 K G F QSG
4
2.
I n s t a l l E S C .
(1)
Mount E S C o n themounting plate. Connect E S C and motor withtheconversion c a b l e s .
Connect E S C withthepower m o d u l e o f LY-10KGF, as showni n Fig.2.2.1 and Fig.2.2.2:
Fig.2.2.1 Fig.2.2.2
Note:Keep a loose cableconnection between motor andESC,otherwise itwill affect theaccuracy of thetest.
(2). Connect JST P l u g . E S C signal cable connects to“OUT”port o n thecontrol module, as shown
i n Fig.2.2.3:
F i g . 2.2.3 Connection ofs i g n a l c a b l e s
Note:“ O u t ” and“read+”comew i t h 5Voutput for thereceiver or ESCof s p e c i a l requirements. Disconnect themifd o n o t u s e
thereceiver or ESC.
3.
Installation o f I n f r a r e d Temperature Probe
LY-10KGF measures temperature withinfrared detection. Install theprobe parallel tothetest
surface and keep thedistance around 1-3cm (keep thel e n s c l e a n without g r e a s y covered).
Thetemperature probe detects temperature without touching theobject. Therewill b e a
deviation d u e totheemissivity o f theobject. Therefore, thetestarea should b e i n d a r k (black tape
o r black m a r k e r c a n b e used). Besides, theprobe m a y also detect theambient temperature, install
thesensor inside theb r a c k e t and keep g o o d ventilation,as showni n Fig.2.3.1 and Fig.2.3.2: