Optional Accessories
Quick Start Guide
14
Warning: Shock Hazard
Testbetweenallterminalsand
groundbeforetouching.
PoweroraccessoryterminalsareNOT
electricallyisolatedfromDCinputandmay
be energized with hazardous
solar voltage.
Switch 1: Load/Lighting
Switches 2 & 3: System Voltage
Specifications:
Switches 4, 5, & 6: Battery Type Selection
Switch 7: Battery Equalization
Switch 8: Current Switching
Operational Configuration:
Lighting
Normal
PS‐15/PS‐15M
NominalBatteryVoltage 12/24V
Max.PVOpen‐CircuitVoltage 30/60V
MaximumInputCurrent 15A
RatedLoadCurrent 15A
PS‐30/PS‐30M
12/24V
30/60V
30A
30A
©2020MorningstarCorporation.AllRightsReserved.
In the box:
Tools Required:
— #2PhilipsScrewdriver
— 3/16(5mm)&3/32"(2.5mm)FlatheadScrewdriver
RelayDriver(RD‐1)
RemoteMeter(RM‐1)
EthernetMeterBus
Converter(EMC‐1)
Safety Information:
Warning: Shock Hazard
TheProStarGen3controllermustbeinstalledbya
qualifiedtechnicianinaccordancewiththeelectrical
regulationsofthecountryofinstallation.
Warning: Shock Hazard
ThisunitisnotprovidedwithaGFDIdevice.Thischarge
controllermustbeusedwithanexternalGFDIdeviceas
requiredbytheArticle690oftheNationalElectricalCode
fortheinstallationlocation.
IMPORTANT: READtheProStarGen3Installation
Manualforsafetyandregulatoryinformation,
instructionsonconfiguration
andoperation,and
warrantyinformation.
PVGroundFaultProtection
(GFPD‐150VandGFPD‐600V)
RemoteTemperature
Sensor(RTS)
Scan QR Code to go
directly to the
ProStar Gen3
Installation Manual
and warranty
information online.
Contact Information:
TechnicalSupport:Support.morningstarcorp.com
Phone:1‐215‐321‐4457
AUTO 12V
24V
ManualEQ AutoEQ
ProStarChargeController
SlowSwitchingPWMSwitching
SystemVoltage Switch2
Auto OFF
12 OFF
Switch3
OFF
ON
24 ON OFF
Mode Switch1
Normal OFF
Lighting ON
Mode Switch8
PWMSwitching OFF
SlowSwitching ON
1–Sealed*3–Sealed*
4–AGM/
Flooded*
5–Flooded 6–Flooded 7–L‐162–Sealed* Custom**
Mode Switch7
ManualEqualization OFF
Auto‐Equalization ON
WarrantyRegistration:https://www.morningstarcorp.com/product‐registration/
FloatCancelVoltage
12.10Volts
FloatExitTime‐Out 30minutes
AbsorptionExtensionTime AbsorptionTime+30minutes
AbsorptionExtensionVoltage
12.50Volts
SharedSettings SetPoint
SharedSettings SetPoint
TemperatureCompensationCo‐Efficient –30millivolts/°C/12Volts
EqualizeTime‐Out EqualizeTime+60minutes
DIPSwitch
Setting
BatteryType
Absorption
Stage
(Volts)
Float
State
(Volts)
Equalize
Stage
(Volts)
Absorption
Time
(Minutes)
Equalize
Time
(Minutes)
Equalize
Timeout
(Minutes)
Equalize
Interval
(days)
LVD
(Volts)
LVR
Volts)
4 5 6
OFF OFF OFF 1–Sealed* 14.00 13.50 ‐‐‐ 150 ‐‐‐ ‐‐‐ ‐‐‐ 11.5 12.6
OFF OFF ON 2–Sealed* 14.15 13.50 14.40 150 60 120 28 11.5 12.6
OFF ON OFF 3–Sealed* 14.30 13.50 14.60 150 60 120 28 11.5 12.6
OFF ON ON 4–AGM/Flooded* 14.40 13.50 15.10 180 120 180 28 11.5 12.6
ON OFF OFF 5–Flooded 14.60 13.50 15.30 180 120 180 28 11.5 12.6
ON OFF ON 6–Flooded 14.70 13.50 15.40 180 180 240 28 11.5 12.6
ON ON OFF 7–L‐16 15.40 13.40 16.00 180 180 240 14 11.5 12.6
ON ON ON 8–Custom**
Custom Custom Custom Custom Custom Custom Custom Custom Custom
*“Sealed”batterytypesincludeGelandAGMBatteries
**Lithium‐ionandsomeotherbatterytypesrequirecustomprogramming.Morningstarprovidesdownloadablesettingsforselectedbattery
manufacturershere:https://www.morningstarcorp.com/energy‐storage‐partner‐program/
NOTE:TheProStarGen3canbeprogrammedtoaccommodateawiderangeofchargingparameters.
Consultthebatterymanufacturerforoptimalbatterychargingsettings.
ToChangeSettings:
•Onmeteredmodels,usetheinterfaceonthemeterorusethesoftwareavailableathttps://www.morningstarcorp.com/msview/.
•Onnon‐meteredmodels,usethesoftwareavailableathttps://www.morningstarcorp.com/msview/.
SeetheProStarInstallation,Operations,andMaintenanceManualforadditionalinformation/guidance.
Meteredversionshown.
PCMeterBusAdapter
(MSC)
USBCommunicationsAdapter
(UMC‐1)
MenuMap(2pages)
Self‐Tapping
Mounting
Screws(x4)
MS‐001534revB