Cumberland Actuated Small Ceiling Inlet Owner's manual

Type
Owner's manual

Cumberland Actuated Small Ceiling Inlet

The Cumberland Actuated Small Ceiling Inlet (ACI-2-1228-KIT) is a versatile device designed to provide controlled ventilation in various agricultural and industrial settings. With its robust construction and adjustable features, this inlet allows for precise airflow management and optimization of indoor environments.

The ACI-2-1228-KIT is suitable for installation in ceilings with rough openings of 11-1/2" x 27-1/2". Its durable frame and insulation stop ensure a secure fit and prevent air leakage. The inlet can be equipped with one or two 1/8" rods, providing flexibility in door control. Multiple nylon cords enable connection to a central actuation system, allowing for remote operation and synchronization with other inlets.

Cumberland Actuated Small Ceiling Inlet

The Cumberland Actuated Small Ceiling Inlet (ACI-2-1228-KIT) is a versatile device designed to provide controlled ventilation in various agricultural and industrial settings. With its robust construction and adjustable features, this inlet allows for precise airflow management and optimization of indoor environments.

The ACI-2-1228-KIT is suitable for installation in ceilings with rough openings of 11-1/2" x 27-1/2". Its durable frame and insulation stop ensure a secure fit and prevent air leakage. The inlet can be equipped with one or two 1/8" rods, providing flexibility in door control. Multiple nylon cords enable connection to a central actuation system, allowing for remote operation and synchronization with other inlets.

Date: 03-16-23 V3.0 PNEG-2397
Instructions
1004 East Illinois Street • Assumption, IL 62510 • 1-217-226-4421
PNEG-2397
Page 1 of 9
Printed in the USA
Copyright © 2023 by The GSI Group, LLC
www.automatedproduction.com /
www.cumberlandpoultry.com
CN-409048
Actuated Small Ceiling
Inlet Installation
Installing the Actuated Small Ceiling Inlet (ACI-2-1228-KIT)
1. Frame rough opening in the ceiling for each inlet.
2. Staple the insulation stop (29) to the frame’s opening (35), making sure it is flush with the bottom side
of the frame opening (35). (See Figure 1.)
Figure 1 Securing the Insulation Stop
3. Center the inlet (30) within the framed opening (35). (See Figure 2.)
4. Attach the inlet (30) to the frame opening (35) using eight #10 x 1-1/2" SMSA screws (6).
NOTE: Use a 1/4" hex head drive to install the screws (6). The locations (38) to install the screws (6)
are marked on the inlet (30) frame with a boss.
Figure 2 Installing the Inlet to the Frame Opening
Model Rough Opening Description
ACI-2-1228-KIT 11-1/2" x 27-1/2" With the Insulation Stop
ACI-2-1228 11-3/8" x 27-3/8" Without the insulation Stop
Ref # Description
29 Insulation Stop (30-1384)
35 Frame Opening (11-1/2" x 27-1/2")
Ref # Description Ref # Description
6#10 x 1-1/2" SMSA Screw (S-10819) 35 Frame Opening
30 Inlet Assembly (ACI-2-1228-KIT) 38 Screw Locations
Page 2 of 9 PNEG-2397
Actuated Small Ceiling Inlet Installation
5. Run the 1/8" rods (36) through the inlet (30).
a. If using one rod (36), run it through the center slot in the inlet (30).
b. If using two rods (36), run them through the outside holes in the inlet (30).
6. Measure approximately 25" (minimum 18") from the outside of the inlet and fasten the nylon cords
(31) to the 1/8" rods (36) using 1/8" cable clamps (32).
7. Thread the nylon cord (31) through the stationary pulleys (10 and 11) then down through the
door (18).
NOTE: Make sure the nylon cord (31) goes around the stationary pulleys (10 and 11) as shown in
Figure 3.
8. Close the door (18) and slide the plastic ball (33) onto the nylon cord (31), then fasten closed with
azuma nut (34).
9. Cut-off the excess nylon cord (31), leaving 3"-4" below the azuma nut (34) for adjustment.
NOTE: The nylon cord (31) will stretch. Re-adjust the azuma nut (34) as needed to keep the
door (18) closed.
Figure 3 Attaching the Nylon Cords to the Door and Rod
Ref # Description Ref # Description
10 Static Pulley (30-1235) 32 1/8" Cable Clamp (S-8946)
11 Middle Pulley (30-1277) 33 Plastic Red Ball (FLX-2442)
18 Door (30-1371) 34 Plastic Azuma Nut (35-0018)
30 Inlet Assembly (ACI-2-1228-KIT) 36 1/8" Rod
31 Nylon Cord (35-0118)
36
33
18 34
33
18
34
30 36
11
10
31
32
31
31 31
31 31
36
32
Top view
Top view
36
32
11
10
31
32
36
30
31
Approximately 25"
(minimum 18") from
the side of the inlet
Approximately 25"
(minimum 18") from
the side of the inlet
One rod Two rods
Benefits of two rods controlled ACI inlets:
1. Close half of the doors without having to close them by hand.
2. Stagger inlets rigging.
• Open-close both doors on ever other inlets in a row.
3. Alternate door rigging.
• Independently open-close doors on an inlet.
4. Create the air flow zones in a room or building.
PNEG-2397 Page 3 of 9
Actuated Small Ceiling Inlet Installation
10. Pull the rubber latches (14) into the door locks (37) if you do not want the doors (18) to open when
actuated.
Figure 4 Locking the Doors
Inlet Configurations
Figure 5 Possible Inlet Door Setups
Ref # Description
14 Rubber Inlet Latch (30-1202)
18 Door (30-1371)
37 Door Lock
Alternating inlet setupStaggered inlet setup
Cable A connects to Left Door.
Cable B connects to Right Door.
Cable A connects to Right Door.
Cable B connects to Left Door.
Cable A connects to Right Door.
Cable B connects to Left Door.
L - Left Door
R - Right Door
Cable A connects to Left Door.
Cable B connects to Right Door.
Both doors are connected
to Cable A.
Both doors are connected
to Cable B.
Both doors are connected
to Cable A.
Both doors are connected
to Cable B.
Inlet #1
RL
RL
RL
RL
Inlet #2
Inlet #3
Inlet #4
Inlet #1
RL
RL
RL
RL
Inlet #2
Inlet #3
Inlet #4
Cable A Cable B Cable A Cable B
Page 4 of 9 PNEG-2397
Actuated Small Ceiling Inlet Installation
Pulley Layouts
Figure 6 Possible System Layout
End Installation - One Row of Inlets (2 to 1)
Figure 7
PNEG-2397 Page 5 of 9
Actuated Small Ceiling Inlet Installation
Middle Installation - One Row of Inlets (2 to 1)
Figure 8
Page 6 of 9 PNEG-2397
Actuated Small Ceiling Inlet Installation
End Installation - Two Rows of Inlets (2 to 1)
Figure 9
PNEG-2397 Page 7 of 9
Actuated Small Ceiling Inlet Installation
Middle Installation - Two Row of Inlets (2 to 1)
Figure 10
Page 8 of 9 PNEG-2397
Actuated Small Ceiling Inlet Installation
Ceiling Inlet Assembly Parts (ACI-2-1228-KIT)
PNEG-2397 Page 9 of 9
Actuated Small Ceiling Inlet Installation
Ceiling Inlet Assembly (ACI-2-1228-KIT) Parts List
Ref # Part # Description Qty
130-1245-12 28" x 12" Ceiling Inlet Frame 1
2 30-1269 Ceiling Inlet R.H. End Cap Assembly 2
330-1270 Ceiling Inlet L.H. End Cap Assembly 2
430-1242-12 12" Ceiling Inlet Side Foam 2
530-1243 Ceiling Inlet End Foam 2
6S-10819 Screw, SMSA #10 x 1-1/2" EHH SS 8
7S-10821 Screw, SMSA #8 x 3/4" FHP SS 2
8S-10822 Screw, SMSA #8 x 5/8" RHP SS 4
930-1369 Kit, Service Parts ACI-2-X Inlets 1
10 30-1235 Ceiling Inlet Static Pulley 2
11 30-1277 Ceiling Inlet Middle Pulley 1
12 30-1238 Ceiling Inlet Lock Pin 2
13 30-1204 Pin Cap Bracket 2
14 30-1202 Ceiling Inlet Latch 4
15 S-10820 Screw, TFS #10 x 1/2" RHP SS 2
16 S-10823 Screw, SMSA #8 x 1" FHP SS 16
17 30-1337 Grommet, Slot 1.2" x 0.20" 2
18 30-1371 Door, Assembly ACI-2-1228 1
19 30-1246-12 12" Ceiling Inlet Door Extrusion 1
20 30-1244-12 12" Ceiling Inlet Door Foam 1
21 30-1259-12 12" Ceiling Inlet Door Foam 4
22 S-10823 Screw, SMSA #8 x 1" FHP SS 16
23 30-1273 Ceiling Inlet R.H. End Cap P3 1
24 30-1272 Ceiling Inlet R.H. End Cap P2 1
25 30-1271 Ceiling Inlet R.H. End Cap P1 1
26 30-1276 Ceiling Inlet L.H. End Cap P3 1
27 30-1275 Ceiling Inlet L.H. End Cap P2 1
28 30-1274 Ceiling Inlet L.H. End Cap P1 1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Cumberland Actuated Small Ceiling Inlet Owner's manual

Type
Owner's manual

Cumberland Actuated Small Ceiling Inlet

The Cumberland Actuated Small Ceiling Inlet (ACI-2-1228-KIT) is a versatile device designed to provide controlled ventilation in various agricultural and industrial settings. With its robust construction and adjustable features, this inlet allows for precise airflow management and optimization of indoor environments.

The ACI-2-1228-KIT is suitable for installation in ceilings with rough openings of 11-1/2" x 27-1/2". Its durable frame and insulation stop ensure a secure fit and prevent air leakage. The inlet can be equipped with one or two 1/8" rods, providing flexibility in door control. Multiple nylon cords enable connection to a central actuation system, allowing for remote operation and synchronization with other inlets.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI