Optex LX-402 is a passive infrared detector that detects moving objects by sensing temperature differences. It has a wide detection area of 120° and a long range of 40ft, making it suitable for use in both indoor and outdoor locations. The LX-402 features both multi-level and pet alley area detection patterns, allowing you to customize the detection area to your specific needs. Additionally, the adjustable sensitivity settings and day/night mode ensure optimal performance in all lighting conditions.

Optex LX-402 is a passive infrared detector that detects moving objects by sensing temperature differences. It has a wide detection area of 120° and a long range of 40ft, making it suitable for use in both indoor and outdoor locations. The LX-402 features both multi-level and pet alley area detection patterns, allowing you to customize the detection area to your specific needs. Additionally, the adjustable sensitivity settings and day/night mode ensure optimal performance in all lighting conditions.

A. TOP VIEW
B. SIDE VIEW
1.Multi-Level Area
A. TOP VIEW
B. SIDE VIEW
1.Multi-Level Area
2.Pet Alley Area
LX-402
LX-802N
2.DETECTION AREA PATTERNS
This product detects temperature differences between the moving object and the
background temperature in the detection area. So, if the object dose not move,
the detector can not detect it, and changing of the temperature differences may
affect the detector's detection range.
Additionally, since this product has directional characteristic it is difficult to detect
the target that is approaching the detector.
2.Pet Alley Area
FEATURES
FUNCTION
·LX-402 :40ft.(12m) 120° Wide Angle
·LX-802N:80ft.(24m) Long Range
·Selectable Detection Area Patterns
·Day/Night Mode
·Waterproof (IP Rating:IP54)
OPTION
·Ceiling Mount Bracket : CA-2C
·Multi-Angle Wall Mount Bracket :CA-1W
Adjust ±45° (Horizontally)
Adjust 0 - 20° (Vertically downwards)
·Selectable Pluse Count ( TEST or 2 )
·Selectable Sensitivity ( H , M or L )
·Form• C Relay Output
·Tamper Switch
LX-402,LX-802N
OUTDOOR PASSIVE INFRARED DETECTOR
120°wide Long Range
No.59-0961-1 010611
1 YEAR WARRANTY
Safety-Related Precautions
This icon indicates actions to be avoid. Details of the actions to be
avoided are written beside or near icon.
·Before installation,•• make sure to read this instruction manual carefully for safe and effective propduct operation.
·After reading this installation instructions, make sure to keep it in a conveninet place for future use.
This icon denotes a situation involving the risk of serious
injury or damage to property if the warning given is ignored.
Caution
This icon denotes a situation involving the risk of serious
injury or even death, if the warning given is ignored.
Warning
This icon indicates instructions that should be strictly followed.
Maximum mounting height is
8.3ft.(2.5m).
Mount the detector directly to a
wall or ceiling with the optional
bracket(model CA-1W or CA-2C).
Avoid moving objects in the
detection area (i.e.swaying
trees, bushes, etc.).
Aim the detector at wall or the ground,
to aviod unwanted detection.
When using the pet alley area,
the mounting height should be
between 4-5ft.(1.2-1.5m).
1.INSTALLATION HINTS
Avoid vapor or high humidity
that can cause condensation.
Avoid looking directly at air
conditioning or heating vents.
4-5 ft.
(1.2-1.5m)
8.3 ft. (2.5m) max
Never use this product for any application expect purpose for••
detecting moving object such as human or car. In addition, never
use for any activation for a shutter or other. It may cause hazards.
Clean and inspect the device periodically for safe operation.
If any defect is detected, ask your local shop to repair the device.
Warning
To avoid the risk of electric shock, never touch the main
body of the product with wet hands (Also, if the product is
wet after rain, do not touch it).
Caution
Never connect the terminal with higher power supply or current
draw over the specification. It increases the risk of fire or damage
to the product.
Never attempt to disassemble or modify the product, which
increases the risk of fire or damage of the product.
Avoid applying water directly from brackets, houses, or otherwise
splashing water directly onto the product. It increases the risk of
damaging the product.
alarm shop
3.DESCRIPTION AND OPERATION
4.INSTALLATION PROCEDURE
5.OPTIONAL BRACKETS
LED Indicater
Lens
cover screw
Day/Night Mode Adjustment
Inner Cover
Pulse Count Switch
Mount Pitch
3.28 Inches (83.5 mm)
Sensitivity Switch
Terminals
(Do not touch)
Sensor
Knockout
Multi-Level/Pet Alley
Adjustment Screw
Installation on wall
Installation on ceiling
1 3 NOTE ! 5 6 82
Loosen cover screw
and remove cover.
Pull wire throgh the
back of the detector.
If you have prob-
lems of wiring
through the back of
the detector, re-
move adjustment
screw and remove
the PCB from the
base.(see illus.)
Connect wires to
terminals, as shown.
Set the Day/Night
mode adjustment
to the “24HR” sett-
ing(DAY).
Set Pulse Count
to “TEST”mode.
Adjust sensitivity
setting (see sec-
tion 6-2 and 3).
Replace the cover
and supply power
to unit.
After the warmup
period is complete
(approx. 60 sec.) ,
conduct Walk Test.
The LED Indicator
lights when the
unit detects mov-
ing object.
Set the Day/Night mode
adjustment to the
NORMAL position(·).
( If night only operaton
is required , see sec-
tion 6-1)
Set Pulse Count to the
“2” position. ( see sec-
tion 6-1 and 2).
After wiring , pack the
provided sponge into
the opening between
each wires and the
knockout hole.
Select HIGH,
MEDIUM or
LOW
sensitivity(H,M,L).
Fasten cover with
the cover screw.
(see section 6-3)
Note ! Maximum mounting height is 8.3 ft (2.5m)
1. Ceiling Mount Bracket “CA-2C”
Adjust Horizontally : ±45° Adjust Vertically : 0° to 20° downward
2. Multi-Angle Wall Mount Bracket “CA-1W”
Adjust Horizontally : ±45° Adjust Vertically : 0° to 20° downward
4
7 After conduct-
ing Walk Test.
Mirror
Photocell
Rubber packing
AWG18
(0.83 mm
2
)
2700ft
(820m)
AWG20
(0.52 mm
2
)
1700ft
(510m)
AWG22
(0.33 mm
2
)
1070ft
(320m)
wires size
inches(mm) inches(mm)
Selectable 3 position
( H, M, L).
Adjust Day/Night Mode according
to desired DAY/NIGHT
operating periods.
If angle adjustment is required, use the
optional “CA-1W” mounting bracket
Use optional ceiling mount bracket ”CA-2C”.
Power supply wires
should not exceed
the following
lengths.
LED lights
during detection.
Loosen screw and select.
For Muli-level : Lower position”M”
For Pet Alley : Upper position”P”
Standard”2”pluse or
“TEST” mode.
Cover
21
Install the bracket
“CA-2C” on ceiling
and pull wire.
Attach the LX-402/
802N to the bracket
and pull wire.
alarm shop
6.SETTING AND ADJUSTMENT
1. Day/ Night Mode
Adjust the Day/Night Mode switch of the detector according to
the brightness of the surrounding area.
: To have the standard detector function
only during evening/night time, set the
dial to the reference position ( · ).
: To have the detector begin to function
while the surrounding area is lighter, turn
the dial gradually to the DAY side.
: To have the detector function only after it
has become dark, turn the dial gradually
to the NIGHT side.
: To have the detector function at all time,
or to perform a walk test, set the dial to
the DAY position.
2. Pulse Count Swich
“2” mode
: Select “2” for normal applications.
(STANDARD Position)
“TEST” mode
: Select “TEST” mode when conducting
WALK TEST , or for use in extremely
stable environments.
3. Sensitivity Switch
: Use “M” position for normal applications.
(STANDARD Position)
: Use “H” Position when you need high sensitivity.
(ex.Pet Alley Area)
: Use “L” position in areas that may be unstable.
7.DETECTION• AREA ADJUSTMENT
Changing vertical detection area
1.Multi-Level Area
Use this area for
normal applications.
2.Pet Alley Area
Provide a horizontal
detection pattern with
no declination of zones,
allowing pets to move
through the area.
Unit is pre-set at “Multi-Level” setting.
Selecting Pet Alley Pattern
Carefully loosen the
adjustment screw.
Slide the cover down
and fasten the screw
at the “P” position.
Flip the Mirror to the
upper position.
Eliminating unwanted detection zones
(LX-402 only)
Unwanted detection zones can be eliminated by simply masking
the lens with the provided masking strip, as follows:
Remove cover and apply strip to the
inside of lens on the zone to be
eliminated.(see illus.)
NOTE ! Pet Alley Area will not function if two changes are not
performed.
Unit is pre-set at “M” position.
NOTE ! Sensitivity setting must be one step higher position
when pet alley area is selected.
NORMAL Position
Unit is pre-set at “2” position.
Unit is pre-set at “NORMAL” position.
Example :
ZONE “a” can be eliminated by masking the lens at
area “a” (see illus.).
1.
2.
alarm shop
NOTE
This unit is designed to detect moving object and activate an alarm control
panel.Being only part of a complete alarm system,we cannot accept
responsibility for any damages or other consequences resulting from an
intrusion.
This Product conforms to the EMC Directive.89/336 EEC.
This product is NOT a human detector of security purpose.
We recommend our other detectors of security purpose,if you would like
to use detector for security purpose.
inches(mm)
LX-402 LX-802N
8.TROUBLE SHOOTING
9.SPECIFICATIONS 10.DIMENSIONS
PROBLEM PROBABLE CAUSE REMEDY
Improper power supply voltage. (disconnection, low
voltage)
Confirm the power supply is under specification.
Wrong polarity Switch positive and negative at terminal.
The detector is in warm up period. Wait for.(approx. 60 sec.)
See section 6-1.
Confirm the adjustment knob.
Incorrect detection area. See section 2.
Moving object within area. (curtain, wall hanging, etc.) Remove the object from the detection area.
Improper power supply voltage. Confirm the power supply is under specification.
LED lights up even though no one The unit is detecting presons, cars or other
is in detection area. objects beyond the set area.
Temperature of object within area is changing rapidly
(heater, air conditioning, etc.)
Remove the heat sources from the detection area.
Check load of output.
The unit needs repair or replacement.
Faulty wiring. Wire correctly.
The LED lights up, but there is no Alarm output connects to other devices as follows.
relay output when NC output is used when NC output is used
:connect in parallel. :connect in series.
when NO output is used when NO output is used
:connect in series. :connect in parallel.
Check the detection area.
Relay contact is stuck or damaged due to overloading.
LED does not light up.
The Day/Nigth Mode Adjustment knob setting is
inappropriate.
LX-402 LX-802N
40ft×50ft(12m×15) 80ft×6.6ft(24m×2)
120°wide Long range
Multi-Level Area 40 zones 12 zones
Pet Alley Area 18 zones 4 zones
Multi-Level Area
Pet Alley Area
6.0oz (170g) 6.8oz (190g)
Approx. 60 sec.
10.8-13.2VDC
Opens when cover removed.
2 (20±5 sec.) or TEST(1 pulse)
Approx. 10 to 100,000 lux
Mounting
IP54
25 mA max
Wall (Indoor/Outdoor)
-F - +122°F(-20
- +50
)
95% max
Current draw
IP Rating
Passive Infrared
8.3ft (2.5m) max
4-5ft (1.2-1.5m)
1-3.3ft/sec. (0.3-1.0m/sec.)
Selectable 3 position (H,M,L)
LED lights during detection
2±1 sec.(Delay timer)
NC.NO.28V DC 0.2A max
Accessory
Masking strips (LX-402 only),Mounting screw,Sponge
Specifications may be changed without prior notice for improvements.
Operating temperature
Environment humidity
Weight
Day/Night Mode adjustment
Warm up period
Power input
Detection speed
Sensitivity adjustment
LED indicator
Alarm period
Alarm output
Pulse count
Tamper switch
Model
Detection method
Coverage
Mounting height
Detection area
alarm shop
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Optex LX-402 Installation guide

Type
Installation guide

Optex LX-402 is a passive infrared detector that detects moving objects by sensing temperature differences. It has a wide detection area of 120° and a long range of 40ft, making it suitable for use in both indoor and outdoor locations. The LX-402 features both multi-level and pet alley area detection patterns, allowing you to customize the detection area to your specific needs. Additionally, the adjustable sensitivity settings and day/night mode ensure optimal performance in all lighting conditions.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI