Identification:
Technical
Bulletin no:
Date:
Issuer:
Factory:
D03-D04-D05
CG2007-19 (page 1 of 2), 1
st
ed.
31 July 2007
R. Sartor (DWS Customer Support)
DW Vallenoncello - Italy
Contactor for Boiler Heater in UW, HT and PW
Subject
Model
Front Loading (LU7 / WTU40), Hood Type medium capacity (LS9 / WT55),
Hood Type high capacity with 9 kW boiler power (WT65 / Ecotemp12) and
Manual Pot & Pan Washer (PW1M-2M / WT830M-850) ranges.
Problem
Stuck main board relays for boiler heater.
Reason
The current load has exceeded the maximum allowed current load (16 A).
This usually happens when the voltage supply for the machine is higher than
specified (e.g. three-phase 400 V +10% = 440 V or single-phase 230 V +10%
= 253V).
Actions in
Factory
Since serial number 73100001 we have introduced a contactor between main
board and boiler heater. Therefore the electrical wiring harnesses change as
follow:
Model
OLD
el. wiring
NEW
el. wiring
Additional
contactor
LU7 / WTU40 0L0732 0L0732 (638678201)
LU7WS / WTU40WS 0L1444 0L1444 (638685201)
LS9 / WT55 638679001 0L1414
WT65 with 9 kW boiler power 0L0466
0L0467
(already in use for LS14 / WT65 with
10.5 kW boiler power)
0L0285 (50Hz)
0L0286 (60Hz)
0L0430 (Japan)
PW1M-2M 0L0619 0L0619 (638668005)
WT830M-850M 0L0469 0L0469 (638672702)
none
(see below)
Hood Type high capacity with 10.5 kW boiler power (LS14EA / WT65E) and Automatic Pot & Pan
Washer (WT830EA-850EA) have had the contactor for boiler heater since their production start.
ELECTROLUX PROFESSIONAL SPA
MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380650 www.electrolux.com 00072220932
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380636
++39 0434 385646
Share more of our thinking at www.electrolux.com