Niigata seiki WCDI-160D User manual

Type
User manual

This manual is also suitable for

ABS/SET
MIN CAL
ZERO/ON
ABS/SET
MIN CAL
ZERO/ON
ABS
mm
Model:WCDI-50D/WCDI-100D/WCDI-160D combined
Clamp
Screw
Not including quantization error (±1 count)
Loosen the Clamp Screw and
insert the Digital Indicator into
the gauge body. Tighten the
Clamp Screw to secure.
After attaching, press the [ZERO/
ON] Button on the Digital Indicator
to turn on power. Confirm that the
displayed reading changes by
gently squeezing the measurement
head. If necessary, adjust the depth
that the Digital Indicator is inserted
into the gauge body.
Select the combination of Sub Rod (WCD-160 only) Extension
Rod and Washers for the dimension you want to measure.
Remove the Rod Adj. Nut put on the desired Sub Rod, Rod, and
Washers, and secure with the Extension Rod Mounting Nut.
ASSEMBLY
INSERT
Accessories
This is a precision instrument, handle with
care.
Do not disassemble or modify.
Keep instrument away from water and oil.
Use only with supplied Extension Rods
and Washer.
Keep instrument away from direct sunlight
and high temperatures such as in a car, or
near a stove or heat source.
After use, remove any dirt or cutting chips
and apply rust preventative oil to to
Extension Rod and Washer. When not in
use store in supplied storage case.
This product is for measuring inside
diameter; use only as directed. Improper
use may cause accident or injury.
Avoid using in high electric fields, such as
near fluorescent lights or switching power
supplies. Electrical interference may
cause incorrect readings.
NOTICE
INSERTING BATTERY
Pull out the case from the two
side edges to remove. Insert
battery with () side facing
down.
Use only CR2032 type lithium
button cell.
NOTICE
Battery
Case
Battery
Extension Rod
Sub Rod
only
Handle
Extension
Rod
Mounting
Nut
Shaft
Probe Tip
Length below Handle:
Measurement
Head
Washers
Guide
Ex. Rod Nut Ex. Rod
Ex. Rod
Ex. Rod
Washer Washer
Washer Sub Rod
Examples
To
Measure:
(1 each size)
Extension Rods
pieces
pieces
pieces
Sub Rod x only
Battery Lithium button cell, 1x (for test)
DIGITAL BORE GAUGE
Thank you for purchasing the Digital Bore Gauge.
Please read this manual thoroughly before use for proper operation.
Instruction Manual
Including supplied Digital Gauge
PART IDENTIFICATION SPECIFICATIONS
Model No.
Measuring Range
Resolution
Wide Range Acc'y
Adjacent Error
Repeat Accuracy
Washer
Single Stroke Range
Weight
Display
[]
Button
[] Button
[]Button
[]
Button
Clamp
Screw
Gauge
Digital Indicator
Cap Not Used
"0.01" indicates the resolution
of the display's digital bar
graph. The bar graph display
will change with each 0.01mm
change in the measured
value.
ACCESSORIES
Please select combination with fewest number of Washers.
To
Measure:
To
Measure:
ABS/SET
MIN CAL
ZERO/ON
ABS
mm
ABS/SET
MIN CAL
ZERO/ON
mm
39.998
ABS/SET
MIN CAL
ZERO/ON
ABS
mm
ABS/SET
MIN CAL
ZERO/ON
ABS
mm
MEASUREMENT
Fig. Fig. Fig.
For accurate measurements, follow the procedure described below.
In cross section perpendicular to the axis of the bore, as shown in Figure 1, position the gauge along diameter . This is the
maximum distance, and at this point the Indicator will read the maximum value. The Guide will automatically position the
Measurement Head to diameter when inserted.
In cross section parallel to to the axis of the bore through diameter , position the indicator to minimize the distance . (Figure 2)
In this position the Indicator will read the minimum value. This position must be manually determined by pivoting the Gauge as
shown in Figure 3 while watching the Indicator to find the minimum value.
OPERATION
Before use, please make sure the Measurement Head components are not loose and tighten if necessary.
Clean the Measurement Head and the ID of a Ring Gauge Standard using parts cleaner or cleaning solution.
Press the [ZERO/ON] Button to turn on power. A long press to the [ZERO/ON] Button will turn power off.
ABSOLUTE MODE (ABS)
Turn on power. If the “ ” or “
Measure absolute dimension of workpiece
” symbols are displayed on the LCD, press the [MIN] Button to turn off.
Adjust the “SET” value of the Bore Gauge to match the ID of the Ring Gauge Standard. Press and hold the [ABS/SET] Button until
“SET” blinks on the display.
Continue holding the [ABS/SET] Button and the display character to the left will blink. Use a short press of the [ABS/SET] Button to
change the value, and a long press to change the character being modified. Repeat this process to enter the dimension of the Ring
Gauge Standard on the LCD display. (Figure 4)
When the value is entered the flashing position will return to “SET”. A short
press of the [ABS/SET] Button to turn off the flashing.
COMPARATIVE MEASUREMENTS
Difference between workpiece and reference
Turn on power. If or symbols are displayed on the LCD,
press the [MIN] Button to turn off. If “ABS” is displayed press the
[ABS/SET] Button to turn off.
Insert the Measurement Head into the Ring Gauge Standard and press
[MIN] Button to put the Indicator into minimum-mode. Slowly pivot the
gauge (Figure 3) to display the minimum value.
Remove the gauge from the Ring Gauge and press the [CAL] button
until “OK” is momentarily displayed.
Preparation for measurement is now complete.
Put the gauge into the workpiece to be measured, and pivot the gauge
slowly. (Figure 3) The LCD will display the difference between the
measured workpiece and the calibration standard. (Figure 6)
Press the [ON/ZERO] Button momentarily to reset display in preparation
to measure the next workpiece.
Insert the Measurement Head into the Ring Gauge Standard and press
the [MIN] Button to put the Indicator into minimum-mode. Slowly pivot
the gauge (Figure 3) to display the minimum value.
Remove the gauge from the Ring Gauge and press the [CAL] button
until “OK” is momentarily displayed. Preparation for measurement is
now complete.
Put the gauge into the workpiece to be measured, and pivot the gauge
slowly. (Figure 3) The LCD will display the measured value. (Figure 5)
Press the [ON/ZERO] Button momentarily to reset display in
preparation to measure the next workpiece.
Ring Gauge
Standard
Work-
piece
Set to match
Workpiece I.D. value
Diff. between Work-
piece and Reference
Fig.
Fig.
Fig.
Work-
piece
TROUBLESHOOTING
ERROR CORRECTIVE ACTION
LCD does not display
Displayed value is unstable
Display is not clear
Cycle power by removing and
replacing battery.
Replace battery with new one.
If problem persists, or if you have any questions,
please contact distributor or place of purchase.
Please note, manufacturer is unable to respond to
inquires or provide service directly. Please contact
distributor or place of purchase.
Niigata Seiki Co., Ltd.
61522 , Tsukanome, Sanjo, Niigata, Japan 9550055
TEL: +81256315670 FAX: +81256397730
MAIL: intl.sale s@niigataseiki.co.jp
URL http://www.niigataseiki.co.jp