Zamel EXTA FREE RNK-04 Manual Instruction

Category
Wall transmitters
Type
Manual Instruction
RZB-04 WIRELESS CONTROL SET
- LIGHTING, 2-CHANNEL MANUAL INSTRUCTION
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: [email protected]
VER. 003_20.05.2011
APPEARANCE
FEATURES
TECHNICAL DATADESCRIPTION
●completesetofwirelesscontrol(4–chan-
nel button radio transmitter RNK-04 and
2-channelradioflushreceiverROP-02).
●2outputrelays(drycontacts230VAC),
●lighting, heating operation control, other
receiverscontrol,
●easyushinstallationØ60mm,
●5operationmodes:switchingon,switch-
ing off, monostable mode, bistable mode,
timemode(switchoffdelay),
●wideoperationrange(upto200m),
●operationisopticallysignalled,
●low current consumption, possibility of
constant operation,
●possibility of increasing operation range
by means of RTN-01 retransmitter.
Radio ush receivers are used both as
elements in mounting in ush and surface
installation cable boxes and as an actuator
built directly in lighting tting casings and
other receivers). ROP-02 enables operation
in5differentmodes(switchingon,switching
off, monostable mode, bistable mode, time
mode.
RNK-04 ROP-02
Input (supply) terminals: - L, N
Inputratedvoltage: 3 V DC (CR2032 battery) 230 V AC
Battery life: 3 ÷ 5 years -
Inputvoltagetolerance:
-
-15 ÷ +10 %
Nominal frequency:
-
50 / 60 Hz
Nominalpowerconsumption: - 0,39 W („stand-by” mode) / 0,69 W
operationmode1channel/1,09W
operationmode2channels
Number of operation modes: - 5
Numberofchannels: 4 2
Transmission: radio 868,32 MHz
Codingway: unidirectional
Coding:: addressing transmission
Maximum number of remote controls: - 32
Range: upto250mintheopenarea
Time adjustment: - 1sec÷18hours(every1sec)
Optic signalling of transmitter’s operation: LED red diode
Input terminals: - IN1, IN2
Transmitter’s input (supply) terminals: - OUT1,OUT2(voltagecontacts)
Relay contact parameters: - 2NO 5A / 250V AC AC1 1250 VA
Number of terminal clamps: - 6
Section of connecting cables: - up to 2,5 mm2
Ambient temperature range: -10 ÷ +55 oC
Operating position: free
Casing mounting:
wall plugs, double-sided adhesive tape
installationcableboxØ60mm
Casing protection degree: IP20 (EN 60529)
Protectionlevel: III II
Overvoltagecategory: - II
Pollution degree: - 2
Surgevoltage: - 1 kV (EN 61000-4-5)
Dimensions: 90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm
Weight: 0,038 kg 0,039 kg
Reference standard: ETSI EN 300 220-1,
ETSI EN 300 220-2
EN 60669, EN 60950,
EN 61000
Opticsignallingofreceiver’soperation
Programmingpush-button
Input terminals (IN1, IN2)
Output terminals (OUT1, OUT2)
Input (supply) terminals (L, N)
Optic signalling
of transmitter’s operation
Push-buttons
The device is designed for
single-phase installation and
must be installed in accord-
ance with standards valid in
a particular country. The de-
vice should be connected
according to the details in-
cluded in this operating manual. Installation,
connectionandcontrolshouldbecarriedoutby
aqualiedelectricianstaff,whoactinaccord-
ance with the service manual and the device
functions.
Incaseofcasingdismantlinganelectricshock
mayoccur,andtheguaranteeislostthen.Be-
foreinstallationmakesuretheconnectionca-
blesarenotundervoltage.Thecruciformhead
screwdriver3,5mmshouldbeusedtoinstalthe
device. Improper transport, storage, and use
of the device inuence its wrong functioning.
 It is not advisableto instalthe device in the
followingcases:ifanydevicepartismissingor
thedeviceisdamagedordeformed.Incaseof
improperfunctioningofthedevicecontactthe
producer.
CAUTION!
The symbol means selective
collecting of electrical and electronic
equipment.
It is forbidden to put the used
equipment together with other waste.
WARRANTY CARD
Thereis24monthsguaranteeontheproduct
1. ZAMELprovidesatwo-yearwarrantyforitsproducts.
2. TheZAMELwarrantydoesnotcover:a)mechanicaldefects resultingfromtransport,loading/unloadingorothercircumstances
b)defectsresultingfromincorrectinstallationoroperationofZAMELproducts;c)defectsresultingfromanychangesmadebyCUS-
TOMERSorthirdparties,toproductssoldorequipmentnecessaryforthecorrectoperationofproductssold;d)defectsresulting
fromforcemajeureorotheraleatoryeventsforwhichZAMELisnotliable;e)powersupply(batteries)tobeequippedwithadevice
inthemomentofsale(iftheyappear);
3. AllcomplaintsinrelationtothewarrantymustbeprovidedbytheCUSTOMERinwritingtotheretailerafterdiscoveringadefect.;
4. ZAMELwillreviewcomplaintsinaccordancewithexistingregulations.;
5. Thewayacomplaintissettled,e.g.replacementoftheproduct,repairorrefund,islefttothediscretionofZAMEL.
6. Guaranteedoes not exclude, does not limit, nor does it suspend therightsofthe PURCHASER resulting from the discrepancy
betweenthegoodsandthecontract.
Salesman stamp and signature, date of sale
CONNECTION
APPLICATION
CAPACITY
750W
250W
500W
375W
ROP-02 MOUNTING
1.Disconnectpowersupplybythephasefuse,
thecircuit-breakerortheswitch-disconnector
combinedtothepropercircuit.
2. Check if there is no voltage on connec-
tion cables by means of a special measure
equipment.
3.Connectthecableswiththeterminalsinac-
cordancewiththeinstallingdiagram.
4.InstallROP-02deviceininstallationcablebox.
5.Switchonthepowersupplyfromthemains.
RNK-04 FUNCTIONING, MOUNTING
Bypressingthebutton,thetransmittersends
asignalwith868,32MHzfrequencywhichcon-
trolsEXTAFREEreceivers.Device program-
ming procedure (adding a transmitter to
a receivers memory) is described in par-
ticular EXTA FREE manual instructions.
Thedevicerange(upto250mdependingon
areceiver)canbeincreasedbymeansofare-
transmitterorfewRTN-01retransmitters.The
devicecanbemountedinanyplacebymeans
ofdouble-sided adhesive tape orwall plugs
5 x (3 x 30) mm.
Mountingbymeansofwallplugs:
1.Removethebutton- todoitpressthebut-
ton on one side, and on the other side put
ascrewdriverintoaslotandliftupthebutton.
2. Find a place on the wall to mount the
transmitter, make two holes corresponding
mountingholesfromthetransmitter’sbase.
3.Setwallplugsintheholes.
4.Fixthebasebymeansofscrewingscrews
intowallplugs.
5.Placethebuttonagain.
BATTERY CHANGE
Battery discharge status is signalled by
several LED red diode ashes during
transmission time.
1.Removethebutton(mounting-point1).
2. By means of a screwdriver lever up the
printed-circuit board releasing the bottom
latchandremoveitfromthebase.
3.Removethebatteryfromthelatch.
4.Mountanewbattery.Watchbatterypolari-
sationmarkedonthelatch.Wrongbattery
mountingmaycausedevicedamage.
5.Puttheremovedprinted-circuitboardback
inthebase.
6.Putbackthebutton.
CAUTION: While changing the battery,
it is suggested to press any of the buttons
for about 5 seconds before putting it into
a latch. Next press transmission button
several times to check its operation. If the
transmitter does not work properly repeat
the battery change procedure.
2-channelradioushreceiverROP-02
operatesasareceiverof8-channelremote
controllerP-256/8andof4-channelbutton
radiotransmitterRNK-04(lightsources
switchon/switchoffcontrol).Theabove
mentioned transmitters can also control
operationofradiolightingswitchRWL-01
and remote control socket RWG-01.
TheZAMELcompanydevices
whicharecharacterised
withthissigncancooperate
witheachother.
VER. 003_20.05.2011
ROP-02 OPERATION
ROP-02canoperateinvemodesforeverychannel:
MONOSTABLE
the relay operates only
while pressing transmit-
ter’spush-button.
BISTABLE
(one push-button) the
device changes relay
statuscyclicallyalways
after pressing the same push-
button.
SWITCH ON
the device switches on
afterpressingthepush-
button.
SWITCH OFF
the device switches off
afterpressingthepush-
button.
TIME
the device switches
off according to the
adjusted time (tp),
butitmaybeswitchedoffbefore
adjusted time nishes. Default
settings - 15 seconds.
CAUTION! Adjusted time can
not be deleted.
RADIO TRANSMITTERS PROGRAMMING - CHANNEL 1
TIME PROGRAMMING
RADIO TRANSMITTERS PROGRAMMING - CHANNEL 2
RADIO TRANSMITTERS DELETION
COOPERATION AND OPERATING RANGE
Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01
RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m
RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m
RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m
RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
*-1-channeltransmittersdonotcooperatewithrollerblindcontrollers.
CAUTION: The given range concerns open area - an ideal condition without any natural or articial obstacles. If there are some obstacles between a transmitter and a receiver,
it is advisable to decrease the range according to: wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100% ,
glass: from 10 to 20 %, Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have
also a negative inuence on the range.
MONOSTABLE mode:
BISTABLE mode:
SWITCH ON/SWITCH OFFmode(twopush-buttons):
TIMEmode(onepush-button):
AnexemplaryprogrammingprocedurewiththeuseofP-257/2remotecontroller.TheprocedurefortherestofradioEXTAFREEtransmitters
is analogous. CAUTION: Every transmitter can cooperate with ROP-02 in a different mode, depending on how they were added to
the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode.
Press transmitter’s
push-buttonfor
a longer time.
Pressthetransmitter’spush-button
for a longer time. LED red diode
switcheson(rstsignalpulsates,
nextthesignalisconstant).
PressPROGpush-buttonofROP-01
deviceandthenreleaseit.LEDreddiode
switcheson(rstsignalpulsates,
nextthesignalisconstant).
Pressandreleasetransmitter’srst
push-button.LEDreddiodeswitcheson
(rstsignalpulsates,
nextthesignalisconstant).
Releasetransmitter’spush-
button.LEDreddiodeswitches
on(rstsignalpulsates,next
thesignalisconstant).
Release transmitter’s
push-button.LEDreddiodeswitches
on(thesignalpulsates),nexttheLED
reddiodeswitchesoff-itmeansthe
TRANSMITTER IS ADDED.
Pressandreleasethesametransmitter’s
push-buton.LEDreddiodeswitcheson
(signalpulsates)andthenswitchesoff-
THE TRANSMITTER IS ADDED.
Pressandreleasethesecondtransmitter’s
push-button.LEDreddiodeswitcheson
(thesignalpulsates)andnextitswitches
off - THE TRANSMITTER IS ADDED.
Pressthesametransmitter’spush-
-button and release it. LED red
diodeswitcheson(thesignalpulsa-
tes)andnextitswitchesoff-THE
TRANSMITTER IS ADDED.
PressPROGpush-buttonofROP-02device
foralongertimeuntilLEDreddiodeswitcheson
(constantsignal).NextreleasePROGpush-button.
PressPROGpush-buttonofROP-02device
for a longer time until LED red diode
switcheson(constantsignal).
NextreleasePROGpush-button.
PressPROGpush-buttonofROP-02device
for a longer time until LED red diode
switcheson(constantsignal).
NextreleasePROGpush-button.
PressPROGpush-buttonofROP-02device
for a longer time till LED red diode
switcheson(constantsignal).
NextreleasePROGpush-button.
CAUTION: Forthemonostablemode,pressthebuttonontheremotebeforepressingPROGpush-button.
Wait again (for about 5 seconds) till
LEDreddiodeswitcheson(rstsignal
pulsates,nextthesignalisconstant).
Waitagain-thirdtime(forabout5
seconds) till LED red diode
switcheson(rstsignalpulsates,
nextthesignalisconstant).
Aftertheadjustedtimeisnished(the
numberofLEDreddiodeashes)press
PROGpush-buttonandthenreleaseit-
TIME IS ADDED.
Aftertheadjustedtimeisnished
(thenumberofLEDreddiodeashes)
pressPROGpush-buttonandthen
release it - TIME IS ADDED.
PressPROGpush-buttonofROP-02deviceand
thenreleaseit.LEDreddiodeswitchesoffand
thenswitcheson(signalpulsates).EveryLED
diode pulse equals 1 second.
for
CHANNEL 1
for
CHANNEL 2
PressPROGpush-buttonofROP-02device
andthenreleaseit.LEDreddiodeswitchesoff
andthenswitcheson(signalpulsates).Every
LED diode pulse equals 1 second.
Maximumtimeis18hours.
PressPROGpush-buttonofROP-02deviceforalongertimetillLEDreddiodeswitcheson
(constantsignal).NextreleasePROGpush-button.Wait(forabout5seconds)tillLEDred
diodeswitcheson(rstsignalpulsates,nextthesignalisconstant).
PressPROGpush-buttonofROP-02deviceforalongertimeuntilLEDreddiodeswitches
on(constantsignal).NextreleasePROGpush-button.Wait(forabout5seconds)tillLEDred
diodeswitcheson(rstsignalpulsates,nextthesignalisconstant).
ChooseoneofROP-02veoperationmodes
andprogrammethedeviceinthesamewayas
forchannel1.
PressPROGpush-buttonofROP-02device
for a longer time.
After5secondsLEDreddiodeswitcheson
(signalpulsates)andthenitswitchesoff.
Releasethepush-buttoninROP-02-
MEMORY IS DELETED.
1s 2s ns