BEA Door Position Switches User guide

Type
User guide
75.5944.01 DOOR POSITION SWITCHES 20180406 Page 1 of 4
DOOR POSITION SWITCHES
75.5944.01 DOOR POSITION SWITCHES 20180406 Page 1 of 4
Magnetic, contact switches
(US version)
ENGLISH
DESCRIPTION
DPS 1277
DPS 1076
DPS 1084
DPS 1075
TECHNICAL SPECIFICATIONS
1277 1075 1076 1084
Voltage Max.: 30 VAC/VDC 175 VDC 30 VAC/VDC 30 VAC/VDC
Current Max.: 0.25 A 0.25 A 0.25 A 0.25 A
Power Max.: 3.0 W 5.0 W 3.0 W 3.0 W
Electrical Configuration: SPDT SPDT SPDT SPDT
Wiring (12” 22AWG):
NO: red
NC: white
COM: black
NO: red
NC: white
COM: black
NO: red
NC: white
COM: black
Open or Closed
Gap Distance Max.: 0.50” (13mm) 0.5” 0.75” (up to) / 2.00” 2.00”
Reed Form: N/A C N/A N/A
Initial Contact Resistance Max.: N/A 0.140 Ω N/A N/A
Specifications are subject to change without prior notice.
All values measured in specific conditions.
Page 2 of 4 75.5944.01 DOOR POSITION SWITCHES 20180406
PRECAUTIONS
Page 2 of 4 75.5944.01 DOOR POSITION SWITCHES 20180406
READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP
Only trained and qualified personnel are
recommended to install and set up the
sensor.
The warranty is invalid if unauthorized
repairs are made or attempted by
unauthorized personnel.
Always test the proper operation of the
installation before leaving the premises.
The door control system and the
header cover profile must be correctly
grounded.
Shut off all power going to header before attempting any wiring procedures.
Maintain a clean and safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the area.
Always stop pedestrian traffic through the doorway when performing tests that may result in
unexpected reactions by the door.
Always check placement of all wiring before powering up to ensure that moving door parts will not
catch any wires and cause damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10/19) upon completion of
installation.
DO NOT attempt any internal repair of the components. All repairs and/or component replacements
must be performed by BEA, Inc. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided
warranty.
75.5944.01 DOOR POSITION SWITCHES 20180406 Page 3 of 4
DPS 1277
DPS 1076
DPS 1075
Ø 0.44”
0.60”
0.78”
75.5944.01 DOOR POSITION SWITCHES 20180406 Page 3 of 4
INSTALLATION
1. Drill a hole
3
8” in diameter and 1” deep for the contact.
2. Drill a hole
3
8” in diameter and 1
3
8” deep for the magnet. “Wings” on contact allow for
expansion if the hole is slightly oversized. See dimensions below.
3. Press the magnet into the door and then push the contact into the door frame.
4. Connect the NO (or NC) and COM from the contact to the applicable circuit.
1. Drill a hole
3
4” in diameter and 1
1
8” deep for the contact.
2. Drill a hole
3
4” in diameter and 1
1
8” deep for the magnet. See dimensions below.
3. Press the magnet into the door and then push the contact into the door frame.
4. Connect the NO (or NC) and COM from the contact to the applicable circuit.
1. Drill a hole
3
8” in diameter for the contact.
2. Drill a hole
3
8” in diameter for the switch.
See dimensions, right.
3. Press the magnet into the door.
4. Press the switch into the frame.
5. Connect the NO (or NC) and COM from the contact to the applicable circuit.
Ø 0.425”
NOTE: Wings compress to Ø 0.375”.
0.275”
0.375”
1.000”
1.313”
1.313”
Ø 0.875”
1.563”
1.125”
0.750”
0.750”
0.375”
Page 4 of 4 75.5944.01 DOOR POSITION SWITCHES 20180406
©BEA | 75.5944.01 DOOR POSITION SWITCHES 20180406
DPS 1084
Page 4 of 4 75.5944.01 DOOR POSITION SWITCHES 20180406
BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA
does not guarantee any use of the sensor outside of its intended purpose.
BEA strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-
trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor
system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL 325).
Verify that all appropriate industry signage and warning labels are in place.
BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
PLEASE KEEP FOR FURTHER USE – DESIGNED FOR COLOR PRINTING
Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
General Tech Questions: T[email protected] | Tech Docs: www.BEAinc.com
| Original Instructions
1. Determine mounting location on door frame.
2. Mark and drill two holes for mounting the switch.
3. Mount the switch to the frame with the screws.
4. Align the magnet on the door with the switch.
5. Mark and drill two holes for mounting the magnet.
6. Mount the magnet with the screws.
7. Wire the switch as needed for the application.
INSTALLATION (cont.)
0.56”
1.42cm
0.41”
1.04cm
0.22”
0.56cm
2.11”
5.36cm
1.73”
4.39cm
0.13”
0.33cm
0.50”
1.27cm
sensing face
0.28”
0.71cm
0.50”
1.27cm
1.72”
4.37cm
0.41”
1.04cm
0.22”
0.56cm
0.13”
0.33cm
0.77”
1.96cm
0.56”
1.42cm
2.11”
5.36cm
sensing face
0.25”
0.64cm
ACTUATOR
SWITCH
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

BEA Door Position Switches User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI