BEA Door Position Switches offer reliable detection of door position for a variety of applications. With models like DPS 1277, DPS 1084, DPS 1076, and DPS 1075, these switches provide accurate sensing of door status, ensuring safety and efficient operation. Whether you need to monitor the position of sliding, swinging, or overhead doors, BEA switches deliver precise detection. Their compact size and easy installation make them ideal for various commercial, industrial, and residential applications.

BEA Door Position Switches offer reliable detection of door position for a variety of applications. With models like DPS 1277, DPS 1084, DPS 1076, and DPS 1075, these switches provide accurate sensing of door status, ensuring safety and efficient operation. Whether you need to monitor the position of sliding, swinging, or overhead doors, BEA switches deliver precise detection. Their compact size and easy installation make them ideal for various commercial, industrial, and residential applications.

75.5944.02 DOOR POSITION SWITCHES 20201208 Page 1 of 4
DOOR POSITION SWITCHES
75.5944.02 DOOR POSITION SWITCHES 20201208 Page 1 of 4
Magnetic, contact switches
(US version)
ENGLISH
DESCRIPTION
DPS 1277
DPS 1076
DPS 1084
DPS 1075
TECHNICAL SPECIFICATIONS
1277 1075 1076 1084
Voltage Max.: 30 VAC/VDC 175 VDC 30 VAC/VDC 30 VAC/VDC
Current Max.: 0.25 A 0.25 A 0.25 A 0.25 A
Power Max.: 3.0 W 5.0 W 3.0 W 3.0 W
Electrical Configuration: SPDT SPDT SPDT SPDT
Wiring (12” 22AWG):
NO: green
NC: red
COM: white
NO: green
NC: red
COM: white
NO: green
NC: red
COM: white
Open (red) or
Closed (green)
Gap Distance Max.: 0.50” (13mm) 0.5” 0.75” (up to) / 2.00” 2.00”
Reed Form: N/A C N/A N/A
Initial Contact Resistance Max.: N/A 0.140 Ω N/A N/A
Specifications are subject to change without prior notice.
All values measured in specific conditions.
Page 2 of 4 75.5944.02 DOOR POSITION SWITCHES 20201208Page 2 of 4 75.5944.02 DOOR POSITION SWITCHES 20201208
READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP
Only trained and qualified personnel are
recommended to install and set up the
sensor.
The warranty is invalid if unauthorized
repairs are made or attempted by
unauthorized personnel.
Always test the proper operation of the
installation before leaving the premises.
The door control system and the
header cover profile must be correctly
grounded.
Shut off all power going to header before attempting any wiring procedures.
Maintain a clean and safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the area.
Always stop pedestrian traffic through the doorway when performing tests that may result in
unexpected reactions by the door.
Always check placement of all wiring before powering up to ensure that moving door parts will not
catch any wires and cause damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10/19) upon completion of
installation.
DO NOT attempt any internal repair of the components. All repairs and/or component replacements
must be performed by BEA, Inc. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided
warranty.
PRECAUTIONS
!
CAUTION
75.5944.02 DOOR POSITION SWITCHES 20201208 Page 3 of 4
DPS 1277
DPS 1076
DPS 1075
Ø 0.44”
0.60”
0.78”
Ø 0.425”
NOTE: Wings compress to Ø 0.375”.
0.275”
0.375”
1.000”
1.313”
1.313”
Ø 0.875”
1.563”
1.125”
0.750”
0.750”
0.375”
75.5944.02 DOOR POSITION SWITCHES 20201208 Page 3 of 4
INSTALLATION
1. Drill a hole
3
8” in diameter and 1” deep for the contact.
2. Drill a hole
3
8” in diameter and 1
3
8” deep for the magnet. “Wings” on contact allow for
expansion if the hole is slightly oversized. See dimensions below.
3. Press the magnet into the door and then push the contact into the door frame.
4. Connect the NO (or NC) and COM from the contact to the applicable circuit.
1. Drill a hole
3
4” in diameter and 1
1
8” deep for the contact.
2. Drill a hole
3
4” in diameter and 1
1
8” deep for the magnet. See dimensions below.
3. Press the magnet into the door and then push the contact into the door frame.
4. Connect the NO (or NC) and COM from the contact to the applicable circuit.
1. Drill a hole
3
8” in diameter for the contact.
2. Drill a hole
3
8” in diameter for the switch.
See dimensions, right.
3. Press the magnet into the door.
4. Press the switch into the frame.
5. Connect the NO (or NC) and COM from the contact to the applicable circuit.
Page 4 of 4 75.5944.02 DOOR POSITION SWITCHES 20201208
DPS 1084
0.56”
1.42cm
0.41”
1.04cm
0.22”
0.56cm
2.11”
5.36cm
1.73”
4.39cm
0.13”
0.33cm
0.50”
1.27cm
sensing face
0.28”
0.71cm
0.50”
1.27cm
1.72”
4.37cm
0.41”
1.04cm
0.22”
0.56cm
0.13”
0.33cm
0.77”
1.96cm
0.56”
1.42cm
2.11”
5.36cm
sensing face
0.25”
0.64cm
Page 4 of 4 75.5944.02 DOOR POSITION SWITCHES 20201208
1. Determine mounting location on door frame.
2. Mark and drill two holes for mounting the switch.
3. Mount the switch to the frame with the screws.
4. Align the magnet on the door with the switch.
5. Mark and drill two holes for mounting the magnet.
6. Mount the magnet with the screws.
7. Wire the switch as needed for the application.
INSTALLATION (cont.)
ACTUATOR
SWITCH
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore,
BEA, Inc. does not guarantee any use of the sensor outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and
factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor
system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107).
Verify that all appropriate industry signage and warning labels are in place.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
Tech Support & Customer Service: 1-800-523-2462
General Tech Questions: [email protected] | Tech Docs: www.BEAsensors.com
©BEA | Original Instructions | PLEASE KEEP FOR FURTHER USE - DESIGNED FOR COLOR PRINTING
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

BEA Door Position Switches User guide

Type
User guide

BEA Door Position Switches offer reliable detection of door position for a variety of applications. With models like DPS 1277, DPS 1084, DPS 1076, and DPS 1075, these switches provide accurate sensing of door status, ensuring safety and efficient operation. Whether you need to monitor the position of sliding, swinging, or overhead doors, BEA switches deliver precise detection. Their compact size and easy installation make them ideal for various commercial, industrial, and residential applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI