Interlogix 6250 Series Installation guide

Category
Motion detectors
Type
Installation guide

Interlogix 6250 Series is a versatile PIR motion detector that can be tailored to fit your specific security needs with a range of specialized masking plates to avoid false alarms. It boasts multiple detection patterns including wide angle, single spot, vertical barrier and pet alley, making it suitable for various applications. With a 30' x 30' capture zone, it can effectively cover large areas. Installation is simple with the included masking kit and adjustable LED indicator for easy walk testing.

Interlogix 6250 Series is a versatile PIR motion detector that can be tailored to fit your specific security needs with a range of specialized masking plates to avoid false alarms. It boasts multiple detection patterns including wide angle, single spot, vertical barrier and pet alley, making it suitable for various applications. With a 30' x 30' capture zone, it can effectively cover large areas. Installation is simple with the included masking kit and adjustable LED indicator for easy walk testing.

6250 Series SureShot PIR
Installation Instructions
Models 6255, 6257
Lens
Mask
Pyro shield
Back cover
Circuit
board
guides
Cable
strain
reliefs
Sliding
LED cover
Front cover
Masking kit
Circuit
board
assembly
V
E
R
T
I
C
A
L
B
A
R
R
I
E
R
PET
ALLEY
ROTATE LENS
180
o
WIDE
ANGLE
SPDT
U
L
LISTED
SENTROL
Avoid False Alarm Sources
Sunlight or
reflected sunlight
Pets
Intermittent
heat sources
Hot or cold air
directed onto sensor
6. Choose which masking plate you need, if any. Insert
behind lens on front cover by pressing over four mounting
pins. Once front cover is installed the masking plate will be
held tight against the lens.
Note: Masking plates have two notches to prevent
incorrect installation. One notch matches a rib
in the front cover. The second notch matches a
dimple in the lens.
INSTALLING THE SURESHOT
1. Remove front cover by gently prying apart at bottom. Front
cover hinges at top.
2. Remove circuit board assembly by holding pyro shield and
pulling out of back cover.
3. Mount back cover to ceiling, wall or corner. For wall
mounting, make sure "up" arrow is pointing up. Use
appropriate mounting knockouts.
Mounting
UP
MADE IN U.S.A.
1-800-547-2556
Knockouts for
Wall or Ceiling
Mounting
Knockouts for
Corner Mounting
Wiring Knockouts
Wiring Knockouts
Knockouts for
Wall or Ceiling
Mounting
Knockouts for
Wall or Ceiling
Mounting
Knockouts for
Corner Mounting
Knockouts for
Wall or Ceiling
Mounting
4. Snap circuit board assembly back into back cover by
aligning lower edge of board with circuit board guides and
pressing into place.
5. Connect wires per "wiring" diagrams on following page. A
wiring diagram is also included on the inside of the front
cover. You can strain relieve your wire cable by wrapping
it around the strain relief posts in the lower corners of the
back cover.
Note: To correctly mount the Pet Alley Mask, the lens
must be removed from the front cover and
rotated 180
o
.
7. Replace front cover.
Note: When mounting on the ceiling, align the unit to
maximize the oblong detection pattern for the room.
Capture zone
at 8' (2.4m) mounting height
8. After walk testing, the LED cover can be slid up to cover
the LED.
Note: Unit should be walktested monthly to ensure continual
20' (6.12m)
WIDE
ANGLE
Align notch
with dimple
Inside of
Front Cover
Align notch
with rib
PET
ALLEY
ROTATE LENS
180
o
Rotate
Lens 180°
Inside of
Front Cover
Align notch
with dimple
For false-alarm-free operation, a PIR should not “see"
sources of heat or cold.
15'
(4.59m)
ZONE PATTERNS
With "Vertical Barrier" MaskWall Mount–No Mask
With "Pet Alley" Mask
Strip back the outer jacket on your wiring cable. This will
allow wires to flex in the case. Use cable strain relief built
into back cover to prevent stressing wires at their connection.
With "Single Spot" Mask
Wiring
NC COM TAMP TAMP
+
6255 Model
POWER-IN
7 to 16 VDC
NC COM T/NO TAMP
+
6257 Model
POWER-IN
7 to 16 VDC
1 Zone
2 Beams
29 Zones
58 Beams
7 Zones
14 Beams
7 Zones
14 Beams
With "Wide Angle" Mask
Side View
18 Zones
36 Beams
Side View
29 Zones
58 Beams
Ceiling Mount–No Mask
Capture
Zone
25' diameter (7.5m)
coverage pattern
8' (2.4m)
Note: Intruder must enter capture zone in order to be detected. False alarm sources,
such as heaters, should be kept out of the coverage pattern.
15' (4.59m) X 20' (6.12m)
capture zone
Note: The unit should be connected to a UL listed power
supply, capable of providing four hours of standby power.
Side View
30'
9.14m
40'
12.19m
38.4°
0'
7'
2.13m
0'
10'
3.04m
20'
6.09m
30'
9.14m
40'
12.19m
+54°
+38.4°
+18°
54°
20°
0°
54°
38.4°
20°
90°
0'
30'
(9.14m)
40'
(12.19m)
30'
9.14m
20'
6.09m
10'
3.04m
40'
12.19m
7'
2.13m
0'
10°
40'
12.19m
0'
40'
12.19m
0'
7'
2.13m
7°
Top View
10'
3.04m
30'
9.14m
20'
6.09m
Top View
5.9°
Top View
0'
10°
40'
12.19m
0'
40'
12.19m
10'
3.04m
20'
6.09m
30'
9.14m
7'
2.13m
Top View
Side View
Note: Lens must be
inverted for pet alley
90°
30'
9.14m
40'
12.19m
3'
.91m
40'
12.19m
0'
Side View
0'
10'
3.04m
20'
6.09m
30'
9.14m
Top View
PART LOOP ELECTRICAL LISTING
NUMBER TYPE CONFIGURATION
6255 Normally Closed N.C. UL
6257 Normally Closed or Open SPDT (N.C. and N.O.) UL
SURESHOT SPECIFICATIONS
6255 6257
ELECTRICAL
Voltage ................. 10 to 16 VDC ................ 7 to 16 VDC
Current ................. 14mA typical, ................ 8mA typical,
20mA max. 10mA max
Max. relay rating...16VDC, 50 mA ..............16VDC, 50 mA
Alarm output ...... Fail safe contacts ..........Fail safe contacts
w/10 ohms in series
Form A, ........................ Form C,
Normally Closed (NC)... Normally Closed and
Open (SPDT)
Alarm duration ..... 2 to 5 seconds ............. 2 to 5 seconds
Cover tamper ..... Normally Closed, ......... Normally Closed,
contacts rating: 50 mA, 12VDC.. rating: 50 mA, 12VDC
ENVIRONMENTAL
Operating Temp. ....0°F to 120°F ................ 0°F to 120°F
(-17°C to +50°C).......... (-17°C to +50°C)
Humidity ................ 10% to 90% ................. 10% to 90%
noncondensing ............ noncondensing
RFI immunity.....greater than 20V/m ...... greater than 10V/m
from 0 to 1000MHz .......from 0 to 1000MHz
Static immunity............ 20KV .......................... 2.5KV
Lightning immunity ..... 2.4KV,.......................... 2.5KV,
1.2 joules max energy....2 joules max energy
impulse, impulse,
100 µsec duration .....1msec rise/50 msec
in field wiring decay
1.20"
(3.05 cm)
Side View
Front View
2.25”
(5.72 cm)
3.75”
(9.52 cm)
P-3172
14377 Rev A
12345 SW Leveton Dr.
Tualatin, OR 97062
Tel.: 503.692.4052 Fax: 503.691.7566
U.S. & Canada: 800.547.2556
Technical Service: 800.648.7424
FaxBack: 800.483.2495
CORPORATE HEADQUARTERS
Sentrol reserves the right
to change specifications
without notice.
©1999 Sentrol
SENTROL
FEATURES
Pulse Count .........................Bi-directional, 1 zone (2 pulses)
with Motion Verification
Capture Zone (at 70˚ F)
Wide Angle (90˚) .......................30' (9.14m) x 30' (9.14m)
Single Spot ...................................... 40' (12.19m) range
Vertical Barrier ................................... 40' (12.19m) range
Pet Alley (90˚) ...................................... 30' (9.14m) range
360°Ceiling ......... 15' x 20' (4.57m x 6.10m) at 8' (2.44m)
mounting height
........16' x 30' (4.88m x 9.14m) at 12' (3.65m)
mounting height
...... Ceiling mounting height up to 12'(3.65m)
Mounting ............................................ Wall, corner, or ceiling
LED indicator ..........................................................Walktest
Size............................................................. 2.25"(5.72cm)W
3.75" (9.52cm)H
1.20" (3.05cm)D
Color ................................................................. White/White
3.75"
(9.52cm)
2.25"
(5.72cm)
Front View
1.20"
(3.05cm)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Interlogix 6250 Series Installation guide

Category
Motion detectors
Type
Installation guide

Interlogix 6250 Series is a versatile PIR motion detector that can be tailored to fit your specific security needs with a range of specialized masking plates to avoid false alarms. It boasts multiple detection patterns including wide angle, single spot, vertical barrier and pet alley, making it suitable for various applications. With a 30' x 30' capture zone, it can effectively cover large areas. Installation is simple with the included masking kit and adjustable LED indicator for easy walk testing.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI