Quest Engineering DEH 3000R is a digital control device that offers precise monitoring and adjustment of relative humidity levels, fan operation, and ventilation in your space. With a sleek design and user-friendly interface, it seamlessly integrates with your existing HVAC system, providing you with the convenience of controlling multiple aspects of your indoor environment. The DEH 3000R features a large, backlit LCD display for easy viewing and intuitive navigation, allowing you to quickly access and modify settings as needed.

Quest Engineering DEH 3000R is a digital control device that offers precise monitoring and adjustment of relative humidity levels, fan operation, and ventilation in your space. With a sleek design and user-friendly interface, it seamlessly integrates with your existing HVAC system, providing you with the convenience of controlling multiple aspects of your indoor environment. The DEH 3000R features a large, backlit LCD display for easy viewing and intuitive navigation, allowing you to quickly access and modify settings as needed.

Installation, Operation and Maintenance Instructions
– Read and Save These Instructions –
This manual is provided to acquaint you with
the Quest DEH 3000R so that installation,
operation, and maintenance can proceed
successfully. Ultimate satisfaction depends
on the quality of installation and a thorough
understanding of this equipment.
Quest DRY 150
Installation, Operation and Maintenance Instructions
4201 Lien Rd
Madison, WI 53704 1-800-533-7533
www.QuestProtect.com sales@thermastor.com
– Read and Save These Instructions –
Specications subject to change without notice.
TS-721
12/12
1
Quest DEH 3000R Digital Control
Quest DEH 3000R Digital Control:
• Digitalcontrolofrelativehumidity
(DigitalSet-Point)
• Fan/Filteroperation
• Programmableventilationtimer
• Sleekdesign
• Large,easy-to-readbacklitLCDdisplay
• Hightemperaturecut-out
• Dryoutcycletimer
• Autoreboot
quest
quest
quest
quest 1-800-533-7533
2
www.QuestProtect.com
sales@questprotect.com
Quest DEH 3000R Installation, Operation and Maintenance Instructions
Table of Contents
1.Specications.................................................................. 3
2.Installation...................................................................... 3
2.1 ControlPanelInstallInstructions............................. 3
2.2 RemoteSensorInstallInstructions........................... 4
2.3 RemoteSensorUsage............................................. 4
2.4 RemoteSensorWiringInstructions.......................... 4
2.5 ControlPanelWiringInstructions............................ 5
2.6 AuxiliaryRelayOperation....................................... 6
2.7 Dehumidierlock-OFForlock-ON........................ 7
2.8 Testing.................................................................... 8
3.Operation........................................................................ 9
3.1 Display................................................................... 9
3.2 Setting.................................................................. 10
3.3 PersonalSettingsReferenceList............................ 10
3.4 On/OffandDisplaySettings.................................. 10
3.5 SettingClock........................................................ 10
3.6 AdjustingtheRelativeHumidity............................ 11
3.7 FanSettingandOperation.................................... 11
3.8 DamperOperationandSetting(Ventilation)......... 12
3.9 TemperatureCutoutProgramming........................ 14
Warranty............................................................... 15
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
3
www.QuestProtect.com
sales@questprotect.com
quest
quest
24VACYellowWire 24VACRedWire
Damper
WhiteWire
(Optional.See
warningbelow)
Dehumidier
BlueWire
Fan
GreenWire
ON-Detect
Common
OFF-Detect
NormallyOpen
Common
NormallyClosed
Optional
Use
Optional
Use
1. Specications
Part#(P/N)  4028531
Model:  QuestDEH3000RDigitalControl
Electrical:  24VAC
MaxCurrent–
DMP,COMP,FAN:  1Ampeach
HumidityOperatingRange:  10–95%
HumidityControlRange:  35–70%
HumidityAccuracy: 
±
5%
Output:  3Amps24VAC
Aux.RelayCapacity  5Amps
TempRange/  30°-90°F,2%
Accuracy
Size  4.95"Lx1.06"Wx4.19"H
FOR HVAC INSTALLER ONLY:
2. Installation
InstalltheQuestDEH3000Rremotesensorinacentralarea
ofthestructurewhereitwillsensetherelativehumidityofthe
structureaccurately.Donotinstalltheremotesensorwhere
itmaynotaccuratelysensetherelativehumiditysuchasnear
HVACsupplyregisters,nearexteriordoorsandwindows,ornear
apoolorspa.Installinaccordancewithallapplicablecodesand
standards.
2.1 Control Panel Install Instruc-
tions
1. Separatethefrontpanelfromtheback
panelbydepressingthemiddlesections
ofthetopandbottomofthefrontpanel.
2. Locatethewiringaccessholeinthe
wallorotheratmountingsurface.
Placethebackpanelintopositionand
drilltheappropriatemountingholes.
3. Insertthescrewsandtighten.Levelas
necessary.
4. Maketheelectricalconnectionstothe
terminalsonthebackpanelasshownin
theapplicablewiringdiagram(seeSections2.2-2.4).
5. Testtheinstallation(seeSection2.5).
quest
quest 1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
4
www.QuestProtect.com
sales@questprotect.com
2.2 Remote Sensor Install Instructions
This section is applicable only to customers who have purchased a remote
sensor package. The standard DEH 3000 controller does not offer remote
functionality.
2.3 Remote Sensor Usage
IMPORTANT!
•Theuseofspraypaintonthesensorhousingmaydamagethesensorandisnotcoveredbytheproduct
warranty.
Theremotesensingoptionisusedwhenaninstallationrequiresmountingthehumidityandtemperaturesensor
outoftheconditionedspaceorwhenitisdesiredtospecicallymonitorandcontroltheconditionsataparticular
locationinalargerconditionedspace.
Boththeneedforandlocationoftheremotesensorshouldbedeterminedbyaheating/coolingprofessional.
2.4 Remote Sensor Wiring Instructions
1.Routingsignalwires:
Youwillberequiredtosupplyandroute24gauge,4conductorsolidwire(2-linetelephonewire)betweenthe
DEH3000Rcontrollerandtheremotesensorlocation.•Donotrunwireslongerthan100ft.
•Theuseof24gaugewireisoptimal.Thinnergaugewiremaylimitsensordistance.Thickergaugeswillnotwork
withspliceconnectorsprovided.
•Avoidroutingparalleltohighvoltagewiring.
•Maintainadistanceof2ft.ormorefromhighvoltagelines.
2.Sensorconnection:
Thesensorcanbemountedtoawallorceilingsurface.Idealsensorlocationis5ft.abovetheoor.Wires
shouldexitthrougha½”diameterholeinthemountingsurfaceatthemountinglocation.Usetheprovidedsplice
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
5
www.QuestProtect.com
sales@questprotect.com
quest
quest
connectorstoconnectthe4wiresfromtheremotesensortotheuser-suppliedinterconnectwire.Besuretokeep
propercolorsattachedtoeachother.
3.Sensormounting:
Youwillneedtwoscrewstomountthesensor.Usethetwoslottedholestomountthebaseofthesensortothe
wallandthensnapthecoverintoplace.
4.Controllerconnection:
Usetheprovidedspliceconnectorstoconnectthe4wiresfromtheDEH3000Rtotheuser-suppliedinterconnect
wire.Besuretokeepthepropercolorsattachedtoeachother.
Continuewiththeinstallationasdescribedintherestofthismanual.
2.5 Control Panel Wiring Instructions
WARNING! DO NOT ALLOW THE YELLOW WIRE FROM THE QUEST DEHUMIDIFIER
TO CONTACT THE RED OR WHITE WIRES FROM THE QUEST DEHUMIDIFIER, DAMAGE TO THE 24-VOLT
TRANSFORMER WILL RESULT.
WARNING! THE QUEST DEH 3000R DIGITAL CONTROL OPERATES ON A LOW
VOLTAGE CIRCUIT (24 VAC) AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE
CIRCUIT.
WARNING! UNPLUG THE QUEST DEHUMIDIFIER BEFORE WIRING THE DEH 3000R.
Theinstallermustsupplyalleldwiring,includingthewiringbetweentheQUESTdehumidierand
theQuestDEH3000R.SomeofthecontrolwiresleavingtheQUESTdehumidiermaynotbeused
insomecontrolsituationsandshouldbeleftdisconnectedwithwirenutstapedontothestripped
ends.
BesuretoconsulttheelectricalschematicinthismanualortheinternalelectricalboxoftheQuest
dehumidierbeforemakinganycontrolconnections.
WARNING! ONLY CONNECT THE WHITE WIRE TO THE CONTROL IF IT IS WIRED IN A
CIRCUIT THROUGH AN ELECTRIC DAMPER, OTHERWISE TRANSFORMER DAMAGE MAY RESULT.
quest
quest 1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
6
www.QuestProtect.com
sales@questprotect.com
TheWhitewirecontrolstheoptionalmotorizeddamperthatcanbeinstalledintoafreshair
duct.Thisdamperprovidestheabilitytocontrolfreshairventilationusingtheventilation
timerfunctionoftheQuestDEH3000Randtheterminal
labeled“DMP” (SeeSection3.8).Leavethe“DMP”
terminalunusedifamotorizeddamperisnotused,and
capofftheWhitewirefromtheQuestdehumidier.
Standard wire colors for thermostats are as follows:
Description Color Terminal code
24VAC Red R
CallforHeat White WorW1
ForceFanOn Green G
Compressor
CallforCooling Yellow YorY1
2.6 Auxiliary Relay Operation
Itmaybedesirabletocoordinatefanoperationofthecentral
heating/coolingsystemwithdehumidierfanoperation.The
QuestDEH3000Rcontainsarelaythatprovidesthisability.
TherelayterminalslabeledNC,COMandNOoperate
accordingtothefollowingchart:
FAN COM to NO COM to NC
ON CONNECTED OPEN
OFF OPEN CONNECTED
Commonuses(assumingstandardthermostatwiringcolorsas
noted):
NO
COM
NC
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
7
www.QuestProtect.com
sales@questprotect.com
quest
quest
Lock-out the A/C during dehumidier fan operation
ThiswillturnofftheA/Cwheneverthedehumidierfanruns.
1.WiretheYellowthermostatterminaltotheNCterminalontheQuestDEH3000R.Theinstaller
mustsupplythewiringbetweentheQuestdehumidierandthecontrolpanel.Besuretosafelyroutethe
controlwirestopreventdamageduringinstallation.Be
carefulnottocrossthewireswhenconnectingtheQuest
dehumidierandtheremotecontrolpanelordamageto
thetransformermayresult.
2.RuntheYellowwirefromtheA/CunittotheCOM
terminalontheQuestDEH3000R.
Energize the A/C central fan during dehumidier fan
operation
ToautomaticallyruntheA/CFANwhenthedehumidier
fanruns.
1.AttachasecondGreenwiretotheGreenfanwire
terminalonthethermostat.
2.ConnectthenewGreenwiretotheCOMterminalonthe
QuestDEH3000R.
3.RunawirefromtheRedterminalonthethermostatto
theNO(NormallyOpen)terminalontheQuestDEH
3000R.
2.7 Dehumidier lock-OFF or lock-ON:
A/C sensor feature
Toautomaticallyactivateordeactivatethedehumidierwhentheairconditionerruns.
Activate dehumidication when the air-conditioner is running.
A voltmeter is required for the next steps to ensure the correct wiring from
the A/C transformer is used to set up the Lock-in dehumidier function.
1.ThecommonwirefromtheexistingA/Ctransformer(usuallyBlack)
mustbeattachedtothe“COM”sensorterminalbetween“ON-D”
and“OFF-D”ontheDEH3000R.
TIP: The common wire can be identied as the wire from the A/C
transformer that reads 0 volts between it and the Yellow air conditioning call
for cooling wire.The incorrect wire will give a 20 to 28 volt reading.
2.AnotherYellowwiremustbeaddedtothe
thermostatYellowterminalandruntothe“ON-D”
sensorterminalontheQuestDEH3000R.
A/C
Unit
Red
Green
Yellow
A/C
Unit
Red
Green
Yellow
A/C
Unit
Red
Green
Yellow
A/C
Unit
Red
Green
Yellow
ON-D
COM
OFF-D
TO A/C
TO A/C
quest
quest 1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
8
www.QuestProtect.com
sales@questprotect.com
Deactivate dehumidication when the air-conditioner is running.
Avoltmeterisrequiredforthenextstepstoensurethe
correctwiringfromtheA/Ctransformerisusedtosetup
theLock-outdehumidierfunction.
1. ThecommonwirefromtheexistingA/C
transformer(usuallyBlack)mustbeattachedto
the“COM”sensorterminalbetween“ON-D”
and“OFF-D”ontheDEH3000R.
TIP: The common wire can be identied as the wire
from the A/C transformer that reads 0 volts between
it and the Yellow air conditioning call for cooling wire.
The incorrect wire will give a 20 to 28 volt reading.
2.AnotherYellowwiremustbeaddedtothethermostatYellowterminalandruntothe“OFF-D”
sensorterminalontheDEH3000R.
2.8 Testing
Verifythewiringconnections.
WARNING! ONLY CONNECT THE WHITE WIRE TO THE CONTROL IF IT IS WIRED IN
A CIRCUIT THROUGH AN ELECTRIC DAMPER, OTHERWISE TRANSFORMER DAMAGE MAY RESULT.
Aftercheckingthewiring,thisshorttestwillconrmproperhook-up.
1. InstallfrontcoveroftheQuestDEH3000R;connectthetoprst,thenthebottom.
2.PlugintheQUESTdehumidier.TheQuestDEH3000Rshouldpowerup.
3.TurntheQuestDEH3000RONbypressingtheON/OFFbutton.
4.VerifydehumidicationoperationbyadjustingtheRHSETPOINTtobelowthe“%RH”
readingonthedisplay.UsethedownRHbutton.ConrmQuestfanandcompressor
operation.BothshouldbeONnow.
IncreasetheRHSETPOINTonthedisplaytowellabovethe“%RH”readingonthedisplay.Pressthe“RH”
uparrowtoincreasetheRHSETPOINT.
AfterrunningthedehumidiercompressortheQuestDEH3000Rappliesa10minuterestartlockoutonall
functions.Youwillhavetowaitfortherestartlockouttoexpire.
5.VerifyFAN-onlyoperation:
a.ChecktheVENTmodeonthedisplay,itwilleitherbeCLOSEDorOPEN.IfitisCLOSEDgoto
thenextstep.IfitisOPEN,pressandholdtheVENTkeyuntil“OPENashesonthedisplay,release
thekeyandthenpressitonemoretime.OPENwillchangetoCLOSED.Don’ttouchthekeysfor
severalsecondsuntilitstopsashing.
b.PressandholdtheFANbuttonuntilAUTObeginsashingonthedisplay,releaseit,andthenpressit
againtoswitchthefantotheONsetting.
c.ConrmthattheQUESTfanisON.QuestcompressormustbeOFF.Ventilationdamper(ifused)should
beCLOSED.
6.VerifyoptionalVENToperation(ifelectricdamperisinstalled):
a.PressandholdtheFANbuttonuntilONashesonthedisplay.
b.ReleasetheFANbutton,thenpressitagaintoswitchfanoperationtoAUTO.
TO A/C
TO A/C
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
9
www.QuestProtect.com
sales@questprotect.com
quest
quest
c.PressandholdtheVENTbuttonuntilCLOSEDashesonthedisplay.
d.ReleasetheVENTbutton,thenpressitagaintoswitchventmodetoOPEN.
e.ConrmthattheQuestfanisON.VentilationdamperisOPEN.QUESTcompressormustbeOFF.
f.PressandholdtheVENTbuttonuntiltheOPENashesonthedisplay.
g.ReleasetheVENTbutton,thenpressitagaintoswitchventmodetoCLOSED.
Troubleshooting:
Ifanyfunctionsarenotworkingproperly,checkthewiringandconnections.Avoltmetermaybeusedacross
terminalstoverifyvoltage.Ifthereisconcernaboutthedehumidiernotoperatingproperly,theleadsexitingthe
QUESTdehumidiermaybeconnectedaccordingtothefollowingchart:
Wire connections Operation
Yellow&Blue Fan&Compressor
Yellow&Green FanOnly
WARNING!DO NOT MAKE ANY OTHER CONNECTIONS OR TRANSFORMER DAMAGE
MAY RESULT.
7.VerifyanyadditionaloptionalcontroloperationssuchasfaninterlockorA/Clockout.
8.ProceedtotheOperationsection.
FOR INSTALLER & OWNER:
3. Operation
Onthedisplayscreen,asolidOinfrontofanyofthe3functions(SETPOINT,VENT,FAN)indicatesthefunction
isoperating.AashingOindicatesitisinawaitmodeandnotavailableatthemoment.NoOindicatesthe
functioniscurrentlyOFF.
SolidObefore Indicates
SETPOINT Dehumidieron
VENT Freshairventilationcycleinprogress
FAN Fanon
Waitmodeisafactory-programmedtimeperiodmeanttopreventshortcycles.Thisextendsthelifeofthe
dehumidier.WhenaashingOisencountered,theunitisinwaitmodeandIT COULD BE UP TO 10
MINUTES BEFORE OPERATION RESUMES.
3.1 Display
•Wheneverthereispowertothecontrol,itwilldisplaythetime,theday,%relativehumidity,andtemperature.
•WhenthecontrolisactuallyswitchedON,the%RHsetpoint,fanstatus,runmode(programorhold),andfresh
airventilationstatusisdisplayed.
•Whenakeyispressedthedisplaywilllightforapproximately½aminute.
•TheTimeandDayisdisplayedatthetopofthescreen.
quest
quest 1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
10
www.QuestProtect.com
sales@questprotect.com
•RHandTemperaturearedisplayedinrealtime.
•AsolidObeforetheSETPOINT,VENT,ORFANindicatesthefunctionis
operating.
•AashingObeforetheSETPOINT,VENT,ORFANindicatestheunitis
inwaitmode.
3.2 Setting
Duringtheset-upprocess,ifyoumakeamistake,simplycontinue.Youcanalwaysgobacktoadjustthesettings.
Ifyouleavethecontrolaloneanddon’ttouchanybuttonsfor10seconds,thecontrolwillrememberany
changesmadeandreturntothenormaldisplayscreen,allowingyoutoproceedtothenextstep.
3.3 Personal Settings reference list
Please record your settings here.
Function Factory setting My Setting
SETPOINT(%RH) 50%
VENT Closed
FAN Auto
TEMPCUTOUT 99°
3.4 On/Off and display items
Pressthe“ON/OFFbuttontoturnthesystemONorOFF.
WhenthesystemisON,thesetpoint,fanstatus,operationmode(RUNor
HOLD),andfreshairventstatusisdisplayed.
WhenthesystemisOFF,thecontrolwilldisplaythetime,day,%RH,and
temperature.
Whentheunitisshipped,itisinmanual(hold)mode.
3.5 Setting Clock Time
1.PressandholdtheCLOCKbutton.Thehourdisplaywillash.Release
thebutton.
2.Usetheup/downRHbuttonstochangethevalue.
3.PresstheCLOCKbuttonagainandtheminutedisplaywillash.Use
theRH”buttonstochangethevalue.
4.PresstheCLOCKbuttonagainandAMorPMwillash.UsetheRHbuttonstochangethevalue.
5.Pressthe“CLOCK”buttonagainandthedaydisplaywillash.Usethe“RH”buttonstochangethevalue.
6.Don’ttouchanybuttonsforseveralsecondsuntilthedisplaystopsashing,thiswillsaveyoursettings.Ifyou
needtochangeanythinggobacktostep#1.
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
11
www.QuestProtect.com
sales@questprotect.com
quest
quest
3.6 Adjusting the relative humidity “SETPOINT”
TheQuestDEH3000Rsensestheambientrelativehumidity(%RH)ofthespaceinwhichitislocated,itcomes
factorypresettohold50%relativehumidity.
TherelativehumiditySETPOINT(desiredRHtobemaintained)operates
thedehumidierfunctionoftheQuestdehumidier.Ithasnoeffectonthe
optionalVENT(freshairventilation)orFAN(airrecirculation)functionsifthey
arebeingused.
Operation
ThestandardrangethatthedehumidierholdsaroundyourSETPOINT”
is3%.Withasetpointof50%,thedehumidierwillrununtiltherelative
humidityreaches47%.Thedehumidierwillthenswitchoffuntiltherelative
humidityreaches53%.
Ifthesetpointishigherthantheambientrelativehumidity,thespacedoesnotneedtobedehumidiedsothe
dehumidierwillnotrun.
Example:Setpoint:50%RH
Currentcondition:45%RH–Thedehumidierwillbeoff(noOindicatorwillbedisplayed).
Ifyoursetpointisbelowtheambientcondition,thedehumidierwillbeonandOwilldisplay.
Example:Setpoint:50%RH
Currentcondition:55%RH–Thedehumidierwillbeon(O”displayed).
3.7 Fan Setting and Operation
UsetheFANbuttontochangethefanoperation.Thereare2choicesforfanoperation:ONorAUTO.The
factorypresetisAUTO.
ON–ThefanintheQuestdehumidierwillruncontinuously.Thisdoesnotaffecteitherthedehumidication
orventilationfunctionsofthesystem.Thesystemmayormaynotbeventilatingordehumidifyingwhilethefanis
running.Thissettingiscommonlyusedformaximumairltrationand/orairrecirculation.
AUTO–IndicatesthefanwillrunwhentheQuestDEH3000Rcallsfordehumidicationorventilation.Ifthe
controlhasnotcalledfordehumidicationfor3hours,thecontrolwillautomaticallyrunthedehumidierfanfor
10minutes.
Afteradehumidicationcycle,thefanautomaticallyshutsofffor10minutes.Thispauseallowsthewatertodrain
fromthedehumidier.
AsolidOindicatesthefanisoperating.AashingOindicatesthefanisinawaitmode.NoOindicatesthe
fanisOFF.
Tosettheoperation:
1.PressandholdtheFANbutton.Thecurrentfansettingwillbegintoash
onthedisplay.Releasethebutton.
2.PresstheFAN”buttontotogglebetweentheONandAUTOmodes.
WiththefanintheAUTO”mode,thefanwilloperateonlywhenneeded
byotherfunctionsofthesystem.ThefanwillremainOFFunlessthesystem
isdehumidifyingorventilating.Thefanalwaysrunsduringdehumidication
andventilationandthefanOiconwillbelit.Tocompletelyturnthe
systemOFF,usetheON/OFFbuttonasdescribedearlier.
quest
quest 1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
12
www.QuestProtect.com
sales@questprotect.com
3.8 Damper Operation and Ventilation,
Manual (Hold) Mode
TheVENTsettingcontrolstheventilationfunctionofthesystem.Ithasnocontroloverthedehumidication
function.Inordertoprovideventilation,themotorizeddampermustbeopenandthefanmustberunning.The
controllertakescareofthesetwofunctionsautomaticallysothatwheneverthedamperisopen,thefanisrunning.
TheventilationindicatorOwillbedisplayedwhenevertheunitisventilating.ThefanoperationindicatorO”
willalsobelit.
Therearethreedamperoperationmodes:
1.OPEN–holdmode:Thedamperwillbeopenandthedehumidierfanwillbecontinuouslyoperatingto
introducefreshairintothespace.Usethismodeforcontinuousfreshairventilation.Thefanisalwaysonwhen
thedamperisopen.
2.CLOSED–holdmode:Thedamperwillneveropen,andthedehumidierwillnotventilate.Thefanwillstill
operatenormallyforrecirculationanddehumidication.
3.PROGRAMMEDmode:TheQuestDEH3000Rwilloperatethemotorizeddamperandthedehumidierfan
accordingtotheprogrammedventilationschedule(Section3.9).
ThefactorypresetfortheVENTsettingisCLOSED.
Toset“OPEN”–holdor“CLOSED”–holdventilationoperation:
1.PresstheVENTbutton.Thecurrentsettingwillbegintoashonthedisplay.Releasethebutton.
2.Pressthe“VENTbuttonagaintoswitchbetween“OPEN”andCLOSED.
3.Leavethecontrolalonefor10secondsandyoursettingswillbesaved.
Damper Operation and Ventilation, Programmed Ventilation
Thisexampleshowsthesysteminprogrammode(denotedbytheschedule15minuteson,5minutesoffandthe
wordRUNinthelowerrightcornerofthedisplay).
TheQuestDEH3000Rwilloperatefreshairventilationaccordingtoyour
ventilationprogram.Thecontrolneedstobeprogrammedtoturnthe
ventilationfunctionONandOFFatthedesiredintervals.Thisisdoneby
programmingtheventilationtimer.
Therearetwoprogramsavailableforventilation:
1.MondaythroughSunday
2.MondaythroughFriday&Saturday/Sunday
Eachblockofdayshasamorningscheduleandanightschedule.Morning
istherst12hoursofthedayandnightisthesecond12hours.
Eachschedulehas:
•ASTARTtimewhentheventilationschedulebegins,
•AnOPEN FOR”durationfortheamountoftimethedamperstaysopenin5minuteintervals,from0to60,
•AndCLOSED FORdurationwhichclosesthedamperforaspeciedtimein5minuteintervalsfrom0to60.
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
13
www.QuestProtect.com
sales@questprotect.com
quest
quest
Setting the Ventilation Program:
1.Pressthe“PROGRAM ENTERbuttonuntilthefollowingmenu
appears:
2.Usingtheup/down“RH”buttons,highlightPROGRAMandselect
itbypressingthePROGRAM ENTER”button.Thefollowingmenu
appears:
Youcanselectfrom:
MON-FRI”“SAT-SUNforseparateweekdayandweekendschedules,or
MON-SUNwhichgivesyouequalweekdayandweekendschedules.
3.UsingtheUp/DownRH”buttons,highlightandthenselectoneofthetwochoices.Theexamplegivenshows
howtoprogramseparateweekdayandweekendschedules.Thesamemethodisusedifyouchoosetheother
program.
Example:menuwhenyouselectMON-FRI”“SAT-SUN”:
1.Enterthestartingtimeforweekdaysusingtheup/downRH”buttonstochangethetime.
2.PressthePROGRAM ENTER”buttontoswitchtotheOPEN FORsetting.Usingtheup/down“RH”buttons,
changethedurationthatthedamperwillventilatefreshair.
3.PressthePROGRAMENTERbuttontoswitchtothe“CLOSEDFOR”setting.Usingtheup/downRH”
buttons,changethedurationthatthedamperwillremainclosedbetweenventilationcycles.
Fortheexamplegiven,startingat8:00AMinthemorning,thecontrolwillventilatefreshairfor15minutesthen
stopfor15minutes.Thisscheduleof15minutesopen,15minutesclosedwillcontinueuntilthestarttimeofthe
nightschedule.
Morningscheduleisavailableanytimefrom12:00AMuntil11:59AM.
Nightscheduleisavailableanytimefrom12:00PMuntil11:59PM.
4.Press“PROGRAMENTERagaintogototheMON-FRInightschedule.Repeatthestepslistedaboveforthis
andtheSAT-SUNdayandnightschedules.
quest
quest 1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
14
www.QuestProtect.com
sales@questprotect.com
Whenyouhavenishedprogrammingyourschedule(eitherthe7-dayversionortheweekday/weekendsplit
version),usethedown“RH”buttontohighlighttheEXIToptionandthenpressPROGRAM ENTER”toselectit.
RunningtheVentilationProgram
PressandholdthePROGRAM ENTER”buttonuntilthe“PROGRAMscreenappears.
UsethedownRHbuttontohighlightRUN PROGRAM:
ThenpressPROGRAMENTERtoselectit.Thedisplaywillappearasfollows:
3.9 Temperature Cutout Programming
Dehumidiersproduceheatwhendehumidifyinganddependinguponoutsideconditions,theventilation
functionmayalsointroducewarmair.Someconditionsmayintroduceenoughheattodrivetemperaturesup.
TheQuestDEH3000RtemperaturecutoutfeaturedisablesallQuestoperationsiftemperaturesreachthecutout
setpoint.
Inmostinstallationsthisfeaturewillnotneedtobeused(thecutoutisfactorysetto99°F).Ifalowertemperature
cutoutisdesired,programthesetpointbypressingandholdingthePROGRAMENTERbuttonuntilthe
PROGRAM”screenappears.Presstheup/down“RH”buttonsuntilTEMPCUTOUThighlighted.Thenpress
the“PROGRAMENTERbuttonagaintoselectit.NowusetheRHuporRHdownbuttonstoadjustthe
setpoint.PressPROGRAMENTERtoreturntothehomescreen.
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
15
www.QuestProtect.com
sales@questprotect.com
quest
quest
WARRANTOR:
Therma-StorLLC
4201LienRd
Madison,WI53704
Telephone:1-800-533-7533
WHO IS COVERED: Thiswarrantyextendsonlytotheoriginalresidentialend-useroftheQuest
DEH3000RDehumidier&VentilationSystemController,andmaynotbeassignedortransferred.
FIRST YEAR WARRANTY: Therma-StorLLCwarrantsthat,forone(1)yeartheQuestDEH3000R
Dehumidier&VentilationSystemControllerwilloperatefreefromanydefectsinmaterialsand
workmanship,orTherma-StorLLCwill,atitsoption,repairorreplacethedefectivepart(s),freeof
anycharge.
END-USER RESPONSIBILITIES:WarrantyservicemustbeperformedbyaServicerauthorizedby
Therma-StorLLC.Iftheend-userisunabletolocateorobtainwarrantyservicefromanauthorized
Servicer,heshouldcallTherma-StorLLCattheabovenumberandaskfortheTherma-StorLLC
ServiceDepartment,whichwillthenarrangeforcoveredwarrantyservice.Warrantyservicewillbe
performedduringnormalworkinghours.
TheEnd-usermustpresentproofofpurchase(lease)uponrequest,byuseofthewarrantycardor
otherreasonableandreliablemeans.Theend-userisresponsiblefornormalcare.Thiswarrantyonly
appliestoresidentialapplicationsanddoesnotcoveranydefect,malfunction,etc.resultingfrom
misuse,abuse,lackofnormalcare,corrosion,freezing,tampering,modication,unauthorizedor
improperrepairorinstallation,accident,actsofnatureoranyothercausebeyondTherma-StorLLC's
reasonablecontrol.
LIMITATIONS AND EXCLUSIONS:IfanyQuestDEH3000RDehumidier&VentilationSystem
Controllerpartisrepairedorreplaced,thenewpartshallbewarrantedforonlytheremainderofthe
originalwarrantyperiodapplicablethereto(butallwarrantyperiodswillbeextendedbytheperiod
oftime,ifany,thattheQuestDEH3000RDehumidier&VentilationSystemControllerisoutof
servicewhileawaitingcoveredwarrantyservice).
UPONTHEEXPIRATIONOFTHEWRITTENWARRANTYAPPLICABLETOTHEQuestDEH3000R
Dehumidier&VentilationSystemControllerORANYPARTTHEREOF,ALLOTHERWARRANTIES
IMPLIED BY LAW, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, SHALLALSO EXPIRE.  ALLWARRANTIES MADE BYTHERMA-STOR LLC ARE SET
FORTHHEREIN,ANDNOCLAIMMAYBEMADEAGAINSTTHERMA-STORLLCBASEDONANY
ORAL WARRANTY. IN NO EVENT SHALLTHERMA-STOR LLC, IN CONNECTION WITHTHE
SALE,INSTALLATION,USE,REPAIRORREPLACEMENTOFANYQuestDEH3000RDehumidier
&VentilationSystemControllerORPARTTHEREOFBELIABLEUNDERANYLEGALTHEORYFOR
ANYSPECIAL,INDIRECTORCONSEQUENTIALDAMAGESINCLUDINGWITHOUTLIMITATION
WATER DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST
PROFITS,DELAY,ORLOSSOFUSEORDAMAGETOANYREALORPERSONALPROPERTY.
Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,andsomedonotallow
theexclusionorlimitationofincidentalorconsequentialdamages,sooneorbothoftheselimitation
maynotapplytoyou.
LEGAL RIGHTS: Thiswarrantygivesyouspeciclegalrights,andyoumayalsohaveotherrights
whichvaryfromstatetostate.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

Quest Engineering DEH 3000R Installation, Operation And Maintenance Instructions

Category
Thermostats
Type
Installation, Operation And Maintenance Instructions

Quest Engineering DEH 3000R is a digital control device that offers precise monitoring and adjustment of relative humidity levels, fan operation, and ventilation in your space. With a sleek design and user-friendly interface, it seamlessly integrates with your existing HVAC system, providing you with the convenience of controlling multiple aspects of your indoor environment. The DEH 3000R features a large, backlit LCD display for easy viewing and intuitive navigation, allowing you to quickly access and modify settings as needed.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI