Mitsubishi Electric MR-JE-_A SERVO AMPLIFIER User manual

  • Hello! I am an AI chatbot trained to assist you with the Mitsubishi Electric MR-JE-_A SERVO AMPLIFIER User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SH(NA)030128ENG-J(1708)MEE Printed in Japan Specifications are subject to change without notice.
This Instruction Manual uses recycled paper.
MODEL
MODEL
CODE
General-Purpose AC Servo
MR-JE-_A SERVO AMPLIFIER INSTRUCTION MANUAL
HEAD OFFICE: TOKYO BLDG MARUNOUCHI TOKYO 100-8310
MODEL
MR-JE-_A
SERVO AMPLIFIER
INSTRUCTION MANUAL
General-Purpose Interface AC Servo
1CW706
MR-JE-A SERVOAMPLIFIER
INSTRUCTIONMANUAL
J
J
A - 1
Safety Instructions
Please read the instructions carefully before using the equipment.
To use the equipment correctly, do not attempt to install, operate, maintain, or inspect the equipment until
you have read through this Instruction Manual, Installation guide, and appended documents carefully. Do not
use the equipment until you have a full knowledge of the equipment, safety information and instructions.
In this Instruction Manual, the safety instruction levels are classified into "WARNING" and "CAUTION".
WARNING
Indicates that incorrect handling may cause hazardous conditions,
resulting in death or severe injury.
CAUTION
Indicates that incorrect handling may cause hazardous conditions,
resulting in medium or slight injury to personnel or may cause physical
damage.
Note that the CAUTION level may lead to a serious consequence according to conditions.
Please follow the instructions of both levels because they are important to personnel safety.
What must not be done and what must be done are indicated by the following diagrammatic symbols.
Indicates what must not be done. For example, "No Fire" is indicated by
.
Indicates what must be done. For example, grounding is indicated by
.
In this Instruction Manual, instructions at a lower level than the above, instructions for other functions, and so
on are classified into "POINT".
After reading this Instruction Manual, keep it accessible to the operator.
A - 2
1. To prevent electric shock, note the following
WARNING
Before wiring and inspections, turn off the power and wait for 15 minutes or more until the charge lamp
turns off. Otherwise, an electric shock may occur. In addition, when confirming whether the charge lamp
is off or not, always confirm it from the front of the servo amplifier.
Ground the servo amplifier and servo motor securely.
Any person who is involved in wiring and inspection should be fully competent to do the work.
Do not attempt to wire the servo amplifier and servo motor until they have been installed. Otherwise, it
may cause an electric shock.
Do not operate switches with wet hands. Otherwise, it may cause an electric shock.
The cables should not be damaged, stressed, loaded, or pinched. Otherwise, it may cause an electric
shock.
To prevent an electric shock, always connect the protective earth (PE) terminal (marked ) of the servo
amplifier to the protective earth (PE) of the cabinet.
To avoid an electric shock, insulate the connections of the power supply terminals.
2. To prevent fire, note the following
CAUTION
Install the servo amplifier, servo motor, and regenerative resistor on incombustible material. Installing
them directly or close to combustibles will lead to smoke or a fire.
Always connect a magnetic contactor between the power supply and the power supply (L1/L2/L3) of the
servo amplifier, in order to configure a circuit that shuts down the power supply on the side of the servo
amplifier’s power supply. If a magnetic contactor is not connected, continuous flow of a large current may
cause smoke or a fire when the servo amplifier malfunctions.
Always connect a molded-case circuit breaker, or a fuse to each servo amplifier between the power
supply and the power supply (L1/L2/L3) of the servo amplifier, in order to configure a circuit that shuts
down the power supply on the side of the servo amplifier’s power supply. If a molded-case circuit breaker
or fuse is not connected, continuous flow of a large current may cause smoke or a fire when the servo
amplifier malfunctions.
When using the regenerative resistor, switch power off with the alarm signal. Otherwise, a regenerative
transistor malfunction or the like may overheat the regenerative resistor, causing smoke or a fire.
When you use a regenerative option with an MR-JE-40A to MR-JE-100A, remove the built-in
regenerative resistor and wiring from the servo amplifier.
Provide adequate protection to prevent screws and other conductive matter, oil and other combustible
matter from entering the servo amplifier and servo motor.
3. To prevent injury, note the following
CAUTION
Only the power/signal specified in the Instruction Manual must be supplied/applied to each terminal.
Otherwise, an electric shock, fire, injury, etc. may occur.
Connect cables to the correct terminals. Otherwise, a burst, damage, etc. may occur.
Ensure that polarity (+/-) is correct. Otherwise, a burst, damage, etc. may occur.
The servo amplifier heat sink, regenerative resistor, servo motor, etc., may be hot while the power is on
and for some time after power-off. Take safety measures such as providing covers to avoid accidentally
touching them by hands and parts such as cables.
A - 3
4. Additional instructions
The following instructions should also be fully noted. Incorrect handling may cause a malfunction, injury,
electric shock, fire, etc.
(1) Transportation and installation
CAUTION
Transport the products correctly according to their mass.
Stacking in excess of the specified number of product packages is not allowed.
Do not hold the lead of the built-in regenerative resistor, cables, or connectors when carrying the servo
amplifier. Otherwise, it may drop.
Install the servo amplifier and the servo motor in a load-bearing place in accordance with the Instruction
Manual.
Do not get on or put heavy load on the equipment. Otherwise, it may cause injury.
The equipment must be installed in the specified direction.
Leave specified clearances between the servo amplifier and the cabinet walls or other equipment.
Do not install or operate the servo amplifier and servo motor which have been damaged or have any
parts missing.
Do not block the intake and exhaust areas of the servo amplifier. Otherwise, it may cause a malfunction.
Do not drop or apply heavy impact on the servo amplifiers and the servo motors. Otherwise, injury,
malfunction, etc. may occur.
Do not strike the connector. Otherwise, a connection failure, malfunction, etc. may occur.
When you keep or use the equipment, please fulfill the following environment.
Item Environment
Ambient
temperature
Operation 0 °C to 55 °C (non-freezing)
Storage -20 °C to 65 °C (non-freezing)
Ambient
humidity
Operation
5 %RH to 90 %RH (non-condensing)
Storage
Ambience Indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust, and dirt
Altitude 2000 m or less above sea level (Contact your local sales office for the altitude for options.)
Vibration resistance 5.9 m/s
2
, at 10 Hz to 55 Hz (directions of X, Y and Z axes)
When the product has been stored for an extended period of time, contact your local sales office.
When handling the servo amplifier, be careful about the edged parts such as corners of the servo
amplifier.
The servo amplifier must be installed in a metal cabinet.
When fumigants that contain halogen materials such as fluorine, chlorine, bromine, and iodine are used
for disinfecting and protecting wooden packaging from insects, they cause malfunction when entering our
products. Please take necessary precautions to ensure that remaining materials from fumigant do not
enter our products, or treat packaging with methods other than fumigation (heat method). Additionally,
disinfect and protect wood from insects before packing products.
To prevent a fire or injury from occurring in case of an earthquake or other natural disasters, securely
install, mount, and wire the servo motor in accordance with the Instruction Manual.
A - 4
(2) Wiring
CAUTION
Before removing the CNP1 connector of MR-JE-40A to MR-JE-100A, disconnect the lead wires of the
regenerative resistor from the CNP1 connector.
Wire the equipment correctly and securely. Otherwise, the servo motor may operate unexpectedly.
Make sure to connect the cables and connectors by using the fixing screws and the locking mechanism.
Otherwise, the cables and connectors may be disconnected during operation.
Do not install a power capacitor, surge killer, or radio noise filter (optional FR-BIF) on the servo amplifier
output side.
To avoid a malfunction, connect the wires to the correct phase terminals (U/V/W) of the servo amplifier
and servo motor.
Connect the servo amplifier power output (U/V/W) to the servo motor power input (U/V/W) directly. Do
not let a magnetic contactor, etc. intervene. Otherwise, it may cause a malfunction.
U
Servo motor
M
V
W
U
V
W
U
M
V
W
U
V
W
Servo amplifier
Servo motorServo amplifier
The connection diagrams in this instruction manual are shown for sink interfaces, unless stated
otherwise.
The surge absorbing diode installed to the DC relay for control output should be fitted in the specified
direction. Otherwise, the emergency stop and other protective circuits may not operate.
DOCOM
Control output
signal
Servo amplifier
RA
For sink output interface
24 V DC
DOCOM
Control output
signal
24 V DC
Servo amplifie
r
RA
For source output interface
When the cable is not tightened enough to the terminal block, the cable or terminal block may generate
heat because of the poor contact. Be sure to tighten the cable with specified torque.
Connecting a servo motor of the wrong axis to U, V, W, or CN2 of the servo amplifier may cause a
malfunction.
Configure a circuit to turn off EM2 or EM1 when the power supply is turned off to prevent an unexpected
restart of the servo amplifier.
To prevent malfunction, avoid bundling power lines (input/output) and signal cables together or running
them in parallel to each other. Separate the power lines from the signal cables.
(3) Test run and adjustment
CAUTION
When executing a test run, follow the notice and procedures in this instruction manual. Otherwise, it may
cause a malfunction, damage to the machine, or injury.
Before operation, check the parameter settings. Improper settings may cause some machines to operate
unexpectedly.
A - 5
CAUTION
Never adjust or change the parameter values extremely as it will make operation unstable.
Do not get close to moving parts during the servo-on status.
(4) Usage
CAUTION
When it is assumed that a hazardous condition may occur due to a power failure or product malfunction,
use a servo motor with an external brake to prevent the condition.
For equipment in which the moving part of the machine may collide against the load side, install a limit
switch or stopper to the end of the moving part. The machine may be damaged due to a collision.
Do not disassemble, repair, or modify the product. Otherwise, an electric shock, fire, injury, etc. may
occur. Disassembled, repaired, and/or modified products are not covered under warranty.
Before resetting an alarm, make sure that the run signal of the servo amplifier is off in order to prevent a
sudden restart. Otherwise, it may cause an accident.
Use a noise filter, etc. to minimize the influence of electromagnetic interference. Electromagnetic
interference may be given to the electronic equipment used near the servo amplifier.
Burning or breaking a servo amplifier may cause a toxic gas. Do not burn or break it.
Use the servo amplifier with the specified servo motor.
Correctly wire options and peripheral equipment, etc. in the correct combination. Otherwise, an electric
shock, fire, injury, etc. may occur.
The electromagnetic brake on the servo motor is designed to hold the motor shaft and should not be
used for ordinary braking.
For such reasons as incorrect wiring, service life, and mechanical structure (e.g. where a ball screw and
the servo motor are coupled via a timing belt), the electromagnetic brake may not hold the motor shaft.
To ensure safety, install a stopper on the machine side.
If the dynamic brake is activated at power-off, alarm occurrence, etc., do not rotate the servo motor by an
external force. Otherwise, it may cause a fire.
(5) Corrective actions
CAUTION
Ensure safety by confirming the power off, etc. before performing corrective actions. Otherwise, it may
cause an accident.
If it is assumed that a power failure, machine stoppage, or product malfunction may result in a hazardous
situation, use a servo motor with an electromagnetic brake or provide an external brake system for
holding purpose to prevent such hazard.
When any alarm has occurred, eliminate its cause, ensure safety, and deactivate the alarm before
restarting operation.
If the molded-case circuit breaker or fuse is activated, be sure to remove the cause and secure safety
before switching the power on. If necessary, replace the servo amplifier and recheck the wiring.
Otherwise, it may cause smoke, fire, or an electric shock.
Provide an adequate protection to prevent unexpected restart after an instantaneous power failure.
A - 6
CAUTION
Configure an electromagnetic brake circuit which is interlocked with an external emergency stop switch.
Servo motor
Electromagnetic brake
B
RA
Contacts must be opened
with the emergency stop switch.
Contacts must be opened when ALM
(Malfunction) or MBR (Electromagnetic
brake interlock) turns off.
24 V DC
U
To prevent an electric shock, injury, or fire from occurring after an earthquake or other natural disasters,
ensure safety by checking conditions, such as the installation, mounting, wiring, and equipment before
switching the power on.
(6) Maintenance, inspection and parts replacement
CAUTION
Make sure that the emergency stop circuit operates properly such that an operation can be stopped
immediately and a power is shut off by the emergency stop switch.
It is recommended that the servo amplifier be replaced every 10 years when it is used in general
environment.
When using a servo amplifier whose power has not been turned on for a long time, contact your local
sales office.
(7) General instruction
To illustrate details, the equipment in the diagrams of this Instruction Manual may have been drawn
without covers and safety guards. When the equipment is operated, the covers and safety guards must
be installed as specified. Operation must be performed in accordance with this Instruction Manual.
A - 7
DISPOSAL OF WASTE
Please dispose a servo amplifier and other options according to your local laws and regulations.
EEP-ROM life
The number of write times to the EEP-ROM, which stores parameter settings, etc., is limited to 100,000. If
the total number of the following operations exceeds 100,000, the servo amplifier may malfunction when the
EEP-ROM reaches the end of its useful life.
Write to the EEP-ROM due to parameter setting changes
Write to the EEP-ROM due to device changes
Compliance with global standards
Refer to app. 2 for the compliance with global standard.
Using HF-KN series and HF-SN series servo motors
For the combinations and characteristics when using HF-KN series and HF-SN series servo motors, refer to
app. 5.
«About the manual»
You must have this Instruction Manual and the following manuals to use this servo. Ensure to prepare
them to use the servo safely.
Relevant manuals
Manual name Manual No.
MELSERVO-JE Servo Amplifier Instruction Manual (Troubleshooting) SH(NA)030166ENG
MELSERVO MR-JE-_A Servo Amplifier Instruction Manual (Positioning Mode) SH(NA)030150ENG
MELSERVO MR-JE-_A Servo Amplifier Instruction Manual (Modbus RTU Protocol) SH(NA)030177ENG
MELSERVO HG-KN/HG-SN Servo Motor Instruction Manual SH(NA)030135ENG
MELSERVO EMC Installation Guidelines IB(NA)67310ENG
«Cables used for wiring»
Wires mentioned in this Instruction Manual are selected based on the ambient temperature of 40 °C.
«U.S. customary units»
U.S. customary units are not shown in this manual. Convert the values if necessary according to the
following table.
Quantity SI (metric) unit U.S. customary unit
Mass 1 [kg] 2.2046 [lb]
Length 1 [mm] 0.03937 [inch]
Torque 1 [N•m] 141.6 [oz•inch]
Moment of inertia 1 [(× 10
-4
kg•m
2
)] 5.4675 [oz•inch
2
]
Load (thrust load/axial load) 1 [N] 0.2248 [lbf]
Temperature N [°C] × 9/5 + 32 N [°F]
A - 8
MEMO
1
CONTENTS
1. FUNCTIONS AND CONFIGURATION 1- 1 to 1-14
1.1 Summary ........................................................................................................................................... 1- 1
1.2 Function block diagram ..................................................................................................................... 1- 2
1.3 Servo amplifier standard specifications ............................................................................................ 1- 4
1.4 Combinations of servo amplifiers and servo motors ........................................................................ 1- 6
1.5 Function list ....................................................................................................................................... 1- 7
1.6 Model designation ............................................................................................................................. 1- 9
1.7 Structure .......................................................................................................................................... 1-10
1.7.1 Parts identification ..................................................................................................................... 1-10
1.8 Configuration including peripheral equipment ................................................................................. 1-12
2. INSTALLATION 2- 1 to 2- 6
2.1 Installation direction and clearances ................................................................................................ 2- 2
2.2 Keep out foreign materials ................................................................................................................ 2- 3
2.3 Encoder cable stress ........................................................................................................................ 2- 4
2.4 Inspection items ................................................................................................................................ 2- 4
2.5 Parts having service life .................................................................................................................... 2- 5
2.6 Restrictions when using this product at altitude exceeding 1000 m and up to 2000 m
above sea level ................................................................................................................................. 2- 6
3. SIGNALS AND WIRING 3- 1 to 3-66
3.1 Input power supply circuit ................................................................................................................. 3- 2
3.2 I/O signal connection example .......................................................................................................... 3- 7
3.2.1 Position control mode ................................................................................................................. 3- 7
3.2.2 Speed control mode .................................................................................................................. 3-12
3.2.3 Torque control mode ................................................................................................................. 3-14
3.3 Explanation of power supply system ............................................................................................... 3-16
3.3.1 Signal explanations ................................................................................................................... 3-16
3.3.2 Power-on sequence .................................................................................................................. 3-17
3.3.3 Wiring CNP1 and CNP2 ............................................................................................................ 3-18
3.4 Connectors and pin assignment ...................................................................................................... 3-20
3.5 Signal (device) explanations ............................................................................................................ 3-23
3.6 Detailed explanation of signals ........................................................................................................ 3-32
3.6.1 Position control mode ................................................................................................................ 3-32
3.6.2 Speed control mode .................................................................................................................. 3-37
3.6.3 Torque control mode ................................................................................................................. 3-39
3.6.4 Position/speed control switching mode ..................................................................................... 3-42
3.6.5 Speed/torque control switching mode ....................................................................................... 3-44
3.6.6 Torque/position control switching mode.................................................................................... 3-46
3.7 Forced stop deceleration function ................................................................................................... 3-47
3.7.1 Forced stop deceleration function ............................................................................................. 3-47
3.7.2 Base circuit shut-off delay time function ................................................................................... 3-49
3.7.3 Vertical axis freefall prevention function ................................................................................... 3-50
3.7.4 Residual risks of the forced stop function (EM2) ...................................................................... 3-50
3.8 Alarm occurrence timing chart ......................................................................................................... 3-51
3.8.1 When you use the forced stop deceleration function ................................................................ 3-51
2
3.8.2 When you do not use the forced stop deceleration function ..................................................... 3-52
3.9 Interfaces ......................................................................................................................................... 3-53
3.9.1 Internal connection diagram ...................................................................................................... 3-53
3.9.2 Detailed explanation of interfaces ............................................................................................. 3-55
3.9.3 Source I/O interfaces ................................................................................................................ 3-59
3.10 Servo motor with an electromagnetic brake .................................................................................. 3-61
3.10.1 Safety precautions .................................................................................................................. 3-61
3.10.2 Timing chart ............................................................................................................................ 3-63
3.11 Grounding ...................................................................................................................................... 3-66
4. STARTUP 4- 1 to 4-38
4.1 Switching power on for the first time ................................................................................................. 4- 2
4.1.1 Startup procedure ...................................................................................................................... 4- 2
4.1.2 Wiring check ............................................................................................................................... 4- 3
4.1.3 Surrounding environment ........................................................................................................... 4- 4
4.2 Startup in position control mode ....................................................................................................... 4- 5
4.2.1 Power on and off procedures ..................................................................................................... 4- 5
4.2.2 Stop ............................................................................................................................................ 4- 5
4.2.3 Test operation ............................................................................................................................ 4- 6
4.2.4 Parameter setting ....................................................................................................................... 4- 7
4.2.5 Actual operation ......................................................................................................................... 4- 7
4.2.6 Trouble at start-up ...................................................................................................................... 4- 8
4.3 Startup in speed control mode ......................................................................................................... 4-10
4.3.1 Power on and off procedures .................................................................................................... 4-10
4.3.2 Stop ........................................................................................................................................... 4-10
4.3.3 Test operation ........................................................................................................................... 4-11
4.3.4 Parameter setting ...................................................................................................................... 4-12
4.3.5 Actual operation ........................................................................................................................ 4-13
4.3.6 Trouble at start-up ..................................................................................................................... 4-13
4.4 Startup in torque control mode ........................................................................................................ 4-14
4.4.1 Power on and off procedures .................................................................................................... 4-14
4.4.2 Stop ........................................................................................................................................... 4-14
4.4.3 Test operation ........................................................................................................................... 4-15
4.4.4 Parameter setting ...................................................................................................................... 4-16
4.4.5 Actual operation ........................................................................................................................ 4-16
4.4.6 Trouble at start-up ..................................................................................................................... 4-17
4.5 Display and operation sections ........................................................................................................ 4-18
4.5.1 Summary ................................................................................................................................... 4-18
4.5.2 Dis
play flowchart ....................................................................................................................... 4-19
4.5.3 Status display mode .................................................................................................................. 4-20
4.5.4 Diagnostic mode ....................................................................................................................... 4-24
4.5.5 Alarm mode ............................................................................................................................... 4-26
4.5.6 Parameter mode ....................................................................................................................... 4-27
4.5.7 External I/O signal display ......................................................................................................... 4-29
4.5.8 Output signal (DO) forced output .............................................................................................. 4-32
4.5.9 Test operation mode ................................................................................................................. 4-33
5. PARAMETERS 5- 1 to 5-48
5.1 Parameter list .................................................................................................................................... 5- 1
3
5.1.1 Basic setting parameters ([Pr. PA_ _ ]) ...................................................................................... 5- 2
5.1.2 Gain/filter setting parameters ([Pr. PB_ _ ]) ............................................................................... 5- 2
5.1.3 Extension setting parameters ([Pr. PC_ _ ]) .............................................................................. 5- 4
5.1.4 I/O setting parameters ([Pr. PD_ _ ]) ......................................................................................... 5- 5
5.1.5 Extension setting 2 parameters ([Pr. PE_ _ ]) ............................................................................ 5- 6
5.1.6 Extension setting 3 parameters ([Pr. PF_ _ ]) ............................................................................ 5- 8
5.2 Detailed list of parameters ................................................................................................................ 5- 9
5.2.1 Basic setting parameters ([Pr. PA_ _ ]) ...................................................................................... 5- 9
5.2.2 Gain/filter setting parameters ([Pr. PB_ _ ]) .............................................................................. 5-17
5.2.3 Extension setting parameters ([Pr. PC_ _ ]) ............................................................................. 5-29
5.2.4 I/O setting parameters ([Pr. PD_ _ ]) ........................................................................................ 5-40
5.2.5 Extension setting 2 parameters ([Pr. PE_ _ ]) ........................................................................... 5-45
5.2.6 Extension setting 3 parameters ([Pr. PF_ _ ]) ........................................................................... 5-46
6. NORMAL GAIN ADJUSTMENT 6- 1 to 6-34
6.1 Different adjustment methods ........................................................................................................... 6- 1
6.1.1 Adjustment on a single servo amplifier ...................................................................................... 6- 1
6.1.2 Adjustment using MR Configurator2 .......................................................................................... 6- 2
6.2 One-touch tuning .............................................................................................................................. 6- 3
6.2.1 One-touch tuning flowchart ........................................................................................................ 6- 5
6.2.2 Display transition and operation procedure of one-touch tuning ............................................... 6- 8
6.2.3 Caution for one-touch tuning ..................................................................................................... 6-23
6.3 Auto tuning ....................................................................................................................................... 6-24
6.3.1 Auto tuning mode ...................................................................................................................... 6-24
6.3.2 Auto tuning mode basis ............................................................................................................. 6-25
6.3.3 Adjustment procedure by auto tuning ....................................................................................... 6-26
6.3.4 Response level setting in auto tuning mode ............................................................................. 6-27
6.4 Manual mode ................................................................................................................................... 6-28
6.5 2 gain adjustment mode .................................................................................................................. 6-32
7. SPECIAL ADJUSTMENT FUNCTIONS 7- 1 to 7-30
7.1 Filter setting ...................................................................................................................................... 7- 1
7.1.1 Machine resonance suppression filter ....................................................................................... 7- 1
7.1.2 Adaptive filter II ........................................................................................................................... 7- 4
7.1.3 Shaft resonance suppression filter ............................................................................................. 7- 7
7.1.4 Low-pass filter ............................................................................................................................ 7- 8
7.1.5 Advanced vibration suppression control II ................................................................................. 7- 8
7.1.6 Command notch filter ................................................................................................................ 7-13
7.2 Gain switching function .................................................................................................................... 7-14
7.2.1 Applications ............................................................................................................................... 7-14
7.2.2 Function block diagram ............................................................................................................. 7-15
7.2.3 Parameter .................................................................................................................................. 7-16
7.2.4 Gain switching procedure ......................................................................................................... 7-18
7.3 Tough drive function ........................................................................................................................ 7-22
7.3.1 Vibration tough drive function.................................................................................................... 7-22
7.3.2 Instantaneous power failure tough drive function ..................................................................... 7-24
7.4 Model adaptive control disabled ...................................................................................................... 7-27
7.5 Lost motion compensation function ................................................................................................. 7-28
4
8. TROUBLESHOOTING 8- 1 to 8- 8
8.1 Explanations of the lists .................................................................................................................... 8- 1
8.2 Alarm list ........................................................................................................................................... 8- 2
8.3 Warning list ....................................................................................................................................... 8- 6
9. DIMENSIONS 9- 1 to 9- 6
9.1 Servo amplifier .................................................................................................................................. 9- 1
9.2 Connector ......................................................................................................................................... 9- 4
10. CHARACTERISTICS 10- 1 to 10- 8
10.1 Overload protection characteristics .............................................................................................. 10- 1
10.2 Power supply capacity and generated loss .................................................................................. 10- 2
10.3 Dynamic brake characteristics ...................................................................................................... 10- 4
10.3.1 Dynamic brake operation ....................................................................................................... 10- 5
10.3.2 Permissible load to motor inertia when the dynamic brake is used ....................................... 10- 6
10.4 Cable bending life ......................................................................................................................... 10- 6
10.5 Inrush current at power-on ........................................................................................................... 10- 7
11. OPTIONS AND PERIPHERAL EQUIPMENT 11- 1 to 11-32
11.1 Cable/connector sets .................................................................................................................... 11- 1
11.1.1 Combinations of cable/connector sets ................................................................................... 11- 2
11.2 Regenerative option ...................................................................................................................... 11- 4
11.2.1 Combination and regenerative power .................................................................................... 11- 4
11.2.2 Selection of regenerative option ............................................................................................ 11- 5
11.2.3 Parameter setting ................................................................................................................... 11- 6
11.2.4 Connection of regenerative option ......................................................................................... 11- 7
11.2.5 Dimensions ........................................................................................................................... 11-11
11.3 Junction terminal block MR-TB50 ................................................................................................ 11-13
11.4 MR Configurator2 ........................................................................................................................ 11-15
11.4.1 Specifications ........................................................................................................................ 11-15
11.4.2 System requirements ............................................................................................................ 11-16
11.4.3 Precautions for using USB communication function ............................................................. 11-17
11.5 Selection example of wires .......................................................................................................... 11-18
11.6 Molded-case circuit breakers, fuses, magnetic contactors ......................................................... 11-19
11.7 Power factor improving AC reactor .............................................................................................. 11-20
11.8 Relay (recommended) ................................................................................................................. 11-21
11.9 Noise reduction techniques ......................................................................................................... 11-22
11.10 Earth-leakage current breaker ................................................................................................... 11-28
11.11 EMC filter (recommended) ........................................................................................................ 11-30
12. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL) 12- 1 to 12-34
12.1 Structure ....................................................................................................................................... 12- 1
12.1.1 Configuration diagram ............................................................................................................ 12- 1
12.1.2 Precautions for using RS422/USB communication function .................................................. 12- 2
5
12.2 Communication specifications ...................................................................................................... 12- 3
12.2.1 Outline of communication ...................................................................................................... 12- 3
12.2.2 Parameter setting ................................................................................................................... 12- 3
12.3 Protocol ......................................................................................................................................... 12- 4
12.3.1 Transmission data configuration ............................................................................................ 12- 4
12.3.2 Character codes ..................................................................................................................... 12- 5
12.3.3 Error codes ............................................................................................................................. 12- 6
12.3.4 Checksum .............................................................................................................................. 12- 6
12.3.5 Time-out processing............................................................................................................... 12- 6
12.3.6 Retry processing .................................................................................................................... 12- 7
12.3.7 Initialization ............................................................................................................................ 12- 7
12.3.8 Communication procedure example ...................................................................................... 12- 8
12.4 Command and data No. list .......................................................................................................... 12- 9
12.4.1 Reading command ................................................................................................................. 12- 9
12.4.2 Writing commands ................................................................................................................ 12-13
12.5 Detailed explanations of commands ............................................................................................ 12-15
12.5.1 Data processing .................................................................................................................... 12-15
12.5.2 Status display mode .............................................................................................................. 12-17
12.5.3 Parameter ............................................................................................................................. 12-18
12.5.4 External I/O signal status (DIO diagnosis) ............................................................................ 12-22
12.5.5 Input device on/off ................................................................................................................. 12-25
12.5.6 Disabling/enabling I/O devices (DIO) .................................................................................... 12-25
12.5.7 Input devices on/off (test operation) ...................................................................................... 12-26
12.5.8 Test operation mode ............................................................................................................. 12-27
12.5.9 Output signal pin on/off (output signal (DO) forced output) .................................................. 12-30
12.5.10 Alarm history ....................................................................................................................... 12-31
12.5.11 Current alarm ...................................................................................................................... 12-32
12.5.12 Software version ................................................................................................................. 12-33
APPENDIX App. - 1 to App. -22
App. 1 Peripheral equipment manufacturer (for reference) .............................................................. App.- 1
App. 2 Compliance with global standards ........................................................................................ App.- 1
App. 3 Analog monitor ..................................................................................................................... App.-12
App. 4 Low-voltage directive ........................................................................................................... App.-15
App. 5 Using HF-KN series and HF-SN series servo motors ......................................................... App.-16
App. 6 When turning on or off the input power supply with DC power supply ................................ App.-18
App. 7 Using the neutral point of a 3-phase 400 V AC class power supply for inputting a
1-phase 200 V AC class power supply ................................................................................ App.-19
App. 8 Status of general-purpose AC servo products for compliance with the China RoHS
directive ................................................................................................................................ App.-21
6
MEMO
1. FUNCTIONS AND CONFIGURATION
1 - 1
1. FUNCTIONS AND CONFIGURATION
1.1 Summary
The Mitsubishi Electric general-purpose AC servo MELSERVO-JE series have limited functions with keeping
high performance based on MELSERVO-J4 series.
The servo amplifier has position, speed, and torque control modes. In the position control mode, the
maximum pulse train of 4 Mpulses/s is supported. Further, it can perform operation with the control modes
switched, e.g. position/speed control, speed/torque control and torque/position control. Hence, it is
applicable to a wide range of fields, not only precision positioning and smooth speed control of machine tools
and general industrial machines but also line control and tension control.
With one-touch tuning and real-time auto tuning, you can automatically adjust the servo gains according to
the machine.
The tough drive function, drive recorder function, and preventive maintenance support function strongly
support machine maintenance.
The servo amplifier has a USB communication interface. Therefore, you can connect the servo amplifier to
the personal computer with MR Configurator2 installed to perform the parameter setting, test operation, gain
adjustment, and others.
The MELSERVO-JE series servo motor equipped with an incremental encoder whose resolution is 131072
pulses/rev will enable a high-accuracy positioning.
1. FUNCTIONS AND CONFIGURATION
1 - 2
1.2 Function block diagram
The function block diagram of this servo is shown below.
(1) MR-JE-100A or less
Model position
Current
control
Actual
position
control
Actual
speed
control
Virtual
motor
Virtual
encoder
Encoder
(Note 2)
Power
supply
MCMCCB
Position
command
input
Model speed Model torque
CN2
Model
position
control
Model
speed
control
Servo motor
U U
U
C
L3
L2
L1
Dynamic
brake circuit
Current
detection
Overcurrent
protection
Voltage
detection
Base
amplifier
U
V
W
U
V
W
Diode
stack
Relay
P+
(Note 1)
+
B
RA
24 V DC
B1
B2
M
Control
circuit
power
CHARGE
lamp
Regene-
rative
TR
Current
encoder
Regenerative
option
Electromagnetic
brake
CN3
Analog monitor
(2 channels)
I/F
USBA/D D/A
USB
Personal
computer
Analog
(2 channels)
Servo-on
Input command pulse.
Start
Malfunction, etc.
CN1
RS-422/
RS-485
Controller
RS-422/
RS-485
D I/O control
Note 1. The built-in regenerative resistor is not provided for MR-JE-10A and MR-JE-20A.
2. For 1-phase 200 V AC to 240 V AC, connect the power supply to L1 and L3. Leave L2 open.
For the power supply specifications, refer to section 1.3.
1. FUNCTIONS AND CONFIGURATION
1 - 3
(2) MR-JE-200A or more
MCMCCB
Servo motor
U U
U
L3
L2
L1
U
V
W
U
V
W
B
RA
24 V DC
B1
B2
M
CN2
CDP+
+
Cooling fan
(Note)
Power
supply
Dynamic
brake circuit
Diode
stack
Relay
CHARGE
lamp
Regene-
rative
TR
Current
encoder
Regenerative
option
Encoder
Current
detection
Overcurrent
protection
Voltage
detection
Base
amplifier
Control
circuit
power
Electromagnetic
brake
Model position
Current
control
Actual
position
control
Actual
speed
control
Virtual
motor
Virtual
encoder
Position
command
input
Model speed Model torque
Model
position
control
Model
speed
control
CN3
Analog monitor
(2 channels)
I/F
USBA/D D/A
USB
Personal
computer
Analog
(2 channels)
CN1
Servo-on
Input command pulse.
Start
Malfunction, etc.
D I/O control
RS-422/
RS-485
Controller
RS-422/
RS-485
Note. For the power supply specifications, refer to section 1.3.
1. FUNCTIONS AND CONFIGURATION
1 - 4
1.3 Servo amplifier standard specifications
Model: MR-JE- 10A 20A 40A 70A 100A 200A 300A
Output
Rated voltage 3-phase 170 V AC
Rated current [A] 1.1 1.5 2.8 5.8 6.0 11.0 11.0
Power supply
input
Voltage/Frequency
3-phase or 1-phase 200 V AC to 240 V AC, 50
Hz/60 Hz
3-phase or 1-phase
200 V AC to 240 V AC,
50 Hz/60 Hz (Note 6)
3-phase
200 V AC to
240 V AC,
50 Hz/60 Hz
Rated current
(Note 5)
[A]
0.9 1.5 2.6 3.8 5.0 10.5 14.0
Permissible voltage
fluctuation
3-phase or 1-phase 170 V AC to 264 V AC
3-phase or 1-phase
170 V AC to 264 V AC
(Note 6)
3-phase
170 V AC to
264 V AC
Permissible frequency
fluctuation
Within ±5%
Power supply capacity
[kVA]
Refer to section 10.2.
Inrush current [A] Refer to section 10.5.
Interface
power supply
Voltage 24 V DC ± 10%
Current capacity [A] 0.3 (Note 1)
Control method Sine-wave PWM control, current control method
Dynamic brake Built-in
Communication function
USB: connection to a personal computer or others (MR Configurator2-compatible)
RS-422/RS-485: Connection to controller (1: n communication up to 32 axes) (Note 4, 7)
Encoder output pulses Compatible (A/B/Z-phase pulse)
Analog monitor Two channels
Position
control mode
Max. input pulse
frequency
4 Mpulses/s (for differential receiver) (Note 3), 200 kpulses/s (for open collector)
Positioning feedback
pulse
Encoder resolution (resolution per servo motor revolution): 131072 pulses/rev
Command pulse
multiplying factor
Electronic gear A:1 to 16777215, B:1 to 16777215, 1/10 < A/B < 4000
In-position range
setting
0 pulse to ±65535 pulses (command pulse unit)
Error excessive ±3 revolutions
Torque limit Set by parameter setting or external analog input (0 V DC to +10 V DC/maximum torque)
Speed control
mode
Speed control range Analog speed command 1: 2000, internal speed command 1: 5000
Analog speed
command input
0 to ±10 V DC/rated speed (The speed at 10 V is changeable with [Pr. PC12].)
Speed fluctuation ratio
±0.01% or less (load fluctuation 0% to 100%), 0% (power fluctuation ±10%), ±0.2% or less
(ambient temperature 25 °C ± 10 °C) when using analog speed command
Torque limit Set by parameter setting or external analog input (0 V DC to +10 V DC/maximum torque)
Torque
control mode
Analog torque
command input
0 V DC to ±8 V DC/maximum torque (input impedance 10 kΩ to 12 kΩ)
Speed limit Set by parameter setting or external analog input (0 V DC to 10 V DC/rated speed)
Positioning mode
Refer to section 1.1 of "MR-JE-_A Servo Amplifier Instruction Manual (Positioning Mode)"
The positioning mode is available with servo amplifiers with software version B7 or later.
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal),
servo motor overheat protection, encoder error protection, regenerative error protection,
undervoltage protection, instantaneous power failure protection, overspeed protection, and
error excessive protection
Compliance
with global
standards
CE marking
LVD: EN 61800-5-1
EMC: EN 61800-3
UL standard UL 508C
Structure (IP rating) Natural cooling, open (IP20)
Force cooling, open
(IP20)
Close
mounting
(Note 2)
3-phase power supply
input
Possible
1-phase power supply
input
Possible Impossible
1. FUNCTIONS AND CONFIGURATION
1 - 5
Model: MR-JE- 10A 20A 40A 70A 100A 200A 300A
Environment
Ambient
temperature
Operation 0 °C to 55 °C (non-freezing)
Storage -20 °C to 65 °C (non-freezing)
Ambient
humidity
Operation
5 %RH to 90 %RH (non-condensing)
Storage
Ambience
Indoors (no direct sunlight),
free from corrosive gas, flammable gas, oil mist, dust, and dirt
Altitude 2000 m or less above sea level (Note 8)
Vibration resistance 5.9 m/s
2
, at 10 Hz to 55 Hz (directions of X, Y and Z axes)
Mass [kg] 0.8 1.5 2.1
Note 1. 0.3 A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2. When closely mounting the servo amplifier of 3.5 kW or less, operate them at the ambient temperatures of 0 °C to 45 °C or at
75% or smaller effective load ratio.
3. 1 Mpulse/s or lower commands are supported in the initial setting. When inputting commands over 1 Mpulse/s and 4 Mpulses/
s
or lower, change the setting in [Pr. PA13].
4. The RS-422 communication function is supported by servo amplifier manufactured in December 2013 or later. Refer to section
1.6 (1) for the year and month of manufacture.
5. These are current values for 3-phase power supply.
6. When using 1-phase 200 V AC to 240 V AC power supply, operate the servo amplifier at 75% or smaller effective load ratio.
7. The RS-485 communication function is available with servo amplifiers manufactured in May 2015 or later. Refer to section 1.6
(1) for the year and month of manufacture.
8. Follow the restrictions in section 2.6 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level.
/