3
ATTENTION:
• Do not connect any external power supplies until you have read the Attention notications in the Power Supply
section of the user guide for that device.
• Ne branchez pas de sources d’alimentation externes avant d’avoir lu les mises en garde dans la section
«PowerSupply» du guide utilisateur pour cet appareil.
7
Connect the StudioStation100 LAN port to the IPL T PC1 LAN port (see figure 1 on page 1) using the included NETXC
M-M 6 foot (1.8 meter) RJ-45 network crossover cable to enable the IPL T PC1 to power on and off the connected recording
equipment such as the camera, studio lights, and microphone, when a USB drive is inserted into the RCP101 EU USB port.
• If the crossover cable is used, no further conguration is required.
• If a straight-through cable is used and the StudioStation and PC1 are connected through a network, follow these
conguration steps:
a. Congure the IP address of the IPL T PC1 via the embedded web page.
• If you do not know the IP address, use the IP Link Device Manger to discover it.
• The default IP address of the IPL is 192.168.254.254.
b. Assign an Admin password to the IPL T PC1 (optional).
c. From the StudioStation100 Web UI, on the StudioStation page, enter the IP address and the Admin password
(if required) of the IPL T PC1 and test the connection (see gure 4).
• In order to enter the Web UI of the StudioStation 100, you need the IP address of the StudioStation 100.
• The default IP address of the StudioStation 100 is 192.168.254.253
Figure 4. Test Connection on the StudioStation Page
8
Connect the IEC power cable from the lights into the IEC Power outlet of the IPL T PC1 to automatically power the lights on
and off when a USB drive is inserted into the USB port on the RCP101 EU.
9
Connect an optional HDMI display into the HDMI output to preview the recording.
¢
Connect the provided IEC cables:
a. Into the IPLTPC1 and a power source.
b. Into the StudioStation100 and a power source.
c. Verify the front panel buttons and LCDs illuminate.
£
Insert a USB drive into the USB port on the RCP101 EU.
a. The StudioStation100 detects the USB drive inserted into the RCP101 EU and sends a command to the IPLTPC1 to
turn on the power outlet.
NOTE: By default, the StudioStation100 records to the RCP101 EU USB drive.
b. The IPL T PC1 powers ON the attached recording devices.
NOTE: When the USB drive is removed from the RCP101 EU, the Studio Station 100 sends a command to turn OFF the
IPLTPC1 power output. All attached recording devices are powered OFF.
¤
Configure the StudioStation 100 (optional). Configuration is only available when connected through a network.
a. Congure the metadata on the Metadata page (see gure 5) in the StudioStation100 Web UI.
Figure 5. Configure Metadata on the Encoding & Metadata Page