6 DRX™ 3000 Impact Beds
Now you can calculate the impact energy (in lb.-.) and make the bed selection by the rating chart.
A sample DRX™ Impact Bed Spec Sheet
is included (Page 7) for future use.
1.4 Selecting the Right Impact Bar
e primary purpose of the impact bars is to absorb the energy of the falling material and prevent damage to
the belt. ey are the rst line of defense. Typical impact bars can be purchased with a 1/2" (13mm) UHMW
top cover or with a longer-wearing 1" (25mm) top cover. Care should be taken to choose the right top cover
thickness for your application to ensure maximum energy absorption.
Generally, impact bars are 3" (75mm) high and 4" (100mm) wide. ey are made up of an aluminum extrusion
base, an elastomer (rubber) center, and a low-friction (UHMW) top cover. e extrusion takes up about 1"
(25mm) of the bar’s height. at means that depending on the thickness of the top cover chosen (1/2" or 1"), the
energy-absorbing rubber core is either 1-1/2" (38mm) or 1" (25mm). Reducing the rubber core of each bar by
50% in heavier impact applications can reduce the impact bed’s eectiveness and performance.
Some general guidelines:
1. e impact bed’s primary use is for dust suppression with no sizeable
amount of impact (for loads not exceeding 1500 lb- of impact energy),
choose the 1" (25mm) top cover. It will oer twice the service life with no
measurable performance degradation.
2. For applications with 1500 lb- or more of impact force, the 1/2" (13mm)
top cover is strongly recommended. It will provide 50% more energy
impact protection for the belt.
1.5 Installation and Service Option
e DRX™ Impact Bed is designed to be easily installed and serviced by your on-site personnel. However, if you
would prefer complete turn-key factory service, please contact your local Flexco Field Engineer or your Flexco
Distributor.
Section 1 - Important Information
By using this simple lb-ft formula, for
whatever your application, you will
know the load capacities needed to
specify the best DRX™ Impact Bed to
get the job done right.
Calculate Impact Energy:
Lump weight _____________ lb
x Drop length _____________ ft
Total _____________ lb-ft
Drop Height (h)
Largest Material
Lump Weight (w)
Match lb-ft to bed rating:
Up to 200 lb-ft (25 kg-m) DRX 200
200 to 750 lb-ft (25 to 100 kg-m) DRX 750
750 to 1500 lb-ft (100 to 200 kg-m) DRX 1500
1500 to 3000 lb-ft (200 to 400 kg-m) DRX 3000
1"
(25mm)
½"
(13mm)
1"
(25mm)
1½"
(38mm)
1"
(25mm)
1"
(25mm)