Legal Considerations
Video and audio surveillance can be prohibited by laws that
vary from country to country. Check the laws in your local
region before using this product for surveillance purposes.
Electromagnetic Compatibility (EMC)
This equipment has been designed and tested to fulfill
applicable standards for:
• Radio frequency emission when installed according to the
instructions and used in its intended environment.
• Immunity to electrical and electromagnetic phenomena
when installed according to the instructions and used in
its intended environment.
USA - This equipment has been tested using a shielded
network cable (STP) and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more
of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
Canada - This Class B digital apparatus complies with
Canadian ICES-003.
Europe - This digital equipment fulfills the
requirements for RF emission according to the Class B limit
of EN 55022.
Australia - This digital equipment fulfills the
requirements for RF emission according to the Class B limit
of AS/NZS CISPR 22.
Safety
This product complies with IEC/EN/UL 60950-1 and
IEC/EN/UL 60950-22, Safety of Information Technology
Equipment.
Japan - B
Korea -
ࢇ̛̛Еɼࢽࡈ%̗ࢷ࢕ળࢶଢ̛̛Ի۰
࣯Իɼࢽ߾۰یࡈଜЕʨࡶּࢶࡳԻଜֲֻҘ
एࠇ߾۰یࡈଟܹ࢑ݡТЬ
Equipment Modifications
This equipment must be installed and used in strict
accordance with the instructions given in the user
documentation. This equipment contains no
user-serviceable components. Unauthorized equipment
changes or modifications will invalidate all applicable
regulatory certifications and approvals.
Liability
Every care has been taken in the preparation of this
document. Please inform your local Axis office of any
inaccuracies or omissions. Axis Communications AB cannot
be held responsible for any technical or typographical errors
and reserves the right to make changes to the product and
documentation without prior notice. Axis Communications
AB makes no warranty of any kind with regard to the
material contained within this document, including, but not
limited to, the implied warranties of merchantability and
fitness for a particular purpose. Axis Communications AB
shall not be liable nor responsible for incidental or
consequential damages in connection with the furnishing,
performance or use of this material. This product is only to
be used for its intended purpose.
RoHS
This product complies with both the European RoHS
directive, 2002/95/EC, and the Chinese RoHS
regulations, ACPEIP.
WEEE Directive
The European Union has enacted a Directive
2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE Directive). This directive is
applicable in the European Union member states.
The WEEE marking on this product (see right) or
its documentation indicates that the product
must not be disposed of together with household waste. To
prevent possible harm to human health and/or the
environment, the product must be disposed of in an
approved and environmentally safe recycling process. For
further information on how to dispose of this product
correctly, contact the product supplier, or the local
authority responsible for waste disposal in your area.
Business users should contact the product supplier for
information on how to dispose of this product correctly. This
product should not be mixed with other commercial waste.
Support
Should you require any technical assistance, please contact
your Axis reseller. If your questions cannot be answered
immediately, your reseller will forward your queries through
the appropriate channels to ensure a rapid response. If you
are connected to the Internet, you can:
• download user documentation and software updates
• find answers to resolved problems in the FAQ database.
Search by product, category, or phrase
• report problems to Axis support staff by logging in to your
private support area
• chat with Axis support staff (selected countries only)
• visit Axis Support at www.axis.com/techsup/
ENGLISH
Safeguards
Store the Axis product in a dry and ventilated environment.
Avoid exposing the Axis product to vibration, shocks or heavy pressure. Do not install the product on unstable
brackets, unstable or vibrating surfaces or walls, since this could cause damage to the product.
Only use applicable tools when installing the Axis product; excessive force could cause damage to the prod-
uct.
Do not use chemicals, caustic agents, or aerosol cleaners. Use a damp cloth for cleaning.
Use only accessories that comply with technical specification of the product. These can be provided by Axis or
a third party.
Installation and removal of AXIS T8123-E/T8124-E must be carried out by qualified personnel only.
The equipment is intended only for installation in a Restricted Access Location.
This product is not intended to become a permanent part of the building structure.
Read this Installation Guide before connecting AXIS T8123-E/T8124-E to its power source.
Follow basic electricity safety measures whenever connecting AXIS T8123-E/T8124-E to its power source.
Power supply cord must not be attached to the building surface nor run through walls, ceilings, floors and
similar openings in the building structure.
Measures must be taken to prevent physical damage to the power supply cord, including proper routing.
A voltage mismatch can cause equipment damage and may pose a fire hazard. If the voltage indicated on the
label is different from the power outlet voltage, do not connect AXIS T8123-E/T8124-E to this
power outlet.
US version only. All wiring and connections shall be in accordance with NFPA 70 (NEC).
US version only. This product is fitted with a NEMA 5-15P plug for connection to the branch circuit. If other
attachment methods are required, please reference local codes and requirements for proper connection to the
branch circuit.
AXIS T8123-E/T8124-E AC power plug shall be connected to a sealed box in order to meet
EN 60529 level IP66 and NEMA 250 level 4x.
AXIS T8123-E/T8124-E AC power lines shall be connected to the socket-outlet, which shall be installed near
the equipment and easily accessible.
International version only. AXIS T8123-E/T8124-E AC power lines shall be connected via an external 2-pole
circuit breaker to the normal building installation wiring.
AXIS T8123-E/T8124-E "DATA IN" and "DATA PWR OUT" ports are shielded RJ45 data sockets. They cannot be
used as Plain Old Telephone Service (POTS) sockets. Only RJ45 data connectors can be connected to these
sockets.
Ensure cable length from Ethernet network source does not exceed 100 m (333 ft). AXIS T8123-E/T8124-E is
not a repeater and does not amplify the Ethernet data signal.
Use a splitter if desired, ensure that the splitter is connected close to the terminal and not on the Midspan.
Designed to meet GR-1089-CORE lightning protection demands.
This Axis product shall be used in compliance with local laws and regulations.
Do not attempt to repair the product by yourself, contact Axis or your Axis reseller for service matters
Installation and removal of AXIS T8123-E/T8124-E must be carried out by qualified personnel only.
AXIS T8123-E/T8124-E Installation Guide Page 5
ENGLISH
AXIS T8123-E/T8124-E
Installation Guide
Package Contents
Note: Ethernet cable, RJ45 male connectors and mounting screws are not part of the delivery
Functions and Features
AXIS T8123-E/T8124-E 1-Port 802.3at Gigabit PoE Outdoor Midspan injects power over data
carrying Ethernet cabling. It maintains IEEE802.3at and IEEE802.3af standards. These power levels
allow usage by a new range of Ethernet-based applications such as video phones, 802.11n Access
Points, WiMAX Transmitters, PTZ cameras and more. AXIS T8123-E/T8124-E DATA PWR OUT port is
designed to carry Gigabit Ethernet data and power over a standard CAT5e cable, delivered through
4-pairs (Alt A: pins 1,2(-) / 3,6(+) and Alt B: pins 4,5(+) / 7,8(-)).
AXIS T8123-E/T8124-E
Midspan with pre-installed power cable
(power cable country specific)
International
USA
Mounting kit 2X RJ45 male plug waterproof
connectors covers
Grounding wire
Printed material Installation Guide (this document)
AC power cable color code Line Neutral Protective earth
US version - NFPA 70 (NEC) Black White Green
International version - IEC 60445 Brown Blue Green/Yellow
Page 6 AXIS T8123-E/T8124-E Installation Guide
Install the Hardware
AXIS T8123-E/T8124-E may be wall or bench mounted using the rear side holes.
Note the following before mounting AXIS T8123-E/T8124-E to a fixed location:
Do not cover AXIS T8123-E/T8124-E or block the airflow to the product with any foreign
object. Keep AXIS T8123-E/T8124-E away from excessive heat and humidity, and free from
vibration and dust.
Ensure that the cable length from the Ethernet network source to your Axis video product
does not exceed 100 meters (333 ft). AXIS T8123-E/T8124-E is not a repeater and does not
amplify the Ethernet data signal.
There is no "on-off" switch; simply plug AXIS T8123-E/T8124-E into an AC power outlet
installed near the equipment and easily accessible. For the international version of
AXIS T8123-E/T8124-E AC power line shall also be connected via an external 2-pole circuit
breaker to the normal building installation wiring.
To mount:
1. Fasten AXIS T8123-E/T8124-E with three screws. See Fig 1 (screw holes are marked 1, 2 and 3).
2. Connect one end of the grounding wire to EARTH GROUND (see fig 1b) and the other end to an
appropriate ground location. Make sure that this step (2) is performed before connecting
AXIS T8123-E/T8124-E to its power source! Use the supplied ground wire or a wire of equal or
larger area.
Note: When mounting the AXIS T8123-E/T8124-E make sure to use appropriate screws and plugs
for the surface (wood, concrete etc.). Do not unscrew the four pre-mounted screws
located in every corner of the product, since this violate the warranty of the product.
46.36
196
Fig 1
Fig 1b
1
EARTH GROUND
2 3
AXIS T8123-E/T8124-E Installation Guide Page 7
ENGLISH
3. Thread male plug waterproof connector cover (A,B and C) on to the Ethernet cable. See Fig 3.
4. Attach the Ethernet cable to DATA IN. See Fig 2.
5. Thread plug (A) over the RJ45 male plug, connected to DATA IN. See Fig 3.
6. Thread housing (B) over the plug and screw (hand tight only). See Fig 3.
7. Thread cover (C) over the connector and screw (hand tight only). See Fig 3.
8. Repeat steps 2 to 6 for DATA PWR OUT.
9. Connect AXIS T8123-E/T8124-E to an AC power line (100-240 V AC) complying with the
information in the Safeguards.
International version only. See Fig 4.
Note: Do not use cross over cable between AXIS T8123-E/T8124-E output port and load device.
DATA IN
DATA PWR OUT
LINE AC
L
N
N
PE
L
PE
Fig 2
Fig 3
RJ45
male plug
A
B
C
RJ45 male plug
waterproof
connector
cover
Fig 4
INCOMING
MAINS VOLTAGE
EXTERNAL PROTECTIVE
GROUND WIRE
Page 8 AXIS T8123-E/T8124-E Installation Guide
Specifications
Environmental
Electrical
Interface
Mode Temperature Relative humidity IP Class
Operating
AXIS T8123-E
-40°C to 50°C for 30 Watts (-40°F to 131°F)
-40°C to 65°C for 15.4 Watts (-40°F to149°F)
10 to 100%
(condensing) IP66
Operating
AXIS T8124-E
-40°C to 50°C for 60 Watts (-40°F to 131°F)
-40°C to 65°C for 30 Watts (-40°F to 149°F)
Storage -40°C to 85°C (-40°F to 185°F) Max 95%
(non-condensing)
N/A
Input Voltage 100-240 V AC (50/60 Hz)
Input Current AXIS T8123-E 1 Ampere (max)
Input Current AXIS T8124-E 2 Ampere (max)
Available Output Power (max) AXIS T8123-E 30 Watt
Available Output Power (max) AXIS T8124-E 60 Watt
Nominal Output Voltage 55 V DC
Input (DATA IN):
Ethernet 10/100/1000Base-T
RJ45 female socket
Output (DATA PWR OUT):
Ethernet 10/100/1000Base-T, plus 55 V DC
RJ45 female socket, with DC voltage on wire pairs
1-2 & 3-6, 4-5 & 7-8.
Power Cable (LINE AC) Pre-installed 3m power cable
AC power cable color code Line Neutral Protective earth
US version - NFPA 70 (NEC) Black White Green
International version - IEC 60445 Brown Blue Green/Yellow
AXIS T8123-E/T8124-E Installation Guide Page 9
ENGLISH
Troubleshooting
Warranty
For information about Axis product warranty and thereto related information, see
www.axis.com/warranty
Symptom Corrective Steps
AXIS T8123-E/
T8124-E does
not power up
1. Verify a reliable power cord is used.
2. Verify voltage at the power inlet is between 100-240 V AC.
3. Remove and reapply power and check the indicators on the powered device
during power up sequence.
A port indicator
on the powered
device is not lit
and the device
does not operate
1. Verify the Midspan detects a device.
2. Verify that the device is designed for PoE operation
3. Verify you are using a standard Category 5/5e/6, straight-wired cable, with
four pairs.
4. If an external power splitter is in use, replace it with a known good splitter
5. Ensure input Ethernet cable is connected to the DATA IN port.
6. Verify that the device is connected to the DATA PWR OUT port.
7. Try to reconnect the same powered device into a different Midspan. If it
works, there is probably a faulty port or RJ45 connection.
8. Verify there is no short over any of the twisted pair cables or over the
RJ45 connectors.
The end device
operates, but
there is no data
link
1. Verify the port indicator on the powered device is continuously lit.
2. If an external power splitter is in use, replace it with a known-good splitter.
3. Verify that for this link, you are using standard UTP/FTP Category 5 straight
(non-crossover) cabling, with all four pairs.
4. Verify Ethernet cable length is less than 100 meters from Ethernet source to
load/remote terminal.
5. Try to reconnect the same powered device into a different Midspan. If it
works, there is probably a faulty port or RJ45 connection.
Page 16 AXIS T8123-E/T8124-E Guide d'installation
DATA IN
DATA PWR OUT
LINE AC
L
N
N
PE
L
PE
Fig 2
Fig 3
RJ45
Prise mâle
A
B
C
Prise mâle RJ45
cache
connecteur
étanche
Fig 4
TENSION
D'ENTRÉE
CONDUCTEUR DE TERRE
DE PROTECTION EXTERNE
D'ALIMENTATION
Pagina 32 AXIS T8123-E/T8124-E Guida all'installazione
DATA IN
DATA PWR OUT
LINE AC
L
N
N
PE
L
PE
Fig 2
Fig 3
RJ45
maschio RJ-45
A
B
C
Connettore maschio RJ45
Copertura impermeabile
Fig 4
TENSIONE DI RETE
IN INGRESSO
CAVO DI TERRA
DI PROTEZIONE ESTERNO
Installation Guide
Ver.1.2
AXIS T8123-E/T8124-E
Printed: November 2012
© Axis Communications AB, 2012
Part No. 49679
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Axis T8124-E User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI