  • Hello! I am an AI chatbot trained to assist you with the Niigata seiki WCDI-10D/WCDI-18D User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ABS/SET
MIN CAL
ZERO/ON
ABS/SET
MIN CAL
ZERO/ON
ABS
mm
DIGITAL BORE GAUGE Model:WCDI-10D/WCDI-18D
combined
Instruction Manual
Accessories
Handle
Cap
Clamp
Screw
After attaching, press the [ZERO/
ON] Button on the Digital Indicator
to turn on power. Confirm that the
displayed reading changes by
gently squeezing the measurement
head. If necessary, adjust the
depth that the Digital Indicator is
inserted into the gauge body.
Select the Extension Rod, washer (WCDI-18Donly) for the desired
measurement range.
Loosen the Clamp Screw and
insert the Digital Indicator into
the gauge body. Tighten the
Clamp Screw to secure.
INSERT
Extension
Rod
Shaft
Length below Handle:
Measure-
ment Head
Probe Tip
Length below Handle:
Extension
Rod
Measurement
Head
Guide
Probe Tip
Spanner
Spanner
Nut
1.Use the Spanner to loosen
the Nut at the bottom of
Measurement Head.
2. Install the Extension Rod
and tighten.
Attach the Extension Rod,
Washer to the bottom of the
Measurement Head and tighten
with the Spanner.
Ex. Rod
Ex. Rod Washer
Ex.set to
Ex. set to
Extension Rods
pieces
pieces
Spanner x
Battery Lithium button cell, 1x (for test)
Washer
only
Extension Rod
Spanners shown in drawing
above vary slightly in appearance,
but function will be same.
Spanner
Not including quantization error (±1 count)
Thank you for purchasing the Digital Bore Gauge.
Please read this manual thoroughly before use for proper operation.
SPECIFICATIONS Including supplied Digital Gauge
PART IDENTIFICATION
Measuring Range
Resolution
Wide Range Acc'y
Adjacent Error
Repeat Accuracy
Single Stroke Range
Washer
Weight
Model No.
ACCESSORIES
Display
[]
Button
[] Button
[]Button
[]
Button
Clamp
Screw
Gauge
Digital Indicator
Not Used
"0.01" indicates the resolution
of the display's digital bar
graph. The bar graph display
will change with each 0.01mm
change in the measured
value.
This is a precision instrument, handle with care.
Do not disassemble or modify.
Keep instrument away from water and oil.
Use only with supplied Extension Rods and Washer.
Keep instrument away from direct sunlight and high temperatures
such as in a car, or near a stove or heat source.
After use, remove any dirt or cutting chips and apply rust preventative
oil to to Extension Rod and Washer. When not in use store in
supplied storage case.
This product is for measuring inside diameter; use only as directed.
Improper use may cause accident or injury.
Avoid using in high electric fields, such as near fluorescent lights or
switching power supplies.
Electrical interference may cause incorrect readings.
NOTICE
Pull out the case from the two side
edges to remove. Insert battery with
( ) side facing down.
Use only CR2032 type lithium button cell.
NOTICE
Battery
Case
Battery
INSERTING REPLACING BATTERY
ASSEMBLY
ABS/SET
MIN CAL
ZERO/ON
ABS
mm
ABS/SET
MIN CAL
ZERO/ON
ABS
mm 15.998
ABS/SET
MIN CAL
ZERO/ON
mm
ABS/SET
MIN CAL
ZERO/ON
ABS
mm
does not have a guide on the Measurement Head so please manually position at this maximum value.
MEASUREMENT
Fig. Fig. Fig.
For accurate measurements, follow the procedure described below.
In cross section perpendicular to the axis of the bore, as shown in Figure 1, position the gauge along diameter . This is the
maximum distance, and at this point the Indicator will read the maximum value. The Guide will automatically position the
Measurement Head to diameter when inserted.
In cross section parallel to to the axis of the bore through diameter , position the indicator to minimize the distance . (Figure 2)
In this position the Indicator will read the minimum value. This position must be manually determined by pivoting the Gauge as
shown in Figure 3 while watching the Indicator to find the minimum value.
OPERATION
Before use, please make sure the Measurement Head components are not loose and tighten if necessary.
Clean the Measurement Head and the ID of a Ring Gauge Standard using parts cleaner or cleaning solution.
Press the [ZERO/ON] Button to turn on power. A long press to the [ZERO/ON] Button will turn power off.
ABSOLUTE MODE (ABS)
Turn on power. If the “ ” or “
Measure absolute dimension of workpiece
” symbols are displayed on the LCD, press the [MIN] Button to turn off.
Adjust the “SET” value of the Bore Gauge to match the ID of the Ring Gauge Standard. Press and hold the [ABS/SET] Button until
“SET” blinks on the display.
Continue holding the [ABS/SET] Button and the display character to the left will blink. Use a short press of the [ABS/SET] Button to
change the value, and a long press to change the character being modified. Repeat this process to enter the dimension of the Ring
Gauge Standard on the LCD display. (Figure 4)
When the value is entered the flashing position will return to “SET”. A short
press of the [ABS/SET] Button to turn off the flashing.
Insert the Measurement Head into the Ring Gauge Standard and press
the [MIN] Button to put the Indicator into minimum-mode. Slowly pivot
the gauge (Figure 3) to display the minimum value.
Remove the gauge from the Ring Gauge and press the [CAL] button
until “OK” is momentarily displayed. Preparation for measurement is
now complete.
Put the gauge into the workpiece to be measured, and pivot the gauge
slowly. (Figure 3) The LCD will display the measured value. (Figure 5)
Press the [ON/ZERO] Button momentarily to reset display in
preparation to measure the next workpiece.
COMPARATIVE MEASUREMENTS
Difference between workpiece and reference
Turn on power. If or symbols are displayed on the LCD,
press the [MIN] Button to turn off. If “ABS” is displayed press the
[ABS/SET] Button to turn off.
Insert the Measurement Head into the Ring Gauge Standard and press
[MIN] Button to put the Indicator into minimum-mode. Slowly pivot the
gauge (Figure 3) to display the minimum value.
Remove the gauge from the Ring Gauge and press the [CAL] button
until “OK” is momentarily displayed.
Preparation for measurement is now complete.
Put the gauge into the workpiece to be measured, and pivot the gauge
slowly. (Figure 3) The LCD will display the difference between the
measured workpiece and the calibration standard. (Figure 6)
Press the [ON/ZERO] Button momentarily to reset display in preparation
to measure the next workpiece.
Ring Gauge
Standard
Work-
piece
Set to match
Workpiece I.D. value
Diff. between Work-
piece and Reference
Fig.
Fig.
Fig.
Work-
piece
TROUBLESHOOTING
ERROR CORRECTIVE ACTION
LCD does not display
Displayed value is unstable
Display is not clear
Cycle power by removing and
replacing battery.
Replace battery with new one.
If problem persists, or if you have any questions,
please contact distributor or place of purchase.
Please note, manufacturer is unable to respond to
inquires or provide service directly. Please contact
distributor or place of purchase.
Niigata Seiki Co., Ltd.
61522 , Tsukanome, Sanjo, Niigata, Japan 9550055
TEL: +81256315670 FAX: +81256397730
MAIL: intl .sales@niigataseiki.co.jp
URL http://www.niigataseiki.co.jp
/