TOA ZM-9001 User manual

Category
Audio amplifiers
Type
User manual

This manual is also suitable for

TOA ZM-9001 is a remote control switch panel that can be used with TOA's 9000 Series amplifiers. It features six control buttons that can be assigned various functions, such as volume up/down or other functions. It is designed for mounting in a 1-gang electrical box and connects to the amplifier's REMT VOL terminal using a shielded cable. The ZM-9001 allows for remote control of input or output channels and is ideal for applications where quick and easy adjustments are required.

TOA ZM-9001 is a remote control switch panel that can be used with TOA's 9000 Series amplifiers. It features six control buttons that can be assigned various functions, such as volume up/down or other functions. It is designed for mounting in a 1-gang electrical box and connects to the amplifier's REMT VOL terminal using a shielded cable. The ZM-9001 allows for remote control of input or output channels and is ideal for applications where quick and easy adjustments are required.

ZONE MANAGERS
OPERATING INSTRUCTIONS
ZM-9001, ZM-9002
Thank you for purchasing TOA's Zone Manager.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
1. GENERAL DESCRIPTION
The ZM-9001 is a remote control switch panel used with the 9000 Series amplifiers.
It adds 6 control inputs and can be mounted in a 1-gang electrical box (American type).
The ZM-9002 is a remote control switch/volume panel used with the 9000 Series amplifiers.
It adds 4 control inputs and 1 volume control, and can be mounted in a 1-gang electrical box
(American type).
2. NOMENCLATURE AND FUNCTIONS
2.1. ZM-9001
[Front] [Rear]
1
3
5
2
4
6
E OUT
1
2
1. Control buttons [1 – 6]
Activate the function assigned to them when
pressed.
2. Control output terminal [E, OUT]
Connect this terminal to the 9000 Series
amplifier's REMT VOL terminal.
Use a shielded cable with 50 Ω or less line
resistance (per line) for this connection.
Avoid installation of this cable and power cables
in the same conduit. Separate piping.
2.2. ZM-9002
[Front] [Rear]
1
3
2
4
0
E OUT
3
4
5
3. Control buttons [1 – 4]
Activate the function assigned to them when
pressed.
4. Volume control
Adjusts the volume on the assigned input or
output channel.
5. Control output terminal [E, OUT]
Connect this terminal to the 9000 Series
amplifier's REMT VOL terminal.
Use a shielded cable with 50 Ω or less line
resistance (per line) for this connection.
Avoid installation of this cable and power cables
in the same conduit. Separate piping.
3. CONNECTIONS
Connecting the ZM-9001 Zone Manager to the 9000 Series amplifier adds 6 control inputs and
allows the equipped 6 control buttons to perform the functions assigned for input's or output's
channel volume up/down, or other functions.
Connecting the ZM-9002 Zone Manager to the 9000 Series amplifier adds 1 volume control and 4
control inputs. Volume of the input or output channels can be remotely adjusted with the volume
control, and the 4 control buttons can be assigned the same functions as those of the ZM-9001.
Function assignment to the control buttons or volume control is performed at the 9000 Series
amplifier. For the method, refer to the instruction manual supplied with the 9000 Series amplifier.
E
E
4
4
3
3
1
2
2
1
VOL2
REMT
VOL1
REMT
OUT
IN
I/O
CTRL
E
IN
E
IN
REMT VOL1
(Remote volume 1)
REMT VOL2
(Remote volume 2)
IN
E
IN
E
OUT
ZM-9001
E
1
2
3
4
5
6
1
2
3
4
Volume control
ZM-9002
OUT
E
REMT VOL terminal
9000 Series amplifier
Note
One ZM-9001 or one ZM-9002 can be
connected to each of the REMT VOL1 and
2 terminals.
5. SPECIFICATIONS4. DIMENSIONAL DIAGRAMS
5.1. ZM-9001
5.2. ZM-9002
Single conductor shielded cable
50 Ω or less (per line)
M3 screw terminal, distance between barriers: 7.62 mm
–10 to +40°C
Surface-treated steel plate, white, paint
72 (w) x 127 (h) x 45 (d) mm
170 g
Applicable Cable
Line Resistance
Terminal
Operating Temperature
Finish
Dimensions
Weight
Note: The design and specifications are subject to change without notice for improvement.
• Accessories
Machine screw (for box mounting)
No.6-32UNC x 30 .................................................................................. 2
M4 x 30 .................................................................................................. 2
Machine screw (for panel mounting) No.6-32UNC x 6 ............................... 2
Single conductor shielded cable
50 Ω or less (per line)
M3 screw terminal, distance between barriers: 7.62 mm
–10 to +40°C
Surface-treated steel plate, white, paint
72 (w) x 127 (h) x 56 (d) mm
170 g
Applicable Cable
Line Resistance
Terminal
Operating Temperature
Finish
Dimensions
Weight
Note: The design and specifications are subject to change without notice for improvement.
• Accessories
Machine screw (for box mounting)
No.6-32UNC x 30 .................................................................................. 2
M4 x 30 .................................................................................................. 2
Machine screw (for panel mounting) No.6-32UNC x 6 ............................... 2
[Front] [Front View without panel][Side]
[Figure when mounted] [Dimensions of mounting opening][Bottom]
1-gang electrical box (American type, not supplied)
1-gang electrical box (American type, not supplied)
[Figure when mounted] [Dimensions of mounting opening][Bottom]
[Front] [Front View without panel][Side]
Unit: mm
Unit: mm
72
33
45
37
66.4
97
70
66
83.5
97
104
127
6
32.6
38
42
83.5
90 – 98
46 – 50
46 – 50
83.5
90 – 98
38
42
66
83.5
97
104
32.6
70
56
637
72
33
66.4
97
127
4.2. ZM-9002
4.1. ZM-9001
133-05-401-5D
URL: http://www.toa.jp/
Traceability Information for Europe (EMC directive 2004/108/EC)
Manufacturer:
TOA Corporation
7-2-1, Minatojima Nakamachi, Chuo-ku, Kobe, Hyogo,
Japan
Authorized representative:
TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg,
Germany
  • Page 1 1
  • Page 2 2

TOA ZM-9001 User manual

Category
Audio amplifiers
Type
User manual
This manual is also suitable for

TOA ZM-9001 is a remote control switch panel that can be used with TOA's 9000 Series amplifiers. It features six control buttons that can be assigned various functions, such as volume up/down or other functions. It is designed for mounting in a 1-gang electrical box and connects to the amplifier's REMT VOL terminal using a shielded cable. The ZM-9001 allows for remote control of input or output channels and is ideal for applications where quick and easy adjustments are required.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI