Extron MLC 62 RS CC User manual

Category
Networking
Type
User manual
User Guide
MLC 60 Series
MediaLink
®
MediaLink Controllers
68-2166-01 Rev. E
01 19
Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und
die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di tensione non isolata pericolosa
all’interno del contenitore del prodotto che può costituire un rischio di
scosse elettriche.
ATTENTZIONE: Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di importanti istruzioni di funzionamento
e manutenzione nella documentazione fornita con l’apparecchio.
Per informazioni su parametri di sicurezza, conformità alle normative,
compatibilità EMI/EMF, accessibilità e argomenti simili, fare riferimento
alla Guida alla conformità normativa e di sicurezza di Extron, cod. articolo
68-290-01, sul sito web di Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformować użytkownika o obecności izolowanego i niebezpiecznego
napięcia wewnątrz obudowy produktu, który może stanowić zagrenie
porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji
wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne,
zobacz Extron bezpieczeństwa i regulacyjnego zgodności przewodnik, część
numer 68-290-01, na stronie internetowej Extron, www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению
электрическим током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
www.extron.com, номер по каталогу - 68-290-01.
安全说明 简体中文
警告 产品上的这个标志意在警用户该产品机壳内有暴露的危险 电压,
险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修说明
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 , www.extron.com,参见
Extron 安全规范指南,产品编号 68-290-01
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
安全記事 • 繁體中文
警告: 若產品上使用此符是為了提醒使用者產品機殼內存
可能會導致觸電之風險的未絕緣危險電壓
注意 品上使用此符號,是為提醒使用設備隨附的手冊中有
重要的操作和維(維修説明
有關安全性指導方針法規遵EMI/EMF 相容存取範圍和相主題的詳細
訊,請瀏覽 Extron 網站:www.extron.com然後《Extron 安全性與法規
守手冊準則編號 68-290-01
安全上の注意 日本語
警告: この 製品上に表示されている場合は筐体内に絶縁され
いない高電圧が流れ、感電の危険があるこていま
意:この が製品上に表されている場合はの取明書に
されている重作と保()の示についてユーザーの
を喚起するものです
安全上の注意、法規厳守、EMI/EMF適合性、その他の関連項
スト イト www.extron.com よ り Extron Safety
and Regulatory Compliance Guide』 ( P/N 68-290-01) をご覧ださい。
Copyright
© 2016-2019 Extron Electronics. All rights reserved. www.extron.com
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks (
®
), registered service marks (
SM
), and trademarks (
TM
) are the property of RGBSystems, Inc. or
ExtronElectronics (see the current list of trademarks on the Terms of Use page at www.extron.com):
Registered Trademarks
(
®
)
Extron, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Flat Field, FlexOS, Glitch Free. Global
Configurator, GlobalScripter, GlobalViewer, Hideaway, HyperLane, IPIntercom, IPLink, KeyMinder, LinkLicense, LockIt, MediaLink,
MediaPort, NetPA, PlenumVault, PoleVault, PowerCage, PURE3, Quantum, Show Me, SoundField, SpeedMount, SpeedSwitch,
StudioStation, SystemINTEGRATOR, TeamWork, TouchLink, V-Lock, VideoLounge, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP,
XTPSystems, and ZipClip
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-RateFrameLock), ADSP(Advanced Digital Sync Processing), Auto-Image, AVEdge, CableCover, CDRS(ClassD
Ripple Suppression), Codec Connect, DDSP(Digital Display Sync Processing), DMI (DynamicMotionInterpolation), DriverConfigurator,
DSPConfigurator, DSVP(Digital Sync Validation Processing), eLink, EQIP, Everlast, FastBite, FOX, FOXBOX, IP Intercom HelpDesk,
MAAP, MicroDigital, Opti-Torque, PendantConnect, ProDSP, QS-FPC(QuickSwitch Front Panel Controller), RoomAgent, Scope-Trigger,
ShareLink, SIS, SimpleInstructionSet, Skew-Free, SpeedNav, Triple-Action Switching, True4K, Vector™ 4K , WebShare, XTRA, and
ZipCaddy
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause interference. This interference must be corrected at the expense of the user.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and Regulatory
Compliance Guide on the Extron website.
