  • Hello! I've reviewed the Installation, Operation and Maintenance Instructions for the Quest DEH 3000R Dehumidifier Controller. This document outlines how to install, operate and maintain your device, explaining features such as digital humidity control, fan operation, ventilation timers, and temperature cut-outs. I am ready to answer your questions about its functionality and settings.
  • What is the humidity operating range of the Quest DEH 3000R?
    What is the humidity control range of the Quest DEH 3000R?
    What is the temperature range of the Quest DEH 3000R?
Installation, Operation and Maintenance Instructions
– Read and Save These Instructions –
This manual is provided to acquaint you with
the Quest DEH 3000R so that installation,
operation, and maintenance can proceed
successfully. Ultimate satisfaction depends
on the quality of installation and a thorough
understanding of this equipment.
Quest DRY 150
Installation, Operation and Maintenance Instructions
4201 Lien Rd
Madison, WI 53704 1-800-533-7533
www.QuestProtect.com sales@thermastor.com
– Read and Save These Instructions –
Specications subject to change without notice.
TS-721
12/12
1
Quest DEH 3000R Digital Control
Quest DEH 3000R Digital Control:
• Digitalcontrolofrelativehumidity
(DigitalSet-Point)
• Fan/Filteroperation
• Programmableventilationtimer
• Sleekdesign
• Large,easy-to-readbacklitLCDdisplay
• Hightemperaturecut-out
• Dryoutcycletimer
• Autoreboot
quest
quest
quest
quest 1-800-533-7533
2
www.QuestProtect.com
sales@questprotect.com
Quest DEH 3000R Installation, Operation and Maintenance Instructions
Table of Contents
1.Specications.................................................................. 3
2.Installation...................................................................... 3
2.1 ControlPanelInstallInstructions............................. 3
2.2 RemoteSensorInstallInstructions........................... 4
2.3 RemoteSensorUsage............................................. 4
2.4 RemoteSensorWiringInstructions.......................... 4
2.5 ControlPanelWiringInstructions............................ 5
2.6 AuxiliaryRelayOperation....................................... 6
2.7 Dehumidierlock-OFForlock-ON........................ 7
2.8 Testing.................................................................... 8
3.Operation........................................................................ 9
3.1 Display................................................................... 9
3.2 Setting.................................................................. 10
3.3 PersonalSettingsReferenceList............................ 10
3.4 On/OffandDisplaySettings.................................. 10
3.5 SettingClock........................................................ 10
3.6 AdjustingtheRelativeHumidity............................ 11
3.7 FanSettingandOperation.................................... 11
3.8 DamperOperationandSetting(Ventilation)......... 12
3.9 TemperatureCutoutProgramming........................ 14
Warranty............................................................... 15
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
3
www.QuestProtect.com
sales@questprotect.com
quest
quest
24VACYellowWire 24VACRedWire
Damper
WhiteWire
(Optional.See
warningbelow)
Dehumidier
BlueWire
Fan
GreenWire
ON-Detect
Common
OFF-Detect
NormallyOpen
Common
NormallyClosed
Optional
Use
Optional
Use
1. Specications
Part#(P/N)  4028531
Model:  QuestDEH3000RDigitalControl
Electrical:  24VAC
MaxCurrent–
DMP,COMP,FAN:  1Ampeach
HumidityOperatingRange:  10–95%
HumidityControlRange:  35–70%
HumidityAccuracy: 
±
5%
Output:  3Amps24VAC
Aux.RelayCapacity  5Amps
TempRange/  30°-90°F,2%
Accuracy
Size  4.95"Lx1.06"Wx4.19"H
FOR HVAC INSTALLER ONLY:
2. Installation
InstalltheQuestDEH3000Rremotesensorinacentralarea
ofthestructurewhereitwillsensetherelativehumidityofthe
structureaccurately.Donotinstalltheremotesensorwhere
itmaynotaccuratelysensetherelativehumiditysuchasnear
HVACsupplyregisters,nearexteriordoorsandwindows,ornear
apoolorspa.Installinaccordancewithallapplicablecodesand
standards.
2.1 Control Panel Install Instruc-
tions
1. Separatethefrontpanelfromtheback
panelbydepressingthemiddlesections
ofthetopandbottomofthefrontpanel.
2. Locatethewiringaccessholeinthe
wallorotheratmountingsurface.
Placethebackpanelintopositionand
drilltheappropriatemountingholes.
3. Insertthescrewsandtighten.Levelas
necessary.
4. Maketheelectricalconnectionstothe
terminalsonthebackpanelasshownin
theapplicablewiringdiagram(seeSections2.2-2.4).
5. Testtheinstallation(seeSection2.5).
quest
quest 1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
4
www.QuestProtect.com
sales@questprotect.com
2.2 Remote Sensor Install Instructions
This section is applicable only to customers who have purchased a remote
sensor package. The standard DEH 3000 controller does not offer remote
functionality.
2.3 Remote Sensor Usage
IMPORTANT!
•Theuseofspraypaintonthesensorhousingmaydamagethesensorandisnotcoveredbytheproduct
warranty.
Theremotesensingoptionisusedwhenaninstallationrequiresmountingthehumidityandtemperaturesensor
outoftheconditionedspaceorwhenitisdesiredtospecicallymonitorandcontroltheconditionsataparticular
locationinalargerconditionedspace.
Boththeneedforandlocationoftheremotesensorshouldbedeterminedbyaheating/coolingprofessional.
2.4 Remote Sensor Wiring Instructions
1.Routingsignalwires:
Youwillberequiredtosupplyandroute24gauge,4conductorsolidwire(2-linetelephonewire)betweenthe
DEH3000Rcontrollerandtheremotesensorlocation.•Donotrunwireslongerthan100ft.
•Theuseof24gaugewireisoptimal.Thinnergaugewiremaylimitsensordistance.Thickergaugeswillnotwork
withspliceconnectorsprovided.
•Avoidroutingparalleltohighvoltagewiring.
•Maintainadistanceof2ft.ormorefromhighvoltagelines.
2.Sensorconnection:
Thesensorcanbemountedtoawallorceilingsurface.Idealsensorlocationis5ft.abovetheoor.Wires
shouldexitthrougha½”diameterholeinthemountingsurfaceatthemountinglocation.Usetheprovidedsplice
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
5
www.QuestProtect.com
sales@questprotect.com
quest
quest
connectorstoconnectthe4wiresfromtheremotesensortotheuser-suppliedinterconnectwire.Besuretokeep
propercolorsattachedtoeachother.
3.Sensormounting:
Youwillneedtwoscrewstomountthesensor.Usethetwoslottedholestomountthebaseofthesensortothe
wallandthensnapthecoverintoplace.
4.Controllerconnection:
Usetheprovidedspliceconnectorstoconnectthe4wiresfromtheDEH3000Rtotheuser-suppliedinterconnect
wire.Besuretokeepthepropercolorsattachedtoeachother.
Continuewiththeinstallationasdescribedintherestofthismanual.
2.5 Control Panel Wiring Instructions
WARNING! DO NOT ALLOW THE YELLOW WIRE FROM THE QUEST DEHUMIDIFIER
TO CONTACT THE RED OR WHITE WIRES FROM THE QUEST DEHUMIDIFIER, DAMAGE TO THE 24-VOLT
TRANSFORMER WILL RESULT.
WARNING! THE QUEST DEH 3000R DIGITAL CONTROL OPERATES ON A LOW
VOLTAGE CIRCUIT (24 VAC) AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE
CIRCUIT.
WARNING! UNPLUG THE QUEST DEHUMIDIFIER BEFORE WIRING THE DEH 3000R.
Theinstallermustsupplyalleldwiring,includingthewiringbetweentheQUESTdehumidierand
theQuestDEH3000R.SomeofthecontrolwiresleavingtheQUESTdehumidiermaynotbeused
insomecontrolsituationsandshouldbeleftdisconnectedwithwirenutstapedontothestripped
ends.
BesuretoconsulttheelectricalschematicinthismanualortheinternalelectricalboxoftheQuest
dehumidierbeforemakinganycontrolconnections.
