Range of application for the pressure transmitter type 8316
Thepressuretransmitterisusedtomeasurerelativeandabsolutepressureofliquidandgases.
Thepressuretransmitterconsistsofapiezoresistivemeasuringcellwithadiaphragm,installedinastainless
steel housing. This transmitter is available with various connector types, IP protection standards as well as
current- and voltage outputs.
Installation
• Thelocationofthedevicehasnoinfluenceontheprecisionofthemeasurement.
• Beforeinstallation,comparetheprocessdatawiththedataofthenameplate.
• Themediumbeingmeasuredmustbesuitableforthepartsofthepressuretransmitterincontactwiththe
medium.
• Connectthedevicestoafixedcableinstallation.
• Thedevicesmayonlybeinstalled,connected,set-upandoperatedbyqualifiedstaffandincompliancewith
thetechnicalspecifications.
• TheeffectsofUVradiationcancausematerialstobecomebrittle.Protectthedevicefromdirectsunlight.
Safety instructions
Intermsofasafety-instrumentedsystem,thisdeviceleftthefactoryinperfectcondition.Tomaintainthisstatus
andtoensuresafeoperationofthedevice,observethefollowingnotes:
Thedevicemayonlybeusedforthepurposesspecifiedintheseinstructions.
• Whenconnectingup,installingandoperatingthedevice,thedirectivesandlawsofyourcountryapply.
• Thedeviceisnotusedproperly,seriousbodily injuryand/or considerabledamage topropertycannot be
excluded.Thisshouldbekeptinmindparticularlywhenthedevicewasinuseandisreplaced.
• Thetransmitterispresettothespecificmeasuringrangeatthemanufacturer’splant.Anadditionalsetting
is not possible.
• Theoverloadlimitshouldbemonitoredandkepttoatalltimes.
• Thetransmitterismaintenance-free.
• Connectthedevicetoalowvoltagepowersupplywithsafeseparation(SELV).
• ForequipmentwithaULmark,theymustbesuppliedwithlimitedenergyaccordingtoUL61010-1Second
Edition,Section 9.3 or LPS in conformance with UL60950-1 or class 2 in compliance with UL1310 or
UL1585.
Tests / Admissions
Electromagneticcompatibility: CEconformityacc.EN61326-2-3
ULrecognizedcomponentmarks: acc.E312665
Shockacc.IEC60068-2-27: 25g,6mshalfsinewave,all3directions.
DroptestEN60068-2-23: from1monconcrete
Vibrationacc.IEC60770-1: 5m/s,10...1000Hz,1Octave/min20constantloadperaxis