Battery Notice
This product contains a battery. Do not open the unit to replace the battery. If the
battery needs replacing, return the entire unit to Extron (for the correct address, see the
Extron Warranty section on the last page of this guide).
CAUTION: Risk of explosion. Do not replace the battery with an incorrect type. Dispose
of used batteries according to the instructions.
ATTENTION : Risque d’explosion. Ne pas remplacer la pile par le mauvais type de pile.
Débarrassez-vous des piles usagées selon le mode d’emploi.
VCCI-A Notice
の装置はスA情報技術装置です の装置を家庭環境で使用す電波妨害を引き
があの場合には使用者が適切な対策講ず要求があ
CI-A
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
CAUTION: Risk of minor personal injury.
ATTENTION : Risque de blessuremineure.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
Software Commands
Commands are written in the fonts shown here:
^AR Merge Scene,,0p1 scene 1,1 ^B 51 ^W^C.0
[01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03]
E X! *X1&* X2)* X2#* X2! CE}
NOTE: For commands and examples of computer or device responses used in this
guide, the character “0” is used for the number zero and “O” is the capital letter
“o.”
Computer responses and directory paths that do not have variables are written in the font
shown here:
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32
C:\Program Files\Extron
Variables are written in slanted form as shown here:
ping xxx.xxx.xxx.xxx —t
SOH R Data STX Command ETB ETX
Selectable items, such as menu names, menu options, buttons, tabs, and field names are
written in the font shown here:
From the File menu, select New.
Click the OK button.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
Extron Glossary of Terms
A glossary of terms is available at http://www.extron.com/technology/glossary.aspx.
This Attention box is for
XTP and DTP ONLY,
delete for all others
Delete this entire NOTE if
the above ATTENTION IS
USED FOR XTP AND DTP
PRODUCTS. DELETE the
FIRST paragraph if NOT
TP. The second paragraph
is required if the Attention
is not used (it is duplicate
information).
Delete this entire section if
the product does not have
a battery.
Contents
Configuring the MLC via the USB Port ............... 29
IR Learning ........................................................ 33
Mounting the MLC 60 Series Controllers ........... 34
Mounting the MLC 62 D ............................... 34
Mounting the MLC 64 RS VC D ..................... 36
Mounting the MLC 62 RS EU and the
MLC 62 RS MK ............................................ 38
Mounting the MLC EU in a Raceway Using
Spacers (Optional) ........................................ 39
Accessing Covered Panel Features After
Mounting .......................................................... 41
Accessing the Covered MLC D Front Panel
Features ....................................................... 41
Accessing MLC 62 RS EU and
MLC 62 RS MK Side and Rear Panel
Features ....................................................... 42
Front Panel Security Lockout ............................. 43
Locking Using the Front Panel Buttons ......... 43
Resetting the MLC Using the Reset Button ....... 43
Software-based Configuration ................. 45
About the MLC 55, 62 and 64 Series
Configuration Program ..................................... 45
Computer System Requirements ................... 45
Downloading and Installing the Configuration
Software ........................................................... 46
Starting the Configuration Software ................... 47
Accessing the Help File .................................. 49
Obtaining Device Drivers .................................... 50
Downloading Drivers Using the
Configuration Program ................................. 50
Downloading Drivers from the Web ................ 53
Introduction ...............................................1
About This Guide ................................................. 1
About the MLC 60 Series MediaLink
Controllers .......................................................... 1
MLC Models .................................................... 1
Features .......................................................... 3
Configuration Software .................................... 5
Device Drivers .................................................. 5
Application Diagrams ....................................... 5
System Requirements ......................................... 7
Features, Installation, and Operation ........8
Installation Overview ............................................ 8
Front and Left Side Panels ................................. 10
MLC D Front Panels ...................................... 10
MLC 62 RS EU and MLC 62 RS MK Front
and Side Panels............................................ 12
Front Panel Features ...................................... 12
Buttons.......................................................... 14
Rear Panel Features .......................................... 15
MLC 64 RS VC D Volume Control Module
Rear Panel .................................................... 17
Installation ......................................................... 18
Removing and Replacing the Faceplates ....... 19
Replacing Buttons ......................................... 23
Wiring for RS-232 Control (RS Models
Only) ............................................................. 24
Wiring for IR Control ...................................... 25
Wiring the Relays Port (RS Models Only) ........ 25
Wiring the Digital Input Port (RS Models
Only) ............................................................. 26
Wiring the Remote Port ................................. 27
Wiring the Volume Control Module
(MLC 64 RS VC D Only) ................................ 28
Connecting Power to the MLC....................... 29
viiMLC 60 Series MediaLink Controllers • Contents
SIS Control ...............................................56
Host-to-Controller Communications .................. 56
Controller-initiated Messages ......................... 56
Error Responses ............................................ 56
Using the Command and Response Table ......... 57
Symbol Definitions ......................................... 57
Command and Response Table for SIS
Commands ...................................................... 60
Extron Warranty ....................................... 64
MLC 60 Series MediaLink Controllers • Contents viii
Introduction
This section gives an overview of the guide and describes the MLC 60 Series MediaLink
Controllers and their features. Topics include:
About This Guide
About the MLC 60 Series MediaLink Controllers
System Requirements
About This Guide
This guide provides detailed information and best practice recommendations about cabling
and configuring the Extron MLC 60 Series MediaLink Controllers. It provides reference
information about specifications, dimensions, and programming of the controllers.
Throughout this guide the general terms “MLC” and “controller” are used interchangeably
to refer to any MLC 60 Series controller. “MLC D models” applies to the MLC 62 RS D,
MLC 62 IR D, and the MLC 64 RS VC D. “MLC 62” applies to all MLC 60 Series models
except the MLC 64.
About the MLC 60 Series MediaLink Controllers
The Extron MLC 60 Series MediaLink Controllers are panels that control a wide range of
audio/video systems in any classroom, meeting facility, or auditorium via RS-232 or IR. They
act as extended remote control panels, featuring eight (optionally six) labeled backlit buttons
for the MLC 62 models or six for the MLC 64 RS VC D. These buttons can be configured
via the MLC Windows
®
-based configuration software to control power, input switching, and
volume on a display device or switcher. If desired, you can replace these buttons with ones
having different labels, which also are provided with the controller.
The MLC 64 RS VC D model has, in addition to the configurable buttons, a volume control
module containing an analog volume control knob and a MUTE button. An Extron amplifier
can be connected to this module for volume control via the MLC.
All models can control a projector, display, or switcher via IR. In addition, the MLC 62 RS
models can control display devices, switchers, and various other items such as lights, a
projector lift, or a motorized screen via RS-232, IR, relays, or digital input.
The MLC controllers are housed in secure, compact, one-gang and two-gang sized
enclosures, which can be mounted on a wall or furniture, with or without an electrical
junction box or mounting bracket.
MLC Models
MLC 62 IR D — US model. Controls devices by IR only; has a one-gang decorator-
style faceplate and fits in a one-gang US electrical box.
MLC 62 RS D — US model. Controls devices by RS-232, IR, relays, and digital input;
has a one-gang decorator-style faceplate and fits in a one-gang US electrical box.
MLC 62 RS EU — European model. Controls devices by RS-232, IR, relays, and digital
input; has a one-gang Jung frame and fits over a standard one-gang EU electrical box.
MLC 60 Series MediaLink Controllers • Introduction 1
MLC 62 RS MK — UK model. Controls devices by RS-232, IR, relays, and digital
input; has a standard MK sized frame and fits into a standard one-gang MK electrical
box.
MLC 64 RS VC D — US model. Controls devices by RS-232, IR, relays, and digital
input; has a two-gang decorator-style faceplate and fits in a two-gang US electrical
box. Contains a volume control module with an analog potentiometer for volume
control of an Extron amplifier.
NOTE: Only an Extron amplifier with remote volume control capability can be used
with this model.
VOLUME
Extron
DISPLAY
ON
OFF
VIDEO
PC
VOLUME
Extron
DISPLAY
ON
OFF
PC
VIDEO
LAPTOP
MUTE
MLC 62 IR D MLC 62 RS D
Extron
VOLUME
DISPLAY
ON
OFF
LAPTOP MUTE
PC VIDEO
Extron
VOLUME
DISPLAY
ON
OFF
VIDEO
PC
MUTE
LAPTOP
MLC 62 RS EU MLC 62 RS MK
AUX
LAPTOP
PC
MUTE
Extron
DISPLAY
VOLUME
ON
OFF
VIDEO
MUTE
V
O
LUM
E
MLC 64 RS VC D
Figure 1. MLC 60 Series Models
MLC 60 Series MediaLink Controllers • Introduction 2
The five MLC models have the same button functionality and use the same configuration
software. All models can be controlled by pressing the front panel buttons or via a host
device using RS-232 communication and simple ASCII commands (Simple Instruction Set
or SIS). They differ from each other in the following ways:
The MLC 62 IR D rear panel does not contain the Relay, Digital Input, or RS-232
control ports that the RS models have.
The MLC 64 front panel has seven buttons, one of which (the MUTE button) is located
below the VOLUME knob. This button is used only to mute and unmute the volume on
an Extron amplifier and cannot be configured to perform other functions.
Some front, side, and rear panel connectors are located in different places on the
MLC RS D (US), EU (Europe), and MK (United Kingdom) models (see Front and Left
Side Panels on page 10).
Faceplate alternatives
The MLC 60 Series models are available with the following faceplate configurations:
MLC 62 IR D — The US IR model is delivered with two six-button faceplates in black
and white. One black and one white decorator-style wallplate are also provided. An
eight-button faceplate is available to order.
MLC 62 RS D — The US RS-232 model is delivered with two eight-button faceplates
in black and white. One black and one white decorator-style wallplate are also
provided. A six-button faceplate is available to order.
MLC 62 RS EU — The European model is delivered with six-button and eight-button
faceplates, in black or white.
MLC 62 RS MK — The UK model is delivered with six-button and eight-button
faceplates, in white.
MLC 64 RS VC D — The MLC 64 is delivered with seven-button faceplates in black
and white.
Features
Customizable buttons — Eight buttons are standard on the MLC 62 RS models,
prelabeled as shown in figure 1 on the previous page. The MLC 62 IR D has six
prelabeled buttons, and the MLC 64 RS VC D has seven.
An additional set of prelabeled buttons is included with each model, enabling the
controller to be customized to suit the application.
Additional buttons are available to order for all models, labeled in English (the default)
and other languages. Buttons can be ordered with custom labeling as well.
Button backlighting — The front panel buttons are backlit to facilitate use in
low-light environments and to provide certain status (such as whether power is on or
off, or which input has been selected).
Alternative six-button configuration (MLC 62 RS models only) — For
applications in which input device or button functions are not necessary, the standard
eight-button faceplate on the MLC 62 RS can be replaced with a six-button one.
Each pair of source selection buttons can be changed to a long, single function
button.
Device drivers — A wide variety of Extron certified, ready-to-use device drivers are
available via the MLC configuration software and the Extron website.
MLC 60 Series MediaLink Controllers • Introduction 3
IR and RS-232 ports — The MLC 64 and the MLC 62 RS models each have a
dedicated serial port for communicating with most types of projectors or flat panel
displays via unidirectional RS-232. They also have an IR/S port, which can be
configured for IR or RS-232 control.
The MLC 62 IR D has only an IR port, which is used for IR communication only.
IR and RS-232 display drivers can be downloaded and used to configure the
controller.
Relays (RS models) — Two relay ports enable control of room devices such as lights,
motorized screens, and projector lifts.
Digital Input (RS models) — A Digital Input port enables monitoring of a switch or
sensor to control devices.
IR Learning — The MLC can be configured by IR learning, using the remote control
of a switcher or display device to create an IR driver that enables the MLC to control
the device.
USB configuration port — The MLC can be configured via a USB mini B port,
located on the front or side panel (depending on the model). This port can also
temporarily provide power to the MLC during configuration.
Volume adjustment:
The MLC 62 models have individual Volume Up and Down buttons for audio
level control, with five LEDs that indicate current audio settings.
The MLC 64 has a volume control module with an analog potentiometer knob to
control the audio level for an Extron amplifier that is enabled for remote volume
control. The volume control module also contains a MUTE button for muting and
unmuting the audio (this button cannot be reprogrammed).
NOTE: Only Extron amplifiers can be controlled via the MLC 64 volume
control module.
Macro capability — Each button can be configured to execute multiple actions
through the serial or IR control ports. For example, a button can be configured so that
a single press triggers commands to turn on a display, select the RGB input of the
display, and trigger a relay.
Toggling — Buttons can be placed in toggle mode, which adds flexibility by enabling
two different sets of commands to be executed with alternating presses of the button.
Built-in speaker — A speaker provides audible feedback to confirm user actions
when buttons are pressed (except for the MUTE button on the VCM module of the
MLC 64 RS VC D).
Inactivity timer for display shutoff — An adjustable timer controls automatic
shutdown after a specified period of inactivity.
Front panel security lockout — If the MLC is installed in an unsecured environment
where easy access is not desirable, a security lockout feature can be implemented to
lock out all front panel controls.
Activity LED — A small LED at the top of the MLC front panel lights red, green,
or amber to indicate button presses, data transfer, front panel lockout, and other
actions.
Section 508 Compliant — The MLC meets or exceeds accessibility standards
for Electronic Information Technology. For more information about the Extron
Commitment to Accessibility, see the Extron Accessibility web page at
www.extron.com/company/article.aspx?id=accessibility.
MLC 60 Series MediaLink Controllers • Introduction 4
Configuration Software
The MLC 55, 62 and 64 Series Configuration Program is used to configure the MLC
buttons and ports via an RS-232 or USB connection. This software, available for
download from the Extron website, enables you to set functions for the front panel
buttons and to configure the MLC ports in order to control devices via the MLC.
The software works in combination with the IR or RS-232 drivers, also provided at
www.extron.com (see Downloading and Installing the Configuration Software on
page 46 to access this program).
Device Drivers
The MLC can control a switcher, projector, or other display device via IR or RS-232
communication. The MLC must have drivers loaded for the devices it will control in order
to send commands to those devices. Drivers can be obtained in the following ways:
You can download IR or RS-232 driver files from Extron via the driver subscription
feature within the MLC configuration program. The drivers are saved on your
computer in a folder located at c:\Documents and Settings\All Users\Shared
Documents\Extron\Driver2 or at c:\Users\Public\Documents\Extron\
Driver2. You can upload the desired drivers to the MLC using the MLC configuration
software.
You can capture IR commands from the IR remote control of a device through
IR Learning using the MLC configuration program to create a driver that the MLC
can use. When a driver is created, it can be added to the configuration program so
that the commands can be used to configure the MLC to control the device (see the
MLC 60 Series Help file to configure the MLC using IR Learning).
Application Diagrams
RS-232/
MLC/IR
Tx
RxIR
12
V
A
B
C
PR
EAM
P
1
0
0
-24
0
V
1
.
0
A M
A
X.
5
0
-6
0
Hz
4
AUDIO
INPUTS
LINE LEVEL
M
ONO
A
UDIO
AUDI
O
LINEOUT
AUX/MIX
ADJUST
-42dB
TO
+
2
4
dB
L
R
L
R
L
R
1
2
3
INP
UTS
O
UTP
UTS
VI
DEO
H
V
B
G
R
Y
1
2
3
I
NPUTS
MONITOR OUT
4
5
6
C
L
R
L
R
L
R
AMPLIFIED OUTPUT
R
IGHT
LEFT
R
PC
RGBHV
RGBHV
and
Audio
Laptop
w/ Audio
S-video
Video
Audio
Audio
Video
Video
Extron
MLS 406SA
MediaLink
®
Switcher
Document Camera
VCR
DVD
Projector
RGBHV
RS-232
Switcher
Control
RS-232 or
IR Projector
Control
Extron
MLC 62 RS D
MediaLink™ Controller
VOLUME
DISPL
AY
ON OFF
PC
VID
EO
LAPTOP
MUTE
Extron
SM 3
Full
-Range
Speakers
Figure 2. MLC 62 RS D Controlling an MLS 406SA Switcher and a Projector
MLC 60 Series MediaLink Controllers • Introduction 5
VOLUME
DISPLAY
PC
VIDEO
ON
OFF
PC
DVD
Projector with
Internal Speakers
IR Projector Control
V
ideo
VGA
Audio
Audio
IR Display Control
On/Off Control
Input Switching
Volume Control
Extron
MLC 62 IR D
MediaLink
Controller
Figure 3. MLC 62 IR D Controlling a Projector
Projector
with Switched
Audio Output
Screen
Control
PC
Relay
Extron
SM 3
Full-Range
Speakers
RS-232
Display Control
DVD
Video
Laptop
Audio
VGA
Audio
Audio
VGA
Extron
MPA 152
Mini Power
Amplier
BASS
LEVEL TREBLE
MINI POWER AMPLIFIER
MPA 152
STEREO
DUAL
MONO
DISPLAY
VOLUME
LAPTOP MUTE
PC VIDEO
ON OFF
Extron
MLC 62 EU
MediaLink
Controller
Figure 4. MLC 62 RS EU Controlling a Projector and Screen
MLC 60 Series MediaLink Controllers • Introduction 6
POWER
12V
0.7A MAX
L
R
L
8Ω / 4Ω
CLASS 2
WIRING
R
10V
V
C
G
50mA
L
MPA 152 Plus
R
INPUTS
OUTPUTS
REMOTE
Projector
with Switched
Audio Output
Screen
Control
PC
Relay
Extron
MLC 64 RS VC D
MediaLink Controller
Extron
SM 3
Full-Range
Speakers
RS-232
Display Control
Volume Control
DVD
Video
Laptop
Audio
VGA
S-video
Audio
Audio
VGA
Extron
MPA 152 Plus
Power
Amplier
MUTE
VOLUME
DISPLAY
OFF
ON
VIDEO
AUX
LAPTOP
PC
Document
Camera
Figure 5. MLC 64 RS VC D Controlling an Amplifier, a Projector, and a Screen
System Requirements
The minimum PC system requirements for installing the configuration software include:
Intel
®
Pentium
®
III 1-GHz processor
Microsoft
®
Windows XP SP2, Windows 7, Windows 8, or Windows 8.1
Microsoft.NET Framework 2.0
512 MB of RAM
50 MB of available hard disk space
MLC 60 Series MediaLink Controllers • Introduction 7
Features,
Installation, and
Operation
This section describes the front, side, and rear panel features of the five MLC models, and
provides procedures for installing and operating them. Topics include:
Installation Overview
Front and Left Side Panels
Rear Panel Features
Installation
Configuring the MLC via the USB Port
Mounting the MLC 60 Series Controllers
Accessing Covered Panel Features After Mounting
Front Panel Security Lockout
Resetting the MLC Using the Reset Button
IR Learning
Installation Overview
1. Prepare the installation site as follows:
a. Measure and cut the hole in the mounting surface (see Mounting the MLC 60
Series Controllers, beginning on page 34).
b. Prepare and pull the cables through the electrical box or mounting bracket.
c. Install the electrical box or mounting bracket. (Installation instructions for the
electrical box are provided with it.)