WARNING! ONLY CONNECT THE WHITE WIRE TO THE CONTROL IF IT IS WIRED IN A
CIRCUIT THROUGH AN ELECTRIC DAMPER, OTHERWISE TRANSFORMER DAMAGE MAY RESULT.
quest
quest 1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
6
www.QuestProtect.com
sales@questprotect.com
TheWhitewirecontrolstheoptionalmotorizeddamperthatcanbeinstalledintoafreshair
duct.Thisdamperprovidestheabilitytocontrolfreshairventilationusingtheventilation
timerfunctionoftheQuestDEH3000Randtheterminal
labeled“DMP” (SeeSection3.8).Leavethe“DMP”
terminalunusedifamotorizeddamperisnotused,and
capofftheWhitewirefromtheQuestdehumidier.
Standard wire colors for thermostats are as follows:
Description Color Terminal code
24VAC Red R
CallforHeat White WorW1
ForceFanOn Green G
Compressor
CallforCooling Yellow YorY1
2.6 Auxiliary Relay Operation
Itmaybedesirabletocoordinatefanoperationofthecentral
heating/coolingsystemwithdehumidierfanoperation.The
QuestDEH3000Rcontainsarelaythatprovidesthisability.
TherelayterminalslabeledNC,COMandNOoperate
accordingtothefollowingchart:
FAN COM to NO COM to NC
ON CONNECTED OPEN
OFF OPEN CONNECTED
Commonuses(assumingstandardthermostatwiringcolorsas
noted):
NO
COM
NC
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
7
www.QuestProtect.com
sales@questprotect.com
quest
quest
Lock-out the A/C during dehumidier fan operation
ThiswillturnofftheA/Cwheneverthedehumidierfanruns.
1.WiretheYellowthermostatterminaltotheNCterminalontheQuestDEH3000R.Theinstaller
mustsupplythewiringbetweentheQuestdehumidierandthecontrolpanel.Besuretosafelyroutethe
controlwirestopreventdamageduringinstallation.Be
carefulnottocrossthewireswhenconnectingtheQuest
dehumidierandtheremotecontrolpanelordamageto
thetransformermayresult.
2.RuntheYellowwirefromtheA/CunittotheCOM
terminalontheQuestDEH3000R.
Energize the A/C central fan during dehumidier fan
operation
ToautomaticallyruntheA/CFANwhenthedehumidier
fanruns.
1.AttachasecondGreenwiretotheGreenfanwire
terminalonthethermostat.
2.ConnectthenewGreenwiretotheCOMterminalonthe
QuestDEH3000R.
3.RunawirefromtheRedterminalonthethermostatto
theNO(NormallyOpen)terminalontheQuestDEH
3000R.
2.7 Dehumidier lock-OFF or lock-ON:
A/C sensor feature
Toautomaticallyactivateordeactivatethedehumidierwhentheairconditionerruns.
Activate dehumidication when the air-conditioner is running.
A voltmeter is required for the next steps to ensure the correct wiring from
the A/C transformer is used to set up the Lock-in dehumidier function.
1.ThecommonwirefromtheexistingA/Ctransformer(usuallyBlack)
mustbeattachedtothe“COM”sensorterminalbetween“ON-D”
and“OFF-D”ontheDEH3000R.
TIP: The common wire can be identied as the wire from the A/C
transformer that reads 0 volts between it and the Yellow air conditioning call
for cooling wire.The incorrect wire will give a 20 to 28 volt reading.
2.AnotherYellowwiremustbeaddedtothe
thermostatYellowterminalandruntothe“ON-D”
sensorterminalontheQuestDEH3000R.
A/C
Unit
Red
Green
Yellow
A/C
Unit
Red
Green
Yellow
A/C
Unit
Red
Green
Yellow
A/C
Unit
Red
Green
Yellow
ON-D
COM
OFF-D
TO A/C
TO A/C
quest
quest 1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
8
www.QuestProtect.com
sales@questprotect.com
Deactivate dehumidication when the air-conditioner is running.
Avoltmeterisrequiredforthenextstepstoensurethe
correctwiringfromtheA/Ctransformerisusedtosetup
theLock-outdehumidierfunction.
1. ThecommonwirefromtheexistingA/C
transformer(usuallyBlack)mustbeattachedto
the“COM”sensorterminalbetween“ON-D”
and“OFF-D”ontheDEH3000R.
TIP: The common wire can be identied as the wire
from the A/C transformer that reads 0 volts between
it and the Yellow air conditioning call for cooling wire.
The incorrect wire will give a 20 to 28 volt reading.
2.AnotherYellowwiremustbeaddedtothethermostatYellowterminalandruntothe“OFF-D”
sensorterminalontheDEH3000R.
2.8 Testing
Verifythewiringconnections.
WARNING! ONLY CONNECT THE WHITE WIRE TO THE CONTROL IF IT IS WIRED IN
A CIRCUIT THROUGH AN ELECTRIC DAMPER, OTHERWISE TRANSFORMER DAMAGE MAY RESULT.
Aftercheckingthewiring,thisshorttestwillconrmproperhook-up.
1. InstallfrontcoveroftheQuestDEH3000R;connectthetoprst,thenthebottom.
2.PlugintheQUESTdehumidier.TheQuestDEH3000Rshouldpowerup.
3.TurntheQuestDEH3000RONbypressingtheON/OFFbutton.
4.VerifydehumidicationoperationbyadjustingtheRHSETPOINTtobelowthe“%RH”
readingonthedisplay.UsethedownRHbutton.ConrmQuestfanandcompressor
operation.BothshouldbeONnow.
IncreasetheRHSETPOINTonthedisplaytowellabovethe“%RH”readingonthedisplay.Pressthe“RH”
uparrowtoincreasetheRHSETPOINT.
AfterrunningthedehumidiercompressortheQuestDEH3000Rappliesa10minuterestartlockoutonall
functions.Youwillhavetowaitfortherestartlockouttoexpire.
5.VerifyFAN-onlyoperation:
a.ChecktheVENTmodeonthedisplay,itwilleitherbeCLOSEDorOPEN.IfitisCLOSEDgoto
thenextstep.IfitisOPEN,pressandholdtheVENTkeyuntil“OPENashesonthedisplay,release
thekeyandthenpressitonemoretime.OPENwillchangetoCLOSED.Don’ttouchthekeysfor
severalsecondsuntilitstopsashing.
b.PressandholdtheFANbuttonuntilAUTObeginsashingonthedisplay,releaseit,andthenpressit
againtoswitchthefantotheONsetting.
c.ConrmthattheQUESTfanisON.QuestcompressormustbeOFF.Ventilationdamper(ifused)should
beCLOSED.
6.VerifyoptionalVENToperation(ifelectricdamperisinstalled):
a.PressandholdtheFANbuttonuntilONashesonthedisplay.
b.ReleasetheFANbutton,thenpressitagaintoswitchfanoperationtoAUTO.
TO A/C
TO A/C
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
9
www.QuestProtect.com
sales@questprotect.com
quest
quest
c.PressandholdtheVENTbuttonuntilCLOSEDashesonthedisplay.
d.ReleasetheVENTbutton,thenpressitagaintoswitchventmodetoOPEN.
e.ConrmthattheQuestfanisON.VentilationdamperisOPEN.QUESTcompressormustbeOFF.
f.PressandholdtheVENTbuttonuntiltheOPENashesonthedisplay.
g.ReleasetheVENTbutton,thenpressitagaintoswitchventmodetoCLOSED.
Troubleshooting:
Ifanyfunctionsarenotworkingproperly,checkthewiringandconnections.Avoltmetermaybeusedacross
terminalstoverifyvoltage.Ifthereisconcernaboutthedehumidiernotoperatingproperly,theleadsexitingthe
QUESTdehumidiermaybeconnectedaccordingtothefollowingchart:
Wire connections Operation
Yellow&Blue Fan&Compressor
Yellow&Green FanOnly
WARNING!DO NOT MAKE ANY OTHER CONNECTIONS OR TRANSFORMER DAMAGE
MAY RESULT.
7.VerifyanyadditionaloptionalcontroloperationssuchasfaninterlockorA/Clockout.
8.ProceedtotheOperationsection.
FOR INSTALLER & OWNER:
3. Operation
Onthedisplayscreen,asolidOinfrontofanyofthe3functions(SETPOINT,VENT,FAN)indicatesthefunction
isoperating.AashingOindicatesitisinawaitmodeandnotavailableatthemoment.NoOindicatesthe
functioniscurrentlyOFF.
SolidObefore Indicates
SETPOINT Dehumidieron
VENT Freshairventilationcycleinprogress
FAN Fanon
Waitmodeisafactory-programmedtimeperiodmeanttopreventshortcycles.Thisextendsthelifeofthe
dehumidier.WhenaashingOisencountered,theunitisinwaitmodeandIT COULD BE UP TO 10
MINUTES BEFORE OPERATION RESUMES.
3.1 Display
•Wheneverthereispowertothecontrol,itwilldisplaythetime,theday,%relativehumidity,andtemperature.
•WhenthecontrolisactuallyswitchedON,the%RHsetpoint,fanstatus,runmode(programorhold),andfresh
airventilationstatusisdisplayed.
•Whenakeyispressedthedisplaywilllightforapproximately½aminute.
•TheTimeandDayisdisplayedatthetopofthescreen.
quest
quest 1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
10
www.QuestProtect.com
sales@questprotect.com
•RHandTemperaturearedisplayedinrealtime.
•AsolidObeforetheSETPOINT,VENT,ORFANindicatesthefunctionis
operating.
•AashingObeforetheSETPOINT,VENT,ORFANindicatestheunitis
inwaitmode.
3.2 Setting
Duringtheset-upprocess,ifyoumakeamistake,simplycontinue.Youcanalwaysgobacktoadjustthesettings.
Ifyouleavethecontrolaloneanddon’ttouchanybuttonsfor10seconds,thecontrolwillrememberany
changesmadeandreturntothenormaldisplayscreen,allowingyoutoproceedtothenextstep.
3.3 Personal Settings reference list
Please record your settings here.
Function Factory setting My Setting
SETPOINT(%RH) 50%
VENT Closed
FAN Auto
TEMPCUTOUT 99°
3.4 On/Off and display items
Pressthe“ON/OFFbuttontoturnthesystemONorOFF.
WhenthesystemisON,thesetpoint,fanstatus,operationmode(RUNor
HOLD),andfreshairventstatusisdisplayed.
WhenthesystemisOFF,thecontrolwilldisplaythetime,day,%RH,and
temperature.
Whentheunitisshipped,itisinmanual(hold)mode.
3.5 Setting Clock Time
1.PressandholdtheCLOCKbutton.Thehourdisplaywillash.Release
thebutton.
2.Usetheup/downRHbuttonstochangethevalue.
3.PresstheCLOCKbuttonagainandtheminutedisplaywillash.Use
theRH”buttonstochangethevalue.
4.PresstheCLOCKbuttonagainandAMorPMwillash.UsetheRHbuttonstochangethevalue.
5.Pressthe“CLOCK”buttonagainandthedaydisplaywillash.Usethe“RH”buttonstochangethevalue.
6.Don’ttouchanybuttonsforseveralsecondsuntilthedisplaystopsashing,thiswillsaveyoursettings.Ifyou
needtochangeanythinggobacktostep#1.
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
11
www.QuestProtect.com
sales@questprotect.com
quest
quest
3.6 Adjusting the relative humidity “SETPOINT”
TheQuestDEH3000Rsensestheambientrelativehumidity(%RH)ofthespaceinwhichitislocated,itcomes
factorypresettohold50%relativehumidity.
TherelativehumiditySETPOINT(desiredRHtobemaintained)operates
thedehumidierfunctionoftheQuestdehumidier.Ithasnoeffectonthe
optionalVENT(freshairventilation)orFAN(airrecirculation)functionsifthey
arebeingused.
Operation
ThestandardrangethatthedehumidierholdsaroundyourSETPOINT”
is3%.Withasetpointof50%,thedehumidierwillrununtiltherelative
humidityreaches47%.Thedehumidierwillthenswitchoffuntiltherelative
humidityreaches53%.
Ifthesetpointishigherthantheambientrelativehumidity,thespacedoesnotneedtobedehumidiedsothe
dehumidierwillnotrun.
Example:Setpoint:50%RH
Currentcondition:45%RH–Thedehumidierwillbeoff(noOindicatorwillbedisplayed).
Ifyoursetpointisbelowtheambientcondition,thedehumidierwillbeonandOwilldisplay.
Example:Setpoint:50%RH
Currentcondition:55%RH–Thedehumidierwillbeon(O”displayed).
3.7 Fan Setting and Operation
UsetheFANbuttontochangethefanoperation.Thereare2choicesforfanoperation:ONorAUTO.The
factorypresetisAUTO.
ON–ThefanintheQuestdehumidierwillruncontinuously.Thisdoesnotaffecteitherthedehumidication
orventilationfunctionsofthesystem.Thesystemmayormaynotbeventilatingordehumidifyingwhilethefanis
running.Thissettingiscommonlyusedformaximumairltrationand/orairrecirculation.
AUTO–IndicatesthefanwillrunwhentheQuestDEH3000Rcallsfordehumidicationorventilation.Ifthe
controlhasnotcalledfordehumidicationfor3hours,thecontrolwillautomaticallyrunthedehumidierfanfor
10minutes.
Afteradehumidicationcycle,thefanautomaticallyshutsofffor10minutes.Thispauseallowsthewatertodrain
fromthedehumidier.
AsolidOindicatesthefanisoperating.AashingOindicatesthefanisinawaitmode.NoOindicatesthe
fanisOFF.
Tosettheoperation:
1.PressandholdtheFANbutton.Thecurrentfansettingwillbegintoash
onthedisplay.Releasethebutton.
2.PresstheFAN”buttontotogglebetweentheONandAUTOmodes.
WiththefanintheAUTO”mode,thefanwilloperateonlywhenneeded
byotherfunctionsofthesystem.ThefanwillremainOFFunlessthesystem
isdehumidifyingorventilating.Thefanalwaysrunsduringdehumidication
andventilationandthefanOiconwillbelit.Tocompletelyturnthe
systemOFF,usetheON/OFFbuttonasdescribedearlier.
quest
quest 1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
12
www.QuestProtect.com
sales@questprotect.com
3.8 Damper Operation and Ventilation,
Manual (Hold) Mode
TheVENTsettingcontrolstheventilationfunctionofthesystem.Ithasnocontroloverthedehumidication
function.Inordertoprovideventilation,themotorizeddampermustbeopenandthefanmustberunning.The
controllertakescareofthesetwofunctionsautomaticallysothatwheneverthedamperisopen,thefanisrunning.
TheventilationindicatorOwillbedisplayedwhenevertheunitisventilating.ThefanoperationindicatorO”
willalsobelit.
Therearethreedamperoperationmodes:
1.OPEN–holdmode:Thedamperwillbeopenandthedehumidierfanwillbecontinuouslyoperatingto
introducefreshairintothespace.Usethismodeforcontinuousfreshairventilation.Thefanisalwaysonwhen
thedamperisopen.
2.CLOSED–holdmode:Thedamperwillneveropen,andthedehumidierwillnotventilate.Thefanwillstill
operatenormallyforrecirculationanddehumidication.
3.PROGRAMMEDmode:TheQuestDEH3000Rwilloperatethemotorizeddamperandthedehumidierfan
accordingtotheprogrammedventilationschedule(Section3.9).
ThefactorypresetfortheVENTsettingisCLOSED.
Toset“OPEN”–holdor“CLOSED”–holdventilationoperation:
1.PresstheVENTbutton.Thecurrentsettingwillbegintoashonthedisplay.Releasethebutton.
2.Pressthe“VENTbuttonagaintoswitchbetween“OPEN”andCLOSED.
3.Leavethecontrolalonefor10secondsandyoursettingswillbesaved.
Damper Operation and Ventilation, Programmed Ventilation
Thisexampleshowsthesysteminprogrammode(denotedbytheschedule15minuteson,5minutesoffandthe
wordRUNinthelowerrightcornerofthedisplay).
TheQuestDEH3000Rwilloperatefreshairventilationaccordingtoyour
ventilationprogram.Thecontrolneedstobeprogrammedtoturnthe
ventilationfunctionONandOFFatthedesiredintervals.Thisisdoneby
programmingtheventilationtimer.
Therearetwoprogramsavailableforventilation:
1.MondaythroughSunday
2.MondaythroughFriday&Saturday/Sunday
Eachblockofdayshasamorningscheduleandanightschedule.Morning
istherst12hoursofthedayandnightisthesecond12hours.
Eachschedulehas:
•ASTARTtimewhentheventilationschedulebegins,
•AnOPEN FOR”durationfortheamountoftimethedamperstaysopenin5minuteintervals,from0to60,
•AndCLOSED FORdurationwhichclosesthedamperforaspeciedtimein5minuteintervalsfrom0to60.
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
13
www.QuestProtect.com
sales@questprotect.com
quest
quest
Setting the Ventilation Program:
1.Pressthe“PROGRAM ENTERbuttonuntilthefollowingmenu
appears:
2.Usingtheup/down“RH”buttons,highlightPROGRAMandselect
itbypressingthePROGRAM ENTER”button.Thefollowingmenu
appears:
Youcanselectfrom:
MON-FRI”“SAT-SUNforseparateweekdayandweekendschedules,or
MON-SUNwhichgivesyouequalweekdayandweekendschedules.
3.UsingtheUp/DownRH”buttons,highlightandthenselectoneofthetwochoices.Theexamplegivenshows
howtoprogramseparateweekdayandweekendschedules.Thesamemethodisusedifyouchoosetheother
program.
Example:menuwhenyouselectMON-FRI”“SAT-SUN”:
1.Enterthestartingtimeforweekdaysusingtheup/downRH”buttonstochangethetime.
2.PressthePROGRAM ENTER”buttontoswitchtotheOPEN FORsetting.Usingtheup/down“RH”buttons,
changethedurationthatthedamperwillventilatefreshair.
3.PressthePROGRAMENTERbuttontoswitchtothe“CLOSEDFOR”setting.Usingtheup/downRH”
buttons,changethedurationthatthedamperwillremainclosedbetweenventilationcycles.
Fortheexamplegiven,startingat8:00AMinthemorning,thecontrolwillventilatefreshairfor15minutesthen
stopfor15minutes.Thisscheduleof15minutesopen,15minutesclosedwillcontinueuntilthestarttimeofthe
nightschedule.
Morningscheduleisavailableanytimefrom12:00AMuntil11:59AM.
Nightscheduleisavailableanytimefrom12:00PMuntil11:59PM.
4.Press“PROGRAMENTERagaintogototheMON-FRInightschedule.Repeatthestepslistedaboveforthis
andtheSAT-SUNdayandnightschedules.
quest
quest 1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
14
www.QuestProtect.com
sales@questprotect.com
Whenyouhavenishedprogrammingyourschedule(eitherthe7-dayversionortheweekday/weekendsplit
version),usethedown“RH”buttontohighlighttheEXIToptionandthenpressPROGRAM ENTER”toselectit.
RunningtheVentilationProgram
PressandholdthePROGRAM ENTER”buttonuntilthe“PROGRAMscreenappears.
UsethedownRHbuttontohighlightRUN PROGRAM:
ThenpressPROGRAMENTERtoselectit.Thedisplaywillappearasfollows:
3.9 Temperature Cutout Programming
Dehumidiersproduceheatwhendehumidifyinganddependinguponoutsideconditions,theventilation
functionmayalsointroducewarmair.Someconditionsmayintroduceenoughheattodrivetemperaturesup.
TheQuestDEH3000RtemperaturecutoutfeaturedisablesallQuestoperationsiftemperaturesreachthecutout
setpoint.
Inmostinstallationsthisfeaturewillnotneedtobeused(thecutoutisfactorysetto99°F).Ifalowertemperature
cutoutisdesired,programthesetpointbypressingandholdingthePROGRAMENTERbuttonuntilthe
PROGRAM”screenappears.Presstheup/down“RH”buttonsuntilTEMPCUTOUThighlighted.Thenpress
the“PROGRAMENTERbuttonagaintoselectit.NowusetheRHuporRHdownbuttonstoadjustthe
setpoint.PressPROGRAMENTERtoreturntothehomescreen.
1-800-533-7533
Quest DEH 3000R Installation, Operation and Maintenance Instructions
15
www.QuestProtect.com
sales@questprotect.com
quest
quest
WARRANTOR:
Therma-StorLLC
4201LienRd
Madison,WI53704
Telephone:1-800-533-7533
WHO IS COVERED: Thiswarrantyextendsonlytotheoriginalresidentialend-useroftheQuest
DEH3000RDehumidier&VentilationSystemController,andmaynotbeassignedortransferred.
FIRST YEAR WARRANTY: Therma-StorLLCwarrantsthat,forone(1)yeartheQuestDEH3000R
Dehumidier&VentilationSystemControllerwilloperatefreefromanydefectsinmaterialsand
workmanship,orTherma-StorLLCwill,atitsoption,repairorreplacethedefectivepart(s),freeof
anycharge.
END-USER RESPONSIBILITIES:WarrantyservicemustbeperformedbyaServicerauthorizedby
Therma-StorLLC.Iftheend-userisunabletolocateorobtainwarrantyservicefromanauthorized
Servicer,heshouldcallTherma-StorLLCattheabovenumberandaskfortheTherma-StorLLC
ServiceDepartment,whichwillthenarrangeforcoveredwarrantyservice.Warrantyservicewillbe
performedduringnormalworkinghours.
TheEnd-usermustpresentproofofpurchase(lease)uponrequest,byuseofthewarrantycardor
otherreasonableandreliablemeans.Theend-userisresponsiblefornormalcare.Thiswarrantyonly
appliestoresidentialapplicationsanddoesnotcoveranydefect,malfunction,etc.resultingfrom
misuse,abuse,lackofnormalcare,corrosion,freezing,tampering,modication,unauthorizedor
improperrepairorinstallation,accident,actsofnatureoranyothercausebeyondTherma-StorLLC's
reasonablecontrol.
LIMITATIONS AND EXCLUSIONS:IfanyQuestDEH3000RDehumidier&VentilationSystem
Controllerpartisrepairedorreplaced,thenewpartshallbewarrantedforonlytheremainderofthe
originalwarrantyperiodapplicablethereto(butallwarrantyperiodswillbeextendedbytheperiod
oftime,ifany,thattheQuestDEH3000RDehumidier&VentilationSystemControllerisoutof
servicewhileawaitingcoveredwarrantyservice).
UPONTHEEXPIRATIONOFTHEWRITTENWARRANTYAPPLICABLETOTHEQuestDEH3000R
Dehumidier&VentilationSystemControllerORANYPARTTHEREOF,ALLOTHERWARRANTIES
IMPLIED BY LAW, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, SHALLALSO EXPIRE.  ALLWARRANTIES MADE BYTHERMA-STOR LLC ARE SET
FORTHHEREIN,ANDNOCLAIMMAYBEMADEAGAINSTTHERMA-STORLLCBASEDONANY
ORAL WARRANTY. IN NO EVENT SHALLTHERMA-STOR LLC, IN CONNECTION WITHTHE
SALE,INSTALLATION,USE,REPAIRORREPLACEMENTOFANYQuestDEH3000RDehumidier
&VentilationSystemControllerORPARTTHEREOFBELIABLEUNDERANYLEGALTHEORYFOR
ANYSPECIAL,INDIRECTORCONSEQUENTIALDAMAGESINCLUDINGWITHOUTLIMITATION
WATER DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST
PROFITS,DELAY,ORLOSSOFUSEORDAMAGETOANYREALORPERSONALPROPERTY.
Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,andsomedonotallow
theexclusionorlimitationofincidentalorconsequentialdamages,sooneorbothoftheselimitation
maynotapplytoyou.
LEGAL RIGHTS: Thiswarrantygivesyouspeciclegalrights,andyoumayalsohaveotherrights
whichvaryfromstatetostate.
/