Morningstar ProStar Gen3 User guide

Type
User guide

This manual is also suitable for

Optional Accessories
Quick Start Guide
14
Warning: Shock Hazard
Testbetweenallterminalsand
groundbeforetouching.
PoweroraccessoryterminalsareNOT
electricallyisolatedfromDCinputandmay
be energized with hazardous
solar voltage.
Switch 1: Load/Lighting
Switches 2 & 3: System Voltage
Specifications:
Switches 4, 5, & 6: Battery Type Selection
Switch 7: Battery Equalization
Switch 8: Current Switching
Operational Configuration:
Lighting
Normal
PS15/PS15M
NominalBatteryVoltage 12/24V
Max.PVOpenCircuitVoltage 30/60V
MaximumInputCurrent 15A
RatedLoadCurrent 15A
PS30/PS30M
12/24V
30/60V
30A
30A
©2020MorningstarCorporation.AllRightsReserved.
In the box:
Tools Required:
#2PhilipsScrewdriver
3/16(5mm)&3/32"(2.5mm)FlatheadScrewdriver
RelayDriver(RD1)
RemoteMeter(RM1)
EthernetMeterBus
Converter(EMC1)
Safety Information:
Warning: Shock Hazard
TheProStarGen3controllermustbeinstalledbya
qualifiedtechnicianinaccordancewiththeelectrical
regulationsofthecountryofinstallation.
Warning: Shock Hazard
ThisunitisnotprovidedwithaGFDIdevice.Thischarge
controllermustbeusedwithanexternalGFDIdeviceas
requiredbytheArticle690oftheNationalElectricalCode
fortheinstallationlocation.
IMPORTANT: READtheProStarGen3Installation
Manualforsafetyandregulatoryinformation,
instructionsonconfiguration
andoperation,and
warrantyinformation.
PVGroundFaultProtection
(GFPD150VandGFPD600V)
RemoteTemperature
Sensor(RTS)
Scan QR Code to go
directly to the
ProStar Gen3
Installation Manual
and warranty
information online.
Contact Information:
TechnicalSupport:Support.morningstarcorp.com
Phone:12153214457
AUTO 12V
24V
ManualEQ AutoEQ
ProStarChargeController
SlowSwitchingPWMSwitching
SystemVoltage Switch2
Auto OFF
12 OFF
Switch3
OFF
ON
24 ON OFF
Mode Switch1
Normal OFF
Lighting ON
Mode Switch8
PWMSwitching OFF
SlowSwitching ON
1Sealed*3Sealed*
4AGM/
Flooded*
5Flooded 6Flooded 7L162Sealed* Custom**
Mode Switch7
ManualEqualization OFF
AutoEqualization ON
WarrantyRegistration:https://www.morningstarcorp.com/productregistration/
FloatCancelVoltage
12.10Volts
FloatExitTimeOut 30minutes
AbsorptionExtensionTime AbsorptionTime+30minutes
AbsorptionExtensionVoltage
12.50Volts
SharedSettings SetPoint
SharedSettings SetPoint
TemperatureCompensationCoEfficient –30millivolts/°C/12Volts
EqualizeTimeOut EqualizeTime+60minutes
DIPSwitch
Setting
BatteryType
Absorption
Stage
(Volts)
Float
State
(Volts)
Equalize
Stage
(Volts)
Absorption
Time
(Minutes)
Equalize
Time
(Minutes)
Equalize
Timeout
(Minutes)
Equalize
Interval
(days)
LVD
(Volts)
LVR
Volts)
4 5 6
OFF OFF OFF 1Sealed* 14.00 13.50 ‐‐‐ 150 ‐‐‐ ‐‐‐ ‐‐‐ 11.5 12.6
OFF OFFON 2Sealed* 14.15 13.50 14.40 150 60 120 28 11.5 12.6
OFFON OFF 3Sealed* 14.30 13.50 14.60 150 60 120 28 11.5 12.6
OFFON ON 4AGM/Flooded* 14.40 13.50 15.10 180 120 180 28 11.5 12.6
ONOFF OFF 5Flooded 14.60 13.50 15.30 180 120 180 28 11.5 12.6
ONOFFON 6Flooded 14.70 13.50 15.40 180 180 240 28 11.5 12.6
ON ONOFF 7L16 15.40 13.40 16.00 180 180 240 14 11.5 12.6
ON ON ON 8Custom**
Custom Custom Custom Custom Custom Custom Custom Custom Custom
*“Sealed”batterytypesincludeGelandAGMBatteries
**Lithiumionandsomeotherbatterytypesrequirecustomprogramming.Morningstarprovidesdownloadablesettingsforselectedbattery
manufacturershere:https://www.morningstarcorp.com/energystoragepartnerprogram/
NOTE:TheProStarGen3canbeprogrammedtoaccommodateawiderangeofchargingparameters.
Consultthebatterymanufacturerforoptimalbatterychargingsettings.
ToChangeSettings:
Onmeteredmodels,usetheinterfaceonthemeterorusethesoftwareavailableathttps://www.morningstarcorp.com/msview/.
Onnonmeteredmodels,usethesoftwareavailableathttps://www.morningstarcorp.com/msview/.
SeetheProStarInstallation,Operations,andMaintenanceManualforadditionalinformation/guidance.
Meteredversionshown.
PCMeterBusAdapter
(MSC)
USBCommunicationsAdapter
(UMC1)
MenuMap(2pages)
SelfTapping
Mounting
Screws(x4)
MS001534revB
DIP
ON
1 2
3
4 5 6 7 8
SENSE
BATTERY
SOLAR
RTS
LOAD
Charging
Status/
Error LED
Battery Status/
Fault LEDs
32
ProStar Gen3 Charge Controller
Quick Start Guide
6"(15cm)MAXIMUMDistance
fromBattery(+)Terminal
(+)
(–)
(+)
(–)
Solar Disconnect*
(PV GFP required per
NEC 690)
Photovoltaic (PV) Array
Battery / Battery Bank
Battery Disconnect*
*Fuseorbreakersizingbased
onrequiredwireampacity
Fuse
Primary Ground
Electrode Conductor
(System Ground)
12345678
DIP Switch Block
(enlarged)
(SeePage4forsettings)
DCtoGround
Bond
Power UP Sequence:
1. ConnectBattery/BatteryBank.
2. ConnectSolar.
Power DOWN Sequence:
1. DisconnectSolar.
2. DisconnectBattery/BatteryBank.
Mounting:
#2
Minimum
Clearance
Requirements
Caution: Equipment Damage
DonotexposetheProStarCCtoweather.Locate
inadry,protectedareatopreventequipment
damage.Ensuretheminimumclearance
requirementsarefollowedtoprovideadequate
ventilationandpreventtheunitfromoverheating.
6"
6"
2"
IMPORTANT: Exampleonly.Actualwiringmayvary.READ
theProStarGen3Installation,Operations,andMaintenance
Manualformandatorysafetyrequirements.Allconfiguration
mustcomplywithlocalandnationalelectriccodes.Consultyour
localelectricauthoritytoensurecompliance.
Thisillustrationrepresentsatypicaloffgridinstallation.Foruse
withaninverter,
refertotheinverter’sinstallationmanualfor
additionalinformation.
Negative (–)
Positive (+)
Ground
LEGEND
SeetheMorningstarPVStringCalculatorat:
http://stringcalculator.morningstarcorp.com/
Component
PowerTerminals
WireSize
2.5‐16mm
2
/
#14‐6AWG
ToolRequired
3/16"(5mm)
FlatheadScrewdriver
BatteryVoltage
Sense
0.25‐1.0mm
2
/
#24‐16AWG
3/32"(2.5mm)
FlatheadScrewdriver
MountingScrews
‐‐‐ #2PhilipsScrewdriver
Wiring and Torque Requirements
Torque(Max)
35inlbs.(3.9Nm)
5inlbs.(0.56Nm)
5inlbs.(0.56Nm)
RemoteTemperature
Sensor
(included)
3/32"(2.5mm)
FlatheadScrewdriver
5inlbs.(0.56Nm)
Securinghardware
notshown.
DC Load
Disconnect*
Pushtabsoutwardto
releasetheterminalcover.
Pulltheterminalcover
forwardtoremoveit.
2"
Tightenthe4selftapping
screwsjustenoughto
holdtheProStarinplace.
1
2
3
RJ11
Cable
RelayDriver
Optional Accessories
RemoteMeter
EthernetMeterBus
Converter
PCMeterBusAdapter
(MSC)
USBCommunications
Adapter(UMC1)
Battery(–)
(—)VoltageSense
Conductor
(+)VoltageSense
Conductor
RemoteTemperature
SensorConductor
Battery(+)
IMPORTANT:
Ensurethereisonly 1
DCNegativetoGround
Bondintheentiresystem.
IMPORTANT:
Mountintheorientationshown
herewiththeheatsinkfins
vertical.
Top
Bottom
IMPORTANT:
DoNOTovertighten.
ON
1 2
3
4 5 6 7 8
SENSE
BATTERYSOLAR
RTS
LOAD
ON
1 2
3
4 5 6 7 8
SENSE
BATTERYSOLAR
RTS
LOAD
DC Load(s)*
Communications
Lighting
Industrial
Security
Residential
LEDIndicators:
SeetheProStarGen3
InstallationManualfordetails.