  • Hello! I am an AI chatbot trained to assist you with the Powers HydroGuard Checkstops Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Refer to charts on page 2 for repair/replacement kits for all four
styles of stop valves.
TYPE 1 1/2” NPT Triple Duty Strainer Checkstop
for Concealed Piping
TYPE 2 1/2” NPT Triple Duty Strainer Checkstop
for Exposed Piping
For shower mixers, concealed and exposed fotoguards
TYPE 3 1/2” NPT Triple Duty Strainer Checkstop Union
Type for Exposed Piping
Obsolete
TYPE 4 OBSOLETE
Used for H Hydroguards and H Fotoguards Prior to 1966
1. Connect fittings to the mixer with the bonnet [7] and stem [8] in
an accessible position (refer to drawing below for orientation).
2. Make sure stop valves are open by turning stem [8] fully
counter-clockwise.
TECHNICAL INSTRUCTIONS
1/2” NPT Check Valves
Combination Strainer-Checkstops
DESCRIPTION
INSTALLATION
2
1
Strainer
O-ring
Poppet with
Spring
Washer
3
4
5
6
7
8
O-ring/
Gasket
Body
Bonnet
Stem
1
2
3
4
5
6
7
8
9
10
Bonnet
O-ring
O-ring
Washer
Strainer
Poppet with
Spring
Body
Stem
Union Nut
Union End
1
2
5
Strainer
Assembly
O-Ring
Poppet Assembly
5-7⁄ 8" [14.9 cm]
1/2" NPT Outlet
1/2" NPT
Hot Water Inlet
1/2" NPT
Cold Water Inlet
2"
[51]
410 or 420 Valve
1/2" NPT
Triple Duties
1-5⁄ 8" [41]
Form TI230-1 V3
TI230-1 V3 Page 2
MAINTENANCE
PARTS/REPAIR KITS
KIT COMPONENTS (parts for one pair of stop valves)
Preventative Maintenance
1. To ensure proper operation, the checkstops should be
inspected for worn parts and cleaned every 6 months.
Cleaning Checkstops [1]
1. Close the checkstop by turning the stem [8] fully clockwise
to a solid stop.
2. Remove the bonnet [7] by turning counterclockwise.
3. Pull out screens [1] and clean.
4. Replace the screen [1] and bonnet [7]
5. Open the stop valves by turning the stem [8] fully counter-
clockwise.
Replace/repair check valve/spring
1. Shut off water supply upstream.
2. Remove the bonnet [7] and the stem [8].
3. Inspect or repair poppet or spring [5]. Replace assembly if
necessary.
4. Replace bonnet and stem.
5. Open stop valves by turning stem fully counterclockwise.
6. Turn on supply water.
Checkstop Types 1, 2, and 3:
230 131 O-ring [2], Bonnet Gasket/O-ring [ 3]**, Washer [4]
230 132 Strainer Assembly/Screen[1], O-ring [2], Bonnet
Gasket/O-ring[3]** , Washer [4], Poppet Assembly [5]
Checkstop Type 4 (Obsolete valve):
230 130 Strainer Assembly [1], O-ring [2]
230 129 Poppet Assembly [5]
230 128 O-ring [2]
Part Description Type 1 Type 2 Type 2 Type 3 Type 3 Type 3 Type 4
Rough Bronze Bright Chrome Polished Chrome Rough Bronze Bright Chrome Polished Chrome Obsolete
(Obsolete) (Obsolete) (Obsolete)
1 PAIR (1 RH, 1 LH complete C/S) 230 046 230 047 230 048
LEFT (1 LH complete C/S) 230 040 230 041 230 042
RIGHT (1 RH complete C/S) 230 043 230 044 230 045
1 Strainer Assembly 230 130
Screen 230 084 230 084 230 084 230 084 230 084 230 084 230 084
2 O-ring 230 131 230 131 230 131 230 131 230 131 230 131 230 128
230 132 230 132 230 132 230 132 230 132 230 132
3 Bonnet Gasket/O-ring 230 131 230 131 230 131 230 131 230 131 230 131
** 230 132 230 132 230 132 230 132 230 132 230 132
4 Washer 230 131 230 131 230 131 230 131 230 131 230 131
230 132 230 132 230 132 230 132 230 132 230 132
5 Poppet & Spring Assy. 230 132 230 132 230 132 230 132 230 132 230 132 230 129
6 Body Replace whole checkstop assembly (see first three rows above)
7 Bonnet 230 076A 230 077A 230 078A 230 076A 230 077A 230 078A
8 Stem 230 079 230 080 230 081 230 079 230 080 230 081
9 Union Nut 601 004
10 Union Tail 601 005
** All checkstops manufactured before date code J44 (Nov. ’94) use a flat gasket for part 3. All models manufactured after date code J44 (Nov ’94) have a modified body,
and require an O-ring for part 3. Refer to the stamp on the valve bonnet for the date code. Kits for Types 1, 2 and 3 contain both parts for repair.
TI230-1 V3 0326 EDP# 6508915 Printed in U.S.A.
USA office: Phone: 800.669.5430 • Fax: 847.824.0627
Canadian office: Phone: 888.208.8927 • Fax: 888.882.1979
© 2003 Powers, a Watts Industries Co.
www.powerscontrols.com
CALIFORNIA PROPOSITION 65 WARNING
WARNING: This product contains chemicals
known to the State of California to cause cancer
and birth defects or other reproductive harm.
(Installer: California law requires that this warning
be given to the consumer.)
For more information: www.wattind.com/prop65
/