2. (Optional) Make desired changes to the buttons installed in the faceplate, substituting
any of the provided additional buttons (see Replacing Buttons on page 23).
NOTE: The MUTE button on the MLC 64 volume control module cannot be
changed.
MLC 60 Series MediaLink Controllers • Features, Installation, and Operation 8
3. Attach the cables to the rear panel connectors of the MLC and to the display device
or switcher. Attach optional IR Emitters if used, and any switches or sensors needed
for other room devices, such as lights, a motorized screen, and so forth). See the
following sections as needed for cabling information:
Rear Panel Features
Wiring for RS-232 Control (RS Models Only)
Wiring for IR Control
Wiring the Relays Port (RS Models Only)
Wiring the Digital Input Port (RS Models Only)
4. Wire and connect the MLC power supply (see Connecting Power to the MLC on
page 29). Connect all other power cords and turn on all the devices, including the
MLC.
5. Connect a configuration cable from the computer to the MLC by doing either of the
following:
Connect a USB A to mini B cable to the MLC USB configuration port and to a
USB port on your computer (see Configuring the MLC via the USB Port on
page 29).
Wire an RS-232 cable to the provided 3-pole connector, and connect the cable
between the MLC Remote port and the computer serial port (see Wiring the
Remote Port on page 27).
6. Download and install the MLC Configuration Program (see Downloading and
Installing the Configuration Software on page 46).
7. Download or create drivers for the devices you will be connecting (see Obtaining
Device Drivers on page 50 or IR Learning on page 33).
8. Configure the MLC buttons and ports using the configuration program. (See the
configuration program help file for these procedures. To access the help file, see
Downloading and Installing the Configuration Software).
If you are configuring via the USB port, remove the USB cable when you are finished.
9. Test the system: press the MLC buttons, watch the display, and listen to the audio
output to determine whether the connected devices are responding correctly
(powering on and off, switching inputs, and so forth). If not, ensure all devices are
plugged in and receiving power. Check the cabling and make needed adjustments.
10. Disconnect power from the MLC at the source and from all other devices in the
system.
11. Mount the MLC to the mounting surface, following the appropriate procedure for your
MLC model:
For MLC 62 D models, see Mounting the MLC 62 D on page 34.
For MLC 62 RS EU and MK models, see Mounting the MLC 62 RS EU and
the MLC 62 RS MK on page 38.
For the MLC 64, see Mounting the MLC 64 RS VC D on page 36.
12. Restore power to the MLC and to the connected devices.
MLC 60 Series MediaLink Controllers • Features, Installation, and Operation 9
Front and Left Side Panels
MLC D Front Panels
The front panels of the MLC 62 RS D, the MLC 62 IR D, and MLC 64 models contain
buttons and indicators that are visible and accessible after the MLC has been mounted.
Other front panel controls and connectors are located behind the MLC wallplate and are
not visible after mounting (see Controls behind the wallplate on the next page).
MLC 62 D front panels
By default, the MLC 62 RS D has eight front panel buttons, and the MLC 62 IR D has six.
Both models also have indicator LEDs for volume and activity.
DD
D
D
C
C
B
B
A
A
VOLUME
DISPLAY
ON
OFF
PC
VIDEO
LAPTOP
MUTE
Extron
VOLUME
Extron
DISPLAY
ON
OFF
VIDEO
PC
MLC 62 RS D
MLC 62 IR D
EE
A
Activity LED
B
Display power On and Off Buttons
C
Volume buttons and LEDs
D
Input Selection buttons
E
ON button identification nub
Figure 6. MLC 62 RS D and MLC 62 IR D Front Panels
MLC 60 Series MediaLink Controllers • Features, Installation, and Operation 10
MLC 64 RS VC D front panel
The MLC 64 RS VC D front panel contains seven buttons, an Activity LED, and a volume
control knob.
AA
B
B
D
D
G
G
F
F
VIDEO
AUX
LAPTOP
PC
Extron
DISPLAY
ON
OFF
MUTE
VOLUME
MUT
E
V
O
L
U
M
E
EE
A
Activity LED
B
Display power On and Off Buttons
D
Input Selection buttons
E
ON button identification nub
F
MUTE button
G
Volume control knob
Figure 7. MLC 64 RS VC D Front Panel
Controls behind the wallplate
The front panels of the MLC D controllers contain some controls and connectors that are
located behind the wallplate when the controller is mounted. To access these features that
are covered during normal operation, you must remove the wallplate (see Accessing the
Covered MLC D Front Panel Features on page 41).
KK
J
J
HH
VOLUME
DISPLAY
E
PC
VIDEO
LAPTOP
MUTE
ON
OFF
MUTE
VOLUME
E
VO
L
U
ME
AUX
LAPTOP
PC
E
DISPLAY
ON
OFF
VIDEO
MLC 62 RS D
MLC 64 RS VC D
II
H
Reset LED
I
Reset button
J
USB configuration port
K
IR Learning sensor
Figure 8. MLC D Front Panel Controls Behind the Wallplate
MLC 60 Series MediaLink Controllers • Features, Installation, and Operation 11
MLC 62 RS EU and MLC 62 RS MK Front and Side Panels
The MLC 62 RS EU and MLC 62 RS MK front panels contain the same buttons and
indicators as the MLC 62 D models. Other connectors and controls are on the left side
panel. To access these features, you must remove the MLC from the installation surface.
When the MLC is removed, the wall frame is released from the mounting surface as well,
leaving the metal mounting bracket in place (see Accessing the MLC 62 RS EU and
MLC 62 RS MK Side and Rear Panel Features on page 42 for removal procedures).
CC
A
A
VOLUME
DISPLAY
LAPTOP MUTE
PC VIDEO
ON OFF
E
BB
DD
EE
KK
JJ
A
Activity LED
B
Display power On and Off Buttons
C
Volume buttons and LEDs
D
Input Selection buttons
E
ON button identification nub
J
USB configuration port
K
IR Learning sensor
Figure 9. MLC 62 RS EU and MLC 62 RS MK Front and Side Panels
NOTE: The MLC 62 RS MK is the same size and has the same front and side panel
features as the MLC 62 RS EU, with the exception of its larger wall frame, which fits over
an MK electrical box.
Front Panel Features
A
Activity LED — This bicolored LED lights green when the MLC front panel buttons
are pressed. It blinks red while enabling front panel lockout (executive mode).
B
Display power On and Off buttons — After configuring these buttons, use them to
turn the connected display device or switcher on and off.
The face of the ON button contains a nub (
E
), which helps you to identify the button
by touch. When the ON button is pressed, it blinks rapidly while the connected device
is warming up. When the OFF button is pressed, it blinks slowly while the device
is cooling down. When this delay period has elapsed, the power button that was
pressed remains brightly lit. By default, only one of these two buttons can be selected
(active) at a time. Using the MLC configuration software, you can associate other
functions and relays with each of these buttons (see the MLC 60 Series Help file).
C
Volume buttons and LEDs (MLC 62 models only) — Use these buttons to adjust
the audio volume. Each VOLUME button blinks when pressed and continues to blink
while being held. The volume indicator LEDs above the buttons give indications of
change to the volume level as follows:
When the RS-232 or IR/S port has been configured with a serial driver that
contains a volume table, the five LEDs light in order from left to right to show
volume level increments.
If the current driver does not contain a volume table, the first two LEDs on the left
blink each time the VOLUME Down button is pressed, and the last two LEDs on the
right blink each time the VOLUME Up button is pressed, indicating a volume level
decrement or increment.
MLC 60 Series MediaLink Controllers • Features, Installation, and Operation 12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Extron MLC 62 RS CC User manual

Category
Networking
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI