10
Section 4
* FOR QUALIFIED
ENGINEERS ONLY
INSTALLATION AND CONNECTION
INSTRUCTIONS FOR PUTTING THIS
EQUIPMENT TO USE.
GENERAL
• Unpack the unit from its transportation
packing and visually check for any signs
of damage.
• Place the unit in a convenient location in
the cellar or room where it is to be sited.
• Always site the cooler on a dry, level surface
to avoid e.g. spillage and any unnecessary
noise or vibration. If mounting the unit o
the oor, ensure that:-
o The surface is clean, at and dry,
o The surface is of su cient size to support
the unit without it overhanging,
o The surface can support the weight of the
full, operational unit,
o The unit, when mounted, is stable and
cannot slip or be pushed o the surface. If
necessary, secure the unit and/or mounting
surface to a solid xing point such as an
outside wall.
• Do not site unit beside heat sources, e.g.
dishwashers.
• Make sure that a mains electricity supply is
within 2 meters and in an area allowing free
circulation of air.
• The unit should be tted with a correctly
fused and wired 13 amp plug tted with a
10 amp fuse or alternatively a standard Euro
Plug to IEC83:1975.
CONNECTION & OPERATING
INSTRUCTIONS FOR PUTTING THE
MACHINERY INTO USE
1. Ensure the cooler is installed in a well-ventilated
dry location on a level surface with no
obstructions to the condenser or front and side
ventilation slots. The unit must not be installed
in an area where it will be exposed to
temperatures, which are likely to cause freezing,
(i.e. below 0°C) or are in excess of 32°C.
2. Remove the bath ller cap and ll the water
bath to the over ow with cold clean water.
Catch any excess water owing out of the
over ow in an appropriate container to
avoid spillage.
3. Connect the appropriate tubes within the
python to the cooler and dispense font using
appropriate ttings, identifying the connections
from the labels on the cooler and font. Insulate
all connections made using appropriately sized
tube insulation to prevent condensation.
4. Ensure that the python run is not excessive,
and is routed away from external heat sources.
Maximum lift is 3.5 meters and maximum run
is 6 meters when using 3/8” o/d tubing for
recirculation. Longer runs are possible if 1/2”
o/d tubing is used.
5. Connect the tubing from the product supply to
the cooler identifying the connections from
the labels on the cooler and pressurise the lines
with product ensuring there are no leaks.
6. Do not block the over ow and ensure that it
is facing downwards.
7. Plug the cooler’s mains lead into the mains
socket and switch the unit on.
8. Ensure that the water is recirculating to the
font and back and ensure there are no leaks
from any of the connections.
9. The water level must be checked and topped
up once the lines have been primed.
Note: If the fridge unit is operated to make
the ice-bank whilst the installation is being
completed, t a short loop to the recirculation
pump line and leave the pump running whilst
the ice is building. This will stop any
over-icing or ice quality problems that might
otherwise occur.
11
Section 5
(FOR QUALIFIED ENGINEERS ONLY)
ELECTRONIC CONTROLLER SETTINGS AND
ADJUSTMENT INSTRUCTIONS.
DFX SERIES 1E CONTROLLER AND PROBE:
The controller is electronic, and is supplied with a
temperature probe. The cut-out and cut-in
temperatures are factory set at Manitowoc
Beverage Systems, and should not require any
adjustment.
They are as follows:
• Cut-out -2.0°C
• Cut-in +0.5°C
However, the controller has a built-in feature
that allows each individual account operating
pro le to be set-up to optimise power usage.
This feature conserves energy by powering down
the cooler overnight, during the account closed
period. There is a 7-day timer in the software,
with factory default settings which shut the
cooler down at 11:00pm and re-start the cooler
at 11:00am. For accounts where this pro le is
inappropriate, the timer must be set-up to suit
the individual account, in order to maximise
energy savings. Please refer to the Dfx Series 1e
Instruction Manual sent with the unit for
guidance on setting up this feature.
Adjustment Guide:
Note: The Cut-out (1.) and Di erential
temperature (2.) are factory set at Manitowoc
Beverage Systems. Any adjustment to these
settings may a ect the performance, energy
saving characteristic and ice weight of the unit. It
is not recommended that either of these
parameters is adjusted without consultation
with Manitowoc Beverage Systems
Engineering Department.
1. To adjust the Cut-out temperature:
a. Carefully remove the lens from the front
of the controller.
b. Press and hold the button. Release
after 2 seconds.
c. The display will change from Current
temperature to Current set-point.
d. Adjust the temperature up or down using
the (+) or (-) button.
e. To store the new set-point, scroll through all
menu options to the screen which displays
-
.
--
The controller will then revert to the current
temperature.
f. The display will then show the di erential
temperature. If no di erential adjustment is
necessary, replace the lens. The unit will revert
to the Current Temperature after 30 seconds.
2. To adjust the di erential (cut-in) temperature:
a. Follow steps (a) and (b) above.
b. The display will change from Current
Temperature to Current Set-point.
c. Press and hold the button again.
Release after 2 seconds.
d. The display will change from current
set-point to current di erential.
e. Adjust the temperature up or down
using the (+) or (-) button.
f. To store the new set-point, scroll through all
menu options to the screen which displays
-
.
--
The controller will then revert to the current
temperature.
g. The display will then show the Diagnostic
Mode, or 9999. Ignore this mode. Replace
the lens. The unit will revert to the Current
Temperature after 30 seconds.
Example: If the cut-out temperature is set
at -2.0°C, the di erential must be set to 2.5°C
to cause the unit to cut-in at 0.5°